Related papers: Continuous phase amplification with a Sagnac inter…
We examine the effect of different sources of technical noise on inverse weak value-based precision phase measurements. We find that this type of measurement is similarly robust to technical noise as related experiments in the weak value…
We show that by injecting a light pulse prepared in a non-Gaussian quantum state into the dark port of a two-arm interferometer, it is possible to detect a given phase shift with the fidelity which is limited only by the optical losses and…
Achieving higher sensitivity is an earnest purpose for precision metrology. As a response to this goal, the weak value amplification approach has been developed for measuring ultra-small physical effects, realizing sensitivity that had…
We study the weak-value amplification (WVA) in a phase measurement with an optical interferometer in which shot noise limits the sensitivity. We compute the signal and the shot noise including the full-order interaction terms of the WVA,…
We present the first experimental demonstration of the optical Sagnac effect at the single-photon level. Using a high quality guided-wave heralded single- photon source at 1550 nm and a fibre optics setup, we obtain an interference pattern…
We find a phase matching condition for enhancement of sensitivity in a Mach-Zehnder interferometer illuminated by an arbitrary state in one input port and an odd(even) state in the other port. Under this condition, the Fisher information…
We demonstrate a simple, robust, and ultrabright parametric down-conversion source of polarization-entangled photons based on a polarization Sagnac interferometer. Bidirectional pumping in type-II phase-matched periodically poled KTiOPO4…
Recently, biased weak measurement(BWM) has shown higher precision than both conventional measurement and standard weak measurement(SWM) in optical metrology. In this paper, we propose a scheme of detecting rotation velocity in Sagnac's…
A Sagnac atom interferometer can be constructed using a Bose-Einstein condensate trapped in a cylindrically symmetric harmonic potential. Using the Bragg interaction with a set of laser beams, the atoms can be launched into circular orbits,…
We present a simple and robust design for a squeezing-enhanced Sagnac interferometer that employs the concept of SU(1,1) interference to significantly surpass the classical sensitivity limit (shot-noise limit - SNL) in rotational sensing.…
We study experimentally parametric amplification in the continuous regime using a transverse-degenerate type-II Optical Parametric Oscillator operated below threshold. We demonstrate that this device is able to amplify either in the phase…
We propose and experimentally demonstrate a single-mode fiber length and dispersion measurement system based on a novel frequency-shifted asymmetric Sagnac interferometer incorporating an acousto-optic modulator (AOM). By sweeping the…
Interferometers measure a wide variety of dynamic processes by converting a phase change into an intensity change. Nonlinear interferometers, making use of nonlinear media in lieu of beamsplitters, promise substantial improvement in the…
The extraordinary concept of weak value amplification has attracted considerable attention for addressing foundational questions in quantum mechanics and for metrological applications in high precision measurement of small physical…
Sensitivity of gravitational-wave detectors is limited in the high-frequency band by quantum shot noise and eventually limited by the optical loss in signal recycling cavity. This limit is the main obstacle on the way to detect…
An interferometric arrangement is proposed in which the technique of weak value amplification is implemented in order to enlarge the effect of a single photon on the quadratures of a movable mirror of an optical cavity. The photon interacts…
Weak value amplification is a classical phenomenon that can enhance the sensitivity of a measurement through clever use of interference. The most well-known paradigm of weak value amplification makes use of a Gaussian pulse, which is…
A fully fibered source of entangled photon pairs based on a nonlinear Sagnac interferometer is reported. Operating at telecom wavelengths, the source relies exclusively on standard fiber-optic components and periodically poled lithium…
We propose the difference weak measurement scheme, and illustrate its advantages for measuring small longitude phase-shift in high precision. Compared to the standard interferometry and standard weak measurement schemes, the proposed scheme…
Armstrong et al. have recently presented new ways of combining signals to precisely cancel laser frequency noise in spaceborne interferometric gravitational wave detectors such as LISA. One of these combinations, the symmetrized Sagnac…