Related papers: Continuous phase amplification with a Sagnac inter…
We report results of a high precision phase estimation based on a weak measurements scheme using commercial light-emitting diode. The method is based on a measurement of the imaginary part of the weak value of a polarization operator. The…
We study the amplification of weak magnetic field with Weak-value technique based on Faraday magneto-optic effect. By using a different scheme to perform the Sagnac interferometer with the probe in momentum space, we have demonstrated the…
We use a Sagnac interferometer to measure the dispersive and absorptive properties of room temperature Rubidium vapor on the D_2 line at 780.2 nm. We apply a pump beam such that the resulting Lambda system exhibits Electromagnetically…
The advantages of light and matter-wave Sagnac interferometers -- large area on one hand and high rotational sensitivity per unit area on the other -- can be combined utilizing ultra-slow light in cold atomic gases. While a group-velocity…
We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two…
Weak measurements in combination with post-selection can give rise to a striking amplification effect (related to a large "weak value"). We show that this effect can be understood by viewing the initial state of the pointer as the ground…
The weak measurements based amplification of ultra-small phase was proposed in our previous work. Due to the technical imperfections, the ability of amplification is usually limited in practice. Here we introduce the concept of cascaded…
We reanalyzed our atom interferometer measurement of the electric polarizability of lithium now accounting for the Sagnac effect due to Earth rotation. The resulting correction to the polarizability is very small but the visibility as a…
We theoretically discuss an implementation of a Sagnac interferometer with cold atoms. In contrast to currently existing schemes our protocol does not rely on any free propagation of atoms. Instead it is based on superpositions of fully…
We propose to use weak measurements away from the weak-value amplification regime to carry out precision measurements of time delays of light. Our scheme is robust to several sources of noise that are shown to only limit the relative…
We designed and implemented a novel combination of a Sagnac-interferometer with a Mach-Zehnder interferometer for a source of polarization-entangled photons. The new versatile configuration does not require multi-wavelength polarization…
The Sagnac speed meter interferometer topology can potentially provide enhanced sensitivity to gravitational waves in the audio-band compared to equivalent Michelson interferometers. A challenge with the Sagnac speed meter interferometer…
Weak amplification is a signal enhancement technique which is used to measure tiny changes that otherwise cannot be determined because of technical limitations. It is based on the existence of a special type of interaction which couples a…
We have constructed a counterpropagating optical tweezers setup embedded in a Sagnac interferometer in order to increase the sensitivity of position tracking for particles in the geometrical optics regime. Enhanced position determination…
An experimental proposal is presented in which dark port post-selection together with weak measurements are used to enlarge the radiation pressure effect of a single photon on a mechanical oscillator placed in the middle of a Fabry-Perot…
We describe a matter-wave Sagnac interferometer using Bose condensed atoms confined in a time-orbiting potential trap. Compared to our previous implementation [Moan et al., Phys. Rev. Lett. 124, 120403 (2020)], our new apparatus provides…
Here we introduce interferometric devices by combining optical feedback (cavities) with unbiased multiports, which unlike traditional beam dividers, allow light to reflect back out of the port from which it originated. By replacing the…
Using the profound interferometric philosophy of weak value amplification, we propose a simple, general and a robust polarization method for the amplification and quantification of small magnitudes of all possible polarization anisotropy…
We put forward a new fiber optic sensor for measuring linear velocity with picometer/second sensitivity with Weak-value amplification based on generalized Sagnac effect [Phys. Rev. Lett.\textbf{93}, 143901(2004)].The generalized Sagnac…