The time resolution for several single gap (2 mm) prototype Resistive Plate Chambers (RPC) made of high resistive (bulk resistivity ~ 10^10 - 10^12 ohm cm), 2 mm thick matt finished bakelite paper laminates with silicone coating on the…
A novel design of Resistive Plate Chambers (RPCs), using only a single resistive plate, is being proposed. Based on this design, two large size prototype chambers were constructed and were tested with cosmic rays and in particle beams. The…
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…
The reduction of the average charge per count in the gas along with the capability to discriminate very small signals from noise can allow an efficient and long-term Resistive Plate Chamber detector operation in high radiation background…
Results obtained by the RPC ECOgas@GIF++ Collaboration, using Resistive Plate Chambers operated with new, eco-friendly gas mixtures, based on Tetrafluoropropene and carbon dioxide, are shown and discussed in this paper. Tests aimed to…
The phase-out of Hydrofluorocarbons (HFCs), due to their high Global Warming Potential (GWP), affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluorethane C2H2F4, has created operational difficulties on existing systems…
The Resistive Plate Chambers (RPC) are low-cost charged-particle detectors with good timing resolution and potentially good spatial resolution. Using RPC as gamma detector provides an opportunity for application in positron emission…
There are several working groups that are currently working on high rate RPC's using different materials such as Si-based Ceramics, Low-resistive Glass, low-resistive bakelite etc. A new type of single gap RPC has been fabricated using very…
The reliability of large-area Resistive Plate Chambers (RPCs) operated under High-Luminosity Large Hadron Collider (HL-LHC) conditions is governed by the long-term stability and radiation tolerance of screen-printed graphite/phenoxy…
In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was…
The Muon Chamber (MuCh) is a sub-system of the Compressed Baryonic Matter (CBM) experiment for the detection of low-mass-vector mesons produced in high energy heavy-ion collisions at beam energies ranging from 2 AGeV to 11 AGeV and decaying…
Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of…
The Resistive Plate Chamber (RPC) is widely used in experiments of high energy physics as trigger detector as its good time resolution and high efficiency. In the traditional layout of RPC, the graphite layers are indispensable parts. The…
A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the…
Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…
To achieve high-resolution muography of compact targets in scenarios with complex logistical constraints, we are developing a portable muon detector system utilizing glass Resistive Plate Chambers (RPCs). Although RPCs are well understood…
Optimization of spacer and gas distribution inside glass resistive plate chamber (RPC) is reported. Simulation studies demonstrate improvements on the gas flow velocity homogeneity and lower vorticity inside the gas chamber. The optimized…
The 50 \,kton\, INO-ICAL is a proposed underground high energy physics experiment at Theni, India ($9^{\circ}57'N$, $77^{\circ}16'E$) to study the neutrino oscillation parameters using atmospheric neutrinos. The Resistive Plate Chamber…
A new prototype of large area Multi-gap Resistive Plate Chamber (MRPC) with long readout strips was built. This Long-strip Multi-gap Resistive Plate Chamber (LMRPC) is double stacked and has ten 250 $\mu$m-thick gas gaps. Signals are read…
Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial…