English
Related papers

Related papers: Performances of linseed oil-free bakelite RPC prot…

200 papers

An experimental setup consisting of 12 layers of glass Resistive Plate Chambers (RPCs) of size 2\,m\,$\times$\,2\,m has been built at IICHEP-Madurai (\ang{9;56;14.5}\,N \ang{78;00;47.9}\,E, on the surface) to study the long term performance…

High Energy Astrophysical Phenomena · Physics 2020-12-14 Suryanarayan Mondal , V. M. Datar , Gobinda Majumder , N. K. Mondal , S. Pethuraj , K. C. Ravindran , B. Satyanarayana

This paper reports on the performance of Resistive Plate Chambers (RPCs) as function of the gas flow rate through the chambers and of environmental conditions, such as atmospheric pressure, ambient temperature and air humidity. The chambers…

Instrumentation and Detectors · Physics 2010-05-07 Burak Bilki , John Butler , Ed May , Georgios Mavromanolakis , Edwin Norbeck , Jose Repond , David Underwood , Lei Xia , Qingmin Zhang

The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to…

The ALICE Muon IDentifier is composed of 72 single-gap bakelite Resistive Plate Chambers, which have been operational since 2009 in maxi-avalanche mode (discrimination threshold:7 mV without amplification) with a…

Instrumentation and Detectors · Physics 2024-03-21 Alessandro Ferretti

A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this…

Instrumentation and Detectors · Physics 2022-12-21 Atsushi Oya , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Kensuke Yamamoto

Resistive Plate Chambers (RPC) have shown stable operation at the Large Hadron Collider and satisfactory efficiency for the entire Run 1 (2010-2013) and Run 2 (2015-2018) with C$_{2}$H$_{2}$F$_{4}$-based gas mixtures and the addition of…

The evolution of particle detectors dates back to the discovery of X-rays and radioactivity in 1890s. In detector history, the Resistive Plate Chambers (RPCs) are introduced in early 1980s. An RPC is a gaseous detector made up of two…

Instrumentation and Detectors · Physics 2018-11-20 Manisha , V. Bhatnagar , J. S. Shahi , S. Verma , B. P. Mohanty , A. Kumar

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

A Resistive Plate Chamber using Diamond-Like Carbon electrodes (DLC-RPC) has been developed as a background tagging detector in the MEG$~$II experiment. The DLC-RPC is planned to be installed in a high-intensity and low-momentum muon beam.…

Instrumentation and Detectors · Physics 2025-06-13 Masato Takahashi , Sei Ban , Weiyuan Li , Atsuhiko Ochi , Wataru Ootani , Atsushi Oya , Hiromu Suzuki , Kensuke Yamamoto

The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems…

Instrumentation and Detectors · Physics 2024-03-01 A. Blanco , P. Fonte , L. Lopes , M. Pimenta

Resistive Plate Chambers (RPCs) have traditionally operated with high Global Warming Potential (GWP) gas mixtures, adding to the environmental footprint of large-scale physics experiments. In response, efforts are underway to explore…

Instrumentation and Detectors · Physics 2025-06-23 Aashaq Shah , Thomas Adolphus , Yingchang Zhang , Oleg Brandt

In this R&D, an innovative method for producing thin high-pressure laminate (HPL) electrodes for resistive plate chambers (RPC) for future high-energy experiments is introduced. Instead of using thick phenolic HPL (2-mm thick Bakelite),…

Instrumentation and Detectors · Physics 2025-06-05 Kyong Sei Lee , Giuseppe Iaselli , Youngmin Jo , Minho Kang , Tae Jeong Kim , Dayron Ramos Lopez , Gabriella Pugliese

This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail,…

Instrumentation and Detectors · Physics 2016-08-03 G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , R. Iuppa , B. Liberti , L. Paolozzi , E. Pastori , R. Santonico , M. Toppi

In the last two decades Resistive Plate Chambers were employed in the Cosmic Ray Experiments COVER-PLASTEX and ARGO/YBJ. In both experiments the detectors were housed indoors, likely owing to gas distribution requirements and the need to…

Instrumentation and Detectors · Physics 2016-10-12 L. Lopes , P. Assis , A. Blanco , N. Carolino , M. A. Cerda , R. Conceição , O. Cunha , M. Ferreira , P. Fonte , R. Luz , L. Mendes , A. Pereira , M. Pimenta , R. Sarmento , B. Tomé

Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…

Instrumentation and Detectors · Physics 2015-09-08 M. Affatigato , U. Akgun , B. Bilki , F. Corriveau , B. Freund , N. Johnson , C. Neubueser , Y. Onel , J. Repond , L. Xia

Resistive Plate Chambers (RPCs), used for the Muon Spectrometer of the ALICE experiment at CERN LHC, are currently operated in maxi-avalanche mode with a low threshold value and without amplification in the front-end electronics. RPC…

Instrumentation and Detectors · Physics 2020-01-29 Antonio Bianchi

This paper studies the performance of RPCs working with a new family of environment-friendly operating gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement…

Instrumentation and Detectors · Physics 2022-05-18 G. Proto , B. Liberti , R. Santonico , G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , A. Paoloni , E. Pastori , L. Pizzimento , A. Rocchi

The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. In…

The low cost and high resolution Multi-gap Resistive Plate Chamber (MRPC) opens up a new possibility to find an efficient alternative detector for the Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…

Instrumentation and Detectors · Physics 2015-06-22 A. Banerjee , A. Roy , S. Biswas , S. Chattopadhyay , G. Das , S. Pal