Related papers: Physics of reverse annealing in high-resistivity C…
Here we report the results of an investigation into the effects of ionizing radiation on commercial-off-the-shelf InGaAs and Si photodiodes. The photodiodes were exposed to 30, 52, and 98 MeV protons with fluences ranging from 10^8 -…
We have developed a new method to correct dark current at relatively high temperatures for Charge-Coupled Device (CCD) images when dark frames cannot be obtained on the telescope. For images taken with the Antarctic Survey Telescopes (AST3)…
The scheduled High Luminosity upgrade of the CERN Large Hadron Collider presents new challenges in terms of radiation hardness. As a consequence, campaigns to qualify the radiation hardness of detector sensors and components are undertaken…
The charge transfer inefficiency (CTI) of the X-ray CCDs on board the Suzaku satellite (X-ray Imaging Spectrometers; XIS) has increased since the launch due to radiation damage, and the energy resolution has been degraded. To improve the…
The cooling flow cluster Hydra A was observed during the orbital activation and calibration phase of the Chandra Observatory. While the X-ray image of the cluster exhibits complex structure in the central region as reported in McNamara…
Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a…
Limited radiation hardness is the primary drawback to implementing Silicon Photomultipliers (SiPMs) in high-luminosity environments, such as the Compressed Baryonic Matter (CBM) experiment. Hadron irradiation generates defects in the…
The effect of $\alpha$-particle irradiation on a NdFeAs(O,F) thin film has been investigated to determine how the introduction of defects affects basic superconducting properties, including the critical temperature $T_c$ and the upper…
The X-ray Imaging Spectrometer (XIS) on board the Suzaku satellite is an X-ray CCD camera system that has superior performance such as a low background, high quantum efficiency, and good energy resolution in the 0.2-12 keV band. Because of…
CryoCsI, the proposed prototype, is a cryogenic undoped CsI scintillating detector, which has a much lower energy threshold potentially down to 0.5 keV$_{nr}$ compared to the doped CsI. This enhanced sensitivity of CryoCsI allows for the…
The performance of nine RHESSI germanium detectors has been gradually deteriorating since its launch in 2002 because of radiation damage caused by passing through the Earth's radiation belts. To restore its former sensitivity, the…
The accretion-induced collapse (AIC) of a white dwarf in a binary with a nondegenerate companion can sometimes lead to the formation of a rapidly rotating and highly magnetized neutron star (NS). The spin-down of this NS can drive a…
The Soft X-ray Imager (SXI) is an X-ray CCD camera of the Xtend system onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which was successfully launched on September 7, 2023 (JST). During ground cooling tests of the CCDs in…
CMOS detectors offer many advantages over CCDs for optical and UV astronomical applications, especially in space where high radiation tolerance is required. However, astronomical instruments are most often designed for low light-level…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
Plasma effect is observed in CCDs exposed to heavy ionizing alpha-particles with energies in the range 0.5 - 5.5 MeV. The results obtained for the size of the charge clusters reconstructed on the CCD pixels agrees with previous measurements…
A Lead Tungstate crystal produced for the electromagnetic calorimeter of the CMS experiment at the LHC was cut into three equal-length sections. The central one was irradiated with 290 MeV/c positive pions up to a fluence of (5.67 +-…
Radiation damage tests in hydrogenated amorphous silicon (a-Si:H) flexible flux and dose-measuring devices have been performed with a 3 MeV proton beam, to evaluate combined displacement and total ionizing dose damage. The tested devices…
To face the higher levels of radiation due to the 10-fold increase in integrated luminosity during the High-Luminosity LHC, the CMS detector will replace the current Calorimeter Endcap (CE) using the High-Granularity Calorimeter (HGCAL)…
Silicon photomultipliers (SiPMs) will be used to read out all calorimeters in the ePIC experiment at the Electron-Ion Collider (EIC). A thorough characterization of the radiation damage expected for SiPMs under anticipated EIC fluences is…