Related papers: Thick GEM versus thin GEM in two-phase argon avala…
A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle…
Systematic uncertainties in accelerator oscillation neutrino experiments arise mostly from nuclear models describing neutrino-nucleus interactions. To mitigate these uncertainties, we can study neutrino-nuclei interactions with detectors…
A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour…
A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through…
Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm x 10 cm and a two-dimensional, laser-etched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab.…
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-\eta region. An international collaboration is investigating the possibility of covering the 1.6 < |\eta| < 2.4 region of…
In this work we describe a parallel geometry gaseous detector constituted by a thin (0.6 mm) amplifying gap preceded by a drift region. The gap is delimited by a metal plate and by a wire mesh. The detector can count up to a rate of 10^7…
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25…
A study has been carried out to evaluate the performance stability of Gas Electron Multiplier (GEM) chamber prototypes in the laboratory using $^{55}$Fe radiation source with Argon and CO$_2$ gas mixture. This research focuses on the…
Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future…
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of…
The Gas Electron Multiplier detectors with wire and metallic electrodes, with a gas filling in the gap between them were proposed and tested. The main advantage of these Gas Electron Multipliers compared to standard ones consists in their…
The optimization of resistive anode for two dimensional imaging detectors which consists of a series of high resistive square pads surrounding by low resistive strips has been studied by both numerical simulations and experimental tests. It…
The recently completed Forward GEM Tracker (FGT) of the STAR experiment at RHIC took advantage of commercially produced GEM foils based on double-mask chemical etching techniques. With future experiments proposing detectors that utilize…
The CMS muon system operates gas-based detectors. Upgrades of the detectors and trigger components are needed to cope with increasingly challenging conditions of the HL-LHC. New irradiation tests are performed to ensure that the muon…
The Gas Electron Multiplier (GEM) detectors are widely used in high-energy physics (HEP) experiments as tracking devices because of their excellent position resolution and to handle high particle rates capability. Charging-up effect is a…
Multiple-GEM detectors are considered to be good candidates for tracking devices in experiments with high hadronic background. We present the results of the triple-GEM detectors beam test in a high intensity pion beam. The detectors had an…
In this work we characterized a X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers (GEM). The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the…
Gas electron multipliers (GEMs) have been overcoated with a high resistivity 10e14 - 10e15 Ohms / square amorphous carbon layer. The coating avoids charging up of the holes and provides a constant gain immediately after switching on…