English
Related papers

Related papers: Thick GEM versus thin GEM in two-phase argon avala…

200 papers

A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle…

Instrumentation and Detectors · Physics 2013-02-14 M. Poli Lener , M. Bazzi , G. Corradi , C. Curceanu , A. D'Uffizi , C. Paglia , A. Romero Vidal , E. Sbardella , A. Scordo , D. Tagnani , J. Zmeskal

Systematic uncertainties in accelerator oscillation neutrino experiments arise mostly from nuclear models describing neutrino-nucleus interactions. To mitigate these uncertainties, we can study neutrino-nuclei interactions with detectors…

Instrumentation and Detectors · Physics 2023-10-31 R. M Amarinei , F. Sánchez , E. Roe , S. Bordoni , L. Giannessi , T Lux , E. Radicioni

A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour…

Instrumentation and Detectors · Physics 2018-11-14 B. Aimard , Ch. Alt , J. Asaadi , M. Auger , V. Aushev , D. Autiero , M. M. Badoi , A. Balaceanu , G. Balik , L. Balleyguier , E. Bechetoille , D. Belver , A. M. Blebea-Apostu , S. Bolognesi , S. Bordoni , N. Bourgeois , B. Bourguille , J. Bremer , G. Brown , G. Brunetti , L. Brunetti , D. Caiulo , M. Calin , E. Calvo , M. Campanelli , K. Cankocak , C. Cantini , B. Carlus , B. M. Cautisanu , M. Chalifour , A. Chappuis , N. Charitonidis , A. Chatterjee , A. Chiriacescu , P. Chiu , S. Conforti , P. Cotte , P. Crivelli , C. Cuesta , J. Dawson , I. De Bonis , C. De La Taille , A. Delbart , D. Desforge , S. Di Luise , B. S. Dimitru , F. Doizon , C. Drancourt , D. Duchesneau , F. Dulucq , J. Dumarchez , F. Duval , S. Emery , A. Ereditato , T. Esanu , A. Falcone , K. Fusshoeller , A. Gallego-Ros , V. Galymov , N. Geroy , A. Gendotti , M. Gherghel-Lascu , C. Giganti , I. Gil-Botella , C. Girerd , M. C. Gomoiu , P. Gorodetzky , E. Hamada , R. Hanni , T. Hasegawa , A. Holin , S. Horikawa , M. Ikeno , S. Jimenez , A. Jipa , M. Karolak , Y. Karyotakis , S. Kasai , K. Kasami , T. Kishishita , I. Kreslo , D. Kryn , C. Lastoria , I. Lazanu , G. Lehmann-Miotto , N. Lira , K. Loo , D. Lorca , P. Lutz , T. Lux , J. Maalampi , G. Maire , M. Maki , L. Manenti , R. M. Margineanu , J. Marteau , G. Martin-Chassard , H. Mathez , E. Mazzucato , G. Misitano , B. Mitrica , D. Mladenov , L. Molina Bueno , C. Moreno Martinez , J. P. Mols , T. S. Mosu , W. Mug , A. Munteanu , S. Murphy , K. Nakayoshi , S. Narita , D. Navas-Nicolas , K. Negishi , M. Nessi , M. Niculescu-Oglinzanu , L. Nita , F. Noto , A. Noury , Y. Onishchuk , C. Palomares , M. Parvu , T. Patzak , Y. Penichot , E. Pennacchio , L. Periale , H. Pessard , F. Pietropaolo , Y. Piret , B. Popov , D. Pugnere , B. Radics , D. Redondo , C. Regenfus , A. Remoto , F. Resnati , Y. A. Rigaut , C. Ristea , A. Rubbia , A. Saftoiu , K. Sakashita , F. Sanchez , C. Santos , A. Scarpelli , C. Schloesser , L. Scotto Lavina , K. Sendai , F. Sergiampietri , S. Shahsavarani , M. Shoji , J. Sinclair , J. Soto-Oton , D. L. Stanca , D. Stefan , P. Stroescu , R. Sulej , M. Tanaka , V. Toboaru , A. Tonazzo , W. Tromeur , W. H. Trzaska , T. Uchida , F. Vannucci , G. Vasseur , A. Verdugo , T. Viant , S. Vihonen , S. Vilalte , M. Weber , S. Wu , J. Yu , L. Zambelli , M. Zito

A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through…

Instrumentation and Detectors · Physics 2017-11-22 Luca Moleri , Purba Bhattacharya , Artur E. C. Coimbra , Amos Breskin , Shikma Bressler

Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm x 10 cm and a two-dimensional, laser-etched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab.…

In this work we describe a parallel geometry gaseous detector constituted by a thin (0.6 mm) amplifying gap preceded by a drift region. The gap is delimited by a metal plate and by a wire mesh. The detector can count up to a rate of 10^7…

Instrumentation and Detectors · Physics 2007-05-23 P. Fonte , R. Ferreira-Marques , Y. Ivaniouchenkov , V. Peskov , A. Policarpo

A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25…

A study has been carried out to evaluate the performance stability of Gas Electron Multiplier (GEM) chamber prototypes in the laboratory using $^{55}$Fe radiation source with Argon and CO$_2$ gas mixture. This research focuses on the…

Instrumentation and Detectors · Physics 2026-04-10 S. Mandal , S. Gope , S. Das , S. Biswas

Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future…

Instrumentation and Detectors · Physics 2018-12-12 Aashaq Shah , CMS-Muon Collaboration

Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of…

Instrumentation and Detectors · Physics 2014-12-10 D. Abbaneo , M. Abbas , M. Abbrescia , A. A. Abdelalim , M. Abi Akl , W. Ahmed , W. Ahmed , P. Altieri , R. Aly , C. Asawatangtrakuldee , A. Ashfaq , P. Aspell , Y. Assran , I. Awan , S. Bally , Y. Ban , S. Banerjee , P. Barria , L. Benussi , V. Bhopatkar , S. Bianco , J. Bos , O. Bouhali , S. Braibant , S. Buontempo , C. Calabria , M. Caponero , C. Caputo , F. Cassese , A. Castaneda , S. Cauwenbergh , F. R. Cavallo , A. Celik , M. Choi , K. Choi , S. Choi , J. Christiansen , A. Cimmino , S. Colafranceschi , A. Colaleo , A. Conde Garcia , M. M. Dabrowski , G. De Lentdecker , R. De Oliveira , G. de Robertis , S. Dildick , B. Dorney , W. Elmetenawee , G. Fabrice , M. Ferrini , S. Ferry , P. Giacomelli , J. Gilmore , L. Guiducci , A. Gutierrez , R. M. Hadjiiska , A. Hassan , J. Hauser , K. Hoepfner , M. Hohlmann , H. Hoorani , Y. G. Jeng , T. Kamon , P. E. Karchin , H. S. Kim , S. Krutelyov , A. Kumar , J. Lee , T. Lenzi , L. Litov , F. Loddo , T. Maerschalk , G. Magazzu , M. Maggi , Y. Maghrbi , A. Magnani , N. Majumdar , P. K. Mal , K. Mandal , A. Marchioro , A. Marinov , J. A. Merlin , A. K. Mohanty , A. Mohapatra , S. Muhammad , S. Mukhopadhyay , M. Naimuddin , S. Nuzzo , E. Oliveri , L. M. Pant , P. Paolucci , I. Park , G. Passeggio , B. Pavlov , B. Philipps , M. Phipps , D. Piccolo , H. Postema , G. Pugliese , A. Puig Baranac , A. Radi , R. Radogna , G. Raffone , S. Ramkrishna , A. Ranieri , C. Riccardi , A. Rodrigues , L. Ropelewski , S. RoyChowdhury , M. S. Ryu , G. Ryu , A. Safonov , A. Sakharov , S. Salva , G. Saviano , A. Sharma , S. K. Swain , J. P. Talvitie , C. Tamma , A. Tatarinov , N. Turini , T. Tuuva , J. Twigger , M. Tytgat , I. Vai , M. van Stenis , R. Venditi , E. Verhagen , P. Verwilligen , P. Vitulo , D. Wang , M. Wang , U. Yang , Y. Yang , R. Yonamine , N. Zaganidis , F. Zenoni , A. Zhang

The Gas Electron Multiplier detectors with wire and metallic electrodes, with a gas filling in the gap between them were proposed and tested. The main advantage of these Gas Electron Multipliers compared to standard ones consists in their…

Instrumentation and Detectors · Physics 2010-12-22 B. M. Ovchinnikov , V. V. Parusov , Yu. B. Ovchinnikov

The optimization of resistive anode for two dimensional imaging detectors which consists of a series of high resistive square pads surrounding by low resistive strips has been studied by both numerical simulations and experimental tests. It…

Instrumentation and Detectors · Physics 2016-09-06 Xu-Dong Ju , Ming-Yi Dong , Yi-Chen Zhao , Chuan-Xing Zhou , Qun Ouyang

The recently completed Forward GEM Tracker (FGT) of the STAR experiment at RHIC took advantage of commercially produced GEM foils based on double-mask chemical etching techniques. With future experiments proposing detectors that utilize…

Instrumentation and Detectors · Physics 2014-11-27 M. Posik , B. Surrow

The CMS muon system operates gas-based detectors. Upgrades of the detectors and trigger components are needed to cope with increasingly challenging conditions of the HL-LHC. New irradiation tests are performed to ensure that the muon…

Instrumentation and Detectors · Physics 2018-09-07 Jian Wang

The Gas Electron Multiplier (GEM) detectors are widely used in high-energy physics (HEP) experiments as tracking devices because of their excellent position resolution and to handle high particle rates capability. Charging-up effect is a…

Instrumentation and Detectors · Physics 2026-05-06 S. Mandal , S. Ghosh , S. Das , S. Biswas

Multiple-GEM detectors are considered to be good candidates for tracking devices in experiments with high hadronic background. We present the results of the triple-GEM detectors beam test in a high intensity pion beam. The detectors had an…

Instrumentation and Detectors · Physics 2007-05-23 A. Bondar , A. Buzulutskov , L. Shekhtman , A. Sokolov , A. Vasiljev

In this work we characterized a X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers (GEM). The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting…

Instrumentation and Detectors · Physics 2019-08-01 Geovane G. A. de Souza , Hugo Natal da Luz

The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the…

Instrumentation and Detectors · Physics 2012-08-31 Serge Duarte Pinto , Philippe Carrière , Jens Spanggaard , Gerard Tranquille

Gas electron multipliers (GEMs) have been overcoated with a high resistivity 10e14 - 10e15 Ohms / square amorphous carbon layer. The coating avoids charging up of the holes and provides a constant gain immediately after switching on…

Instrumentation and Detectors · Physics 2008-11-26 S. Beirle , U. Werthenbach , G. Zech , T. Zeuner
‹ Prev 1 8 9 10 Next ›