English
Related papers

Related papers: Propagation-based x-ray phase-contrast imaging wit…

200 papers

A device based on a three-block Fresnel zone plate interferometer is proposed for hard X-ray phase-contrast imaging. The device combines a low requirement for the coherence of the initial radiation (the interferometer operates in the…

Instrumentation and Detectors · Physics 2021-04-22 L. A. Haroutunyan

In this study, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based (PB) x-ray phase contrast imaging. Based on single Gaussian peak fits to the x-ray…

Instrumentation and Detectors · Physics 2018-08-15 A. H. Lumpkin , A. B. Garson , M. A. Anastasio

When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. In- terference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made…

Quantitative phase imaging has become a topic of considerable interest in the microscopy community. We have recently described one such technique based on the use of a partitioned detection aperture, which can be operated in a single shot…

Optics · Physics 2015-10-20 Roman Barankov , Jean-Charles Baritaux , Jerome Mertz

Using higher-order coherence of thermal light sources, the resolution power of standard x-ray imaging techniques can be enhanced. In this work, we applied the higher-order measurement to far-field x-ray diffraction and near-field phase…

X-ray diffraction was demonstrated from shock-compressed polycrystalline metal on nanosecond time scales. Laser ablation was used to induce shock waves in polycrystalline foils of Be, 25 to 125 microns thick. A second laser pulse was used…

Other Condensed Matter · Physics 2008-01-23 Damian C. Swift

Phase Contrast Imaging (PCI), Dark-Field (DF) and Directional Dark-Field (DDF) imaging are recent X-ray imaging modalities that have demonstrated their interest by providing access to information and contrasts different from those provided…

Image and Video Processing · Electrical Eng. & Systems 2023-04-25 Clara Magnin , Laurene Quenot , Sylvain Bohic , Dan Mihai Cenda , Manuel Fernández Martínez , Blandine Lantz , Bertrand Faure , Emmanuel Brun

X-rays are commonly used in imaging experiments due to their penetration power, which enables non-destructive resolution of internal structures in samples that are opaque to visible light. Time-resolved X-ray tomography is the…

Propagation-based phase-contrast X-ray imaging is a promising technique for in~vivo medical imaging, offering lower radiation doses than traditional attenuation-based imaging. Previous studies have focused on X-ray energies below 50 keV for…

X-Ray Phase-Contrast Imaging (PCI) yields absorption, differential phase, and dark-field images. Computed Tomography (CT) of grating-based PCI can in principle provide high-resolution soft-tissue contrast. Recently, grating-based PCI took…

Ptychography is an attractive advance of coherent diffraction imaging (CDI), which can provide high lateral resolution and wide field of view. The theoretical resolution of ptychography is dose-limited, therefore making ptychography…

Biological Physics · Physics 2025-01-09 Huixiang Lin , Fucai Zhang

Biological soft tissues encountered in clinical and pre-clinical imaging mainly consist of light element atoms, and their composition is nearly uniform with little density variation. Thus, x-ray attenuation imaging suffers from low image…

Medical Physics · Physics 2011-06-28 Wenxiang Cong , Atsushi Momose , Ge Wang

We present a multi-aperture analyser set-up for performing X-ray phase contrast imaging in planar and three-dimensional modalities. A multi-slice representation of the sample is used to establish a quantitative relation between projection…

Instrumentation and Detectors · Physics 2017-06-21 M. Endrizzi , F. A. Vittoria , L. Rigon , D. Dreossi , A. Olivo

A new method is developed for three-dimensional (3D) reconstruction of multi-material objects using propagation-based X-ray phase-contrast tomography (PB-CT) with phase retrieval via the contrast transfer function (CTF) formalism. The…

Medical Physics · Physics 2023-05-15 Darren A. Thompson , Yakov I. Nesterets , Konstantin M. Pavlov , Timur E. Gureyev

Phase contrast X-ray imaging (PCXI) is an emerging imaging modality that has the potential to greatly improve radiography for medical imaging and materials analysis. PCXI makes it possible to visualise soft-tissue structures that are…

Medical differential phase contrast x-ray imaging (DPCI) promises improved soft-tissue contrast at lower x-ray dose. The dose strongly depends on both the angular sensitivity and on the visibility of a grating-based Talbot-Lau…

Medical Physics · Physics 2016-03-23 Oliver Preusche

Ptychography enables coherent diffractive imaging (CDI) of extended samples by raster scanning across the illuminating XUV/X-ray beam thereby generalizing the unique advantages of CDI techniques. Table-top realizations of this method are…

In conventional x-ray ptychography, diffraction data is collected by scanning a sample through a monochromatic, and spatially coherent, x-ray beam. A high-resolution image is then retrieved using an iterative algorithm. Combined with a scan…

Optics · Physics 2025-08-26 Wiebe Stolp , Silvia Cipiccia , Darren Batey , Matthieu Boone

An idea of producing a focused parametric X-ray radiation (PXR) is presented. The PXR is emitted by relativistic charged particles channeling along a bent crystal. Then the PXR emitted from the whole length of the bent crystal is going to…

Accelerator Physics · Physics 2015-06-26 A. V. Shchagin

Recently, the dual-phase grating based X-ray differential phase contrast imaging technique has shown better radiation dose efficiency performance than the Talbot-Lau system. In this paper, we provide a theoretical analyses framework derived…