Related papers: High Resolution Cavity BPM for ILC Final Focal Sys…
A collaboration between Fermilab and the Institute for High Energy Physics (IHEP), Beijing, has developed a beam position monitor for the IHEP test beam facility. This telescope is based on 5 stations of silicon strip detectors having a…
The calibration of the ICARUS photo-detection system is based on a low power laser diode at 405 nm. Laser pulses arrive to one optical switch and then are sent to 36 UHV flanges, by 20 meters long optical patches. Light is then delivered to…
A new Higher Order Mode (HOM) damper was designed and tested for the Booster accelerator cavity at Fermilab. In anticipation of the PIP-II upgrade, it was discovered that the higher beam intensity of PIP-II may cause beam instability due to…
Synchrotron radiation with the characteristic of high brilliance, high level of polarization, high collimation, low emittance and wide tunability in energy has been used as a standard source in metrology(1, 2). For a decade, lots of…
All observations by the aperture photometer (PHT-P) and the far-infrared (FIR) camera section (PHT-C) of ISOPHOT included reference measurements against stable internal fine calibration sources (FCS) to correct for temporal drifts in…
This paper presents a robust 6-DOF relative navigation by combining the iterative closet point (ICP) registration algorithm and a noise-adaptive Kalman filter (AKF) in a closed-loop configuration together with measurements from a laser…
In this article, we present a deflection measurement setup for Atomic Force Microscopy (AFM). It is based on a quadrature phase differential interferometer: we measure the optical path difference between a laser beam reflecting above the…
Interpixel capacitance (IPC) is a deterministic electronic coupling that results in a portion of the collected signal incident on one pixel of a hybridized detector array being measured in adjacent pixels. Data collected by light sensitive…
A logarithm processing algorithm to measure beam transverse size and position is proposed and preliminary experimental results in Hefei Light Source II (HLS II) are given. The algorithm is based on only 4 successive channels of 16 anode…
This paper presents the design and characterization of a monolithic integrated circuit (IC) including digital silicon photomultipliers (dSiPMs) arranged in a 32$~\times~$32 pixel matrix at 70$~\mu$m pitch. The IC provides per-quadrant time…
The National Ignition Facility (NIF) requires that pulses from each of the 192 laser beams be positioned on target with an accuracy of 50 um rms. Beam quality must be sufficient to focus a total of 1.8 MJ of 0.351-um light into a…
One of the possible ways to maintain the micrometer spatial resolution while performing ion beam analysis in the air is to increase the energy of ions. In order to explore capabilities and limitations of this approach, we have tested a…
We present a study of high-$\beta$* optics configurations at Interaction Point 2 (IP2) of the Large Hadron Collider (LHC), developed to enable forward and diffractive physics measurements with the ALICE experiment during Runs 3 and 4. Using…
For the High-Luminosity (HL-LHC) phase, the upgrade of the Compact Muon Solenoid (CMS) experiment at CERN will include a novel MIP Timing Detector (MTD). The central part of MTD, the barrel timing layer (BTL), is designed to provide a…
Particle therapy is a well established clinical treatment of tumors. More than one hundred particle therapy centers are in operation world wide. The advantage of using hadrons like protons or carbon ions as particles for tumor irradiation…
Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated…
A compact resonance ionization mass spectrometer is developed using two laser diodes and a quadrupole mass spectrometer to perform trace element analysis of potassium. With the help of a narrow linewidth of the laser diode, the isotope…
A single channel, high precision ionization chamber has been built for monitoring the relative intensity of X-rays in the energy range above 5 keV. It can be used in experiments, such as EXAFS, where simultaneous high precision monitoring…
Ions with similar charge-to-mass ratios cannot be separated from existing beam profile monitors (BPMs) in nuclear facilities in which low-energy radioactive ions are produced due to nuclear fusion reactions. In this study, we developed a…
Bit-interleaved coded modulation (BICM) is a practical approach for reliable communication over the AWGN channel in the bandwidth limited regime. For a signal point constellation with 2^m points, BICM labels the signal points with bit…