Related papers: Development of Tracking Detectors with industriall…
Study of the uniformity of gain, energy resolution and count rate over active area of a triple GEM detector has been performed using a strong Fe55 X-ray source with premixed gas of Argon and CO2 in 70/30 ratio and conventional NIM…
The upgrade of the CMS detector for the high luminosity LHC (HL-LHC) will include gas electron multiplier (GEM) detectors in the end-cap muon spectrometer. Due to the limited supply of large area GEM detectors, the Korean CMS (KCMS)…
Gas Electron Multiplier (GEM) is a cutting edge Micro Pattern Gaseous detector (MPGD) technology suitable as tracking device in high rate Heavy-Ion (HI) experiments for their good spatial resolution and most importantly high rate handling…
A cylindrical GEM detector is under development, to serve as an upgraded inner tracker at the BESIII spectrometer. It will consist of three layers of cylindrically-shaped triple GEMs surrounding the interaction point. The experiment is…
Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the…
For its ease manufacturing, flexible geometry, and cheap manufacturing cost, the gas electron multiplier (GEM) detector can be used as an x-ray image sensor. For this purpose, we acquired relative detection efficiencies and suggested a…
A study has been carried out to evaluate the performance stability of Gas Electron Multiplier (GEM) chamber prototypes in the laboratory using $^{55}$Fe radiation source with Argon and CO$_2$ gas mixture. This research focuses on the…
Gas Electron Multiplier (GEM) detector, one of the advanced members of the Micro Pattern Gas Detector (MPGD) group, is widely used in High Energy Physics (HEP) experiments. The high rate handling capability and spatial resolution make it a…
A GEM detector with an effective area of 30*30 cm2 has been constructed using an improved self-stretch technique, which enables an easy and fast GEM assembling. The design and assembling of the detector is described. Results from tests of…
The ALICE (A Large Ion Collider Experiment) experiment at the Large Hadron Collider (LHC) at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC) of ALICE is a…
We describe a concept for a NASA SMEX Mission in which Gas Electron Multiplier (GEM) detectors, developed at CERN, are adapted for use in X-ray astronomy. These detectors can be used to obtain moderately large detector area and…
Triple-GEM detectors for the GE2/1 and ME0 stations of the endcap muon system for the Phase-2 upgrade of the CMS Experiment have been operated in a test beam to measure their efficiency and spatial resolution, together with a high spatial…
A Time Projection Chamber (TPC) using micro-pattern gas detectors is planned as the main tracking device for a detector at the next Linear Collider. A novel support structure for Gas Electron Multipliers (GEMs), which minimizes the material…
The Gas Electron Multiplier (GEM) detector is one of the advanced members of the Micro Pattern Gas Detector (MPGD) family, used in High Energy Physics (HEP) experiments as a tracking device due to its high rate handling capability and good…
The increasing demand for Gas Electron Multiplier (GEM) foils has been driven by their application in many current and proposed high-energy physics experiments. Micropack, a Bengaluru-based company, has established and commercialized GEM…
In this work we characterized a X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers (GEM). The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting…
We report promising initial results obtained with new resistive-electrode GEM (RETGEM) detectors manufactured, for the first time, using screen printing technology. These new detectors allow one to reach gas gains nearly as high as with…
A quadruple GEM detector has been assembled in a standalone configuration and operated using Ar and CO$_2$ gas mixtures in proportions of 70:30 and 90:10. Detailed performance study of the detector has been made by using $^{106}$Ru-Rh…
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| \eta |<2.4$ endcap region. With a sufficiently fine…
We have developed a new design of a GEM-like detector with single-layer electrodes made of a resistive kapton. This detector can operate at gains close to 10E5 even in pure Ar and Ne and if transited to discharges at higher gains they, due…