English

Determining Curie temperature of (Ga,Mn)As samples based on electrical transport measurements: low Curie temperature case

Materials Science 2016-06-17 v1

Abstract

In this paper we show that the widely accepted method of the determination of Curie temperature (TC) in (Ga,Mn)As samples, based on the position of the peak in the temperature derivative of the resistivity,completely fails in the case of non-metallic and low-TC unannealed samples. In this case we propose an alternative method, also based on electric transport measurements, which exploits temperature dependence of the second derivative of the resistivity upon magnetic field.

Keywords

Cite

@article{arxiv.1606.05132,
  title  = {Determining Curie temperature of (Ga,Mn)As samples based on electrical transport measurements: low Curie temperature case},
  author = {Adam Kwiatkowski and Marta Gryglas-Borysiewicz and Piotr Juszynski and Jacek Przybytek and Maciej Sawicki and Janusz Sadowski and Dariusz Wasik and Michal Baj},
  journal= {arXiv preprint arXiv:1606.05132},
  year   = {2016}
}

Comments

5 pages, 3 figures