Abstract

The performance of a particle detector derived from nitride read-only memory (NROM) technology is evaluated, with immediate applications in space-based heavy ion radiation monitoring and detection. Irradiation exposures are performed using 40 MeV/u 78^{78}Kr and 10 MeV/u 4^4He particle beams at the Texas A&M University Cyclotron Institute. The results show a strong sensitivity to high-Z heavy ions, and medium sensitivity to low-Z heavy ions.