English

Vapor-cell-based atomic electrometry for detection frequencies below kHz

Atomic Physics 2020-05-20 v2 Quantum Physics

Abstract

Rydberg-assisted atomic electrometry using alkali-metal atoms contained inside a vacuum environment for detecting external electric fields (E-fields) at frequencies << a few kHz has been quite challenging due to the low-frequency E-field screening effect that is caused by the alkali-metal atoms adsorbed on the inner surface of the container. We report a very slow E-field screening phenomenon with a time scale up to \sim second on a rubidium (Rb) vapor cell that is made of monocrystalline sapphire. Using this sapphire-made Rb vapor cell with optically induced, internal bias E-field, we demonstrate vapor-cell-based, low-frequency atomic electrometry that responds to the E-field strength linearly. Limited by the given experimental conditions, this demonstrated atomic electrometer uses an active volume of 11 mm3^3 and delivers a spectral noise floor around 0.340.34 (mV/m)/Hz\sqrt{\rm Hz} and the 3-dB low cut-off frequency around 770 Hz inside the vapor cell. This work investigates a regime of vapor-cell-based atomic electrometry that was seldom studied before, which may enable more applications that utilize atomic E-field sensing technology.

Keywords

Cite

@article{arxiv.2002.04145,
  title  = {Vapor-cell-based atomic electrometry for detection frequencies below kHz},
  author = {Yuan-Yu Jau and Tony Carter},
  journal= {arXiv preprint arXiv:2002.04145},
  year   = {2020}
}

Comments

10 pages, 8 figures

R2 v1 2026-06-23T13:37:40.801Z