English

Data Acquisition System for the CALICE AHCAL Calorimeter

Instrumentation and Detectors 2019-08-13 v3 High Energy Physics - Experiment

Abstract

The data acquisition system (DAQ) for a highly granular analogue hadron calorimeter (AHCAL) for the future International Linear Collider is presented. The developed DAQ chain has several stages of aggregation and scales up to 8 million channels foreseen for the AHCAL detector design. The largest aggregation device, Link Data Aggregator, has 96 HDMI connectors, four Kintex7 FPGAs and a central Zynq System-On-Chip. Architecture and performance results are shown in detail. Experience from DESY testbeams with a small detector prototype consisting of 15 detector layers are shown.

Keywords

Cite

@article{arxiv.1701.02232,
  title  = {Data Acquisition System for the CALICE AHCAL Calorimeter},
  author = {Jiri Kvasnicka},
  journal= {arXiv preprint arXiv:1701.02232},
  year   = {2019}
}

Comments

9 pages, proceedings of TWEPP 2016 - Topical Workshop on Electronics for Particle Physics

R2 v1 2026-06-22T17:44:55.603Z