Related papers: Improved Precision Measurement of the Casimir Forc…
We report an improved precision measurement of the Casimir force using metallic gold surfaces. The force is measured between a large gold coated sphere and flat plate using an Atomic Force Microscope. The use of gold surfaces removes some…
We have used an atomic force microscope to make precision measurements of the Casimir force between a metallized sphere of diameter 196 microns and flat plate. The force was measured for plate-sphere separations from 0.1 to 0.9 microns. The…
The measurement of the Casimir force between a large gold coated sphere and single crystal silicon plate is performed with an atomic force microscope. A rigorous statistical comparison of data with theory is done, without use of the concept…
An upper limit on the Casimir force is found using the dielectric functions of perfect crystalline materials which depend only on well defined material constants. The force measured with the atomic force microscope is larger than this limit…
We consider detailed roughness and conductivity corrections to the Casimir force in the recent Casimir force measurement employing an Atomic Force Microscope. The roughness of the test bodies-a metal plate and a sphere- was investigated…
Experimental methods and procedures required for precision measurements of the Casimir force are presented. In particular, the best practices for obtaining stable cantilevers, calibration of the cantilever, correction of thermal and…
We compare theory and experiment in the Casimir force measurement between gold surfaces performed with the atomic force microscope. Both random and systematic experimental errors are found leading to a total absolute error equal to 8.5 pN…
We report on measurements of the Casimir force in a sphere-plane geometry using a cryogenic force microscope to move the force probe in situ over different materials. We show how the electrostatic environment of the interacting surfaces…
In the current work we present the complete results for the measurement of normal Casimir force between shallow and smooth sinusoidally corrugated gold coated sphere and a plate at various angles between the corrugations using an atomic…
We present a Casimir force setup based on an all-optical ferrule-top sensor. We demonstrate that the instrument can be used to measure the gradient of the Casimir force between a gold coated sphere and a gold coated plate with results that…
We compare theoretical expectations for the Casimir force with the results of precise measurements. The force is calculated at finite temperature for multilayered covering of the bodies using the Lifshitz theory. We argue that the…
The experimental investigation of the Casimir force between a large metallized sphere and semiconductor plate is performed using an atomic force microscope. Improved calibration and measurement procedures permitted reduction in the role of…
We present results on the determination of the differential Casimir force between an Au-coated sapphire sphere and the top and bottom of Au-coated deep silicon trenches performed by means of the micromechanical torsional oscillator in the…
The first precise measurement of the Casimir force between dissimilar metals is reported. The attractive force, between a Cu layer evaporated on a microelectromechanical torsional oscillator, and an Au layer deposited on an Al$_2$O$_3$…
We report measurements of the Casimir force between a gold sphere and a silicon surface with an array of nanoscale, rectangular corrugations using a micromechanical torsional oscillator. At distance between 150 nm and 500 nm, the measured…
We report an improved dynamic determination of the Casimir pressure between two plane plates obtained using a micromachined torsional oscillator. The main improvements in the current experiment are a significant suppression of the surface…
We performed measurements of the gradient of the Casimir force between Au-coated surfaces of a sphere and a plate by means of significantly upgraded dynamic atomic force microscope (AFM) based technique. By introducing combined cleaning…
We report new constraints on extra-dimensional models and other physics beyond the Standard Model based on measurements of the Casimir force between two dissimilar metals for separations in the range 0.2--1.2 $\mu$m. The Casimir force…
The lateral Casimir force between a sinusoidally corrugated gold coated plate and large sphere was measured for surface separations between 0.2 $\mu$m to 0.3 $\mu$m using an atomic force microscope. The measured force shows the required…
We report on the measurement of the Casimir force between conducting surfaces in a parallel configuration. The force is exerted between a silicon cantilever coated with chromium and a similar rigid surface and is detected looking at the…