Related papers: A Fiber Detector Radiation Hardness Test
The coherent dark resonance between the hyperfine levels F=1, m=0 and F=2, m=0 of the rubidium ground state has been observed experimentally with the light of a pulsed mode-locked diode laser operating at the D1 transition frequency. The…
Nuclear radiation detectors play a key role in applications spanning nuclear and particle physics, nuclear engineering, security, and medicine. With the expanded global interest in nuclear power, discreet, inconspicuous, and readily…
A novel composite, scintillating material intended for neutron detection and composed of small (1.5 mm) cubes of KG2-type lithium glass embedded in a matrix of scintillating plastic has been developed in the form of a 2.2 in.-diameter, 3.1…
The P326 experiment at the CERN SPS has been proposed with the purpose of measuring the branching ratio for the decay K^+ \to \pi^+ \nu \bar{\nu} to within 10%. The photon veto system must provide a rejection factor of 10^8 for \pi^0…
The results of the study of the multiwire porous dielectric detector and microstrip porous dielectric detector filled with porous CsI are presented. Detectors were exposed to $\alpha $-particles with energy of 5.46 MeV and X-rays with…
High-finesse microcavities offer a platform for compact, high-precision sensing by employing high-reflectivity, low-loss mirrors to create effective optical path lengths that are orders of magnitude larger than the device geometry. Here, we…
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT)…
Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$…
A micro-pulse lidar at eye-safe wavelength is constructed based on an up-conversion single-photon detector. The ultralow noise detector enables using integration technique to improve the signal-to-noise ratio of the atmospheric…
We experimentally demonstrate optical detection at 12.5~bits per incident photon, 9.4~dB higher than the theoretical limit of conventional coherent detection. A single laser transmits both data and optical clock, undergoes 77~dB of…
The application of reach-through avalanche photodiodes (R'APD) as a photodetector for scintillator tiles has been investigated. The light collected by WLS fibers (0.84mm and 1mm diameter) embedded in the scintillator has been transmited to…
Scintillating fibre detectors combine sub-mm resolution particle tracking, precise measurements of the particle stopping power and sub-ns time resolution. Typically, fibres are read out with silicon photomultipliers (SiPM). Hence, if fibres…
A series of beam tests were conducted at the KEK AR test beamline in ordet to investigate the performance of a prototype detector for instrumentation in the low-E beamline at the CERN H2 line. For the silicon strip detector, the…
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of…
The NeuLAND (New Large-Area Neutron Detector) plastic-scintillator-based time-of-flight detector for 0.1-1.6 GeV neutrons is currently under construction at the Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. In its…
The quadrant silicon detector, a kind of passivated implanted planar silicon detector with quadrant structure on the junction side, gained its wide application in charged particle detection. In this paper, the manufacturing procedure,…
We experimentally demonstrate the realization of a half-polarization-maintaining (half-PM) fiber laser, in which mode-locking is provided by a reflective multimode-interference saturable absorber (SA). In the specially designed SA, linearly…
The performance of 16 and 64 channel photomultipliers coupled to scintillating fibres has been tested. The devices are sensitive to single photoelectrons, show little gain losses for magnetic fields up to 100 Gauss and have moderate optical…
RF frequency transfer over an urban 86 km fibre has been demonstrated with a resolution of 2.10-18 at one day measuring time using an optical compensator. This result is obtained with a reference carrier frequency of 1 GHz, and a rapid…
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument…