English
Related papers

Related papers: The Micro Slit Gas Detector

200 papers

Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number…

Instrumentation and Detectors · Physics 2011-07-19 M. S. Dixit , J. Dubeau , J. -P. Martin , K. Sachs

A prototype of Multi-Wire Proportional Chambers (MWPC) has been fabricated for the study of its various characteristics. The detector contains gold-coated tungsten wires (20 $\mu m$ diameter) on the anode frame, with a pitch of 2.8 mm. The…

Instrumentation and Detectors · Physics 2021-10-06 Rajendra Nath Patra , R. N. Singaraju , S. Biswas , T. K. Nayak , Y. P. Viyogi

In this paper, the design and the performance of a prototype detector based on MicroMegas technology with two detection planes in a common gas volume is discussed. The detector is suited for the forward region of LHC detectors, addressing…

Instrumentation and Detectors · Physics 2017-06-28 Bernard Brickwedde , Andreas Düdder , Matthias Schott , Eda Yildirim

A quality assurance and performance qualification laboratory was built at McGill University for the Canadian-made small-strip Thin Gap Chamber (sTGC) muon detectors produced for the 2019-2020 ATLAS experiment muon spectrometer upgrade. The…

Spectroscopic gas sensing is both a commercial success and a rapidly advancing scientific field. Throughout the years, massive efforts have been directed towards improving detection limits by achieving long interaction pathlengths.…

Plastic gas pipes are widely used in experimental setups for gaseous detectors, due to their flexibility and easiness of use. This report describes the characterization studies realized on the use of plastic gas pipes, particularly in…

Instrumentation and Detectors · Physics 2022-02-25 Roberto Guida , Beatrice Mandelli , Mara Corbetta , Tomoo Mari

The construction of large-scale liquid scintillator detectors is complicated by the need to separate the scintillation region from photomultiplier tubes (PMTs) due to their intrinsic radioactivity. This is generally done using acrylic or…

Instrumentation and Detectors · Physics 2022-04-20 Iwan Morton-Blake , Steven D. Biller

We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33 +/- 0.03,…

Instrumentation and Detectors · Physics 2015-06-26 J. K. Black , P. Deines-Jones , S. E. Ready , R. A. Street

The Low-Gain Avalanche Diode (LGAD) is a new silicon detector and holds wide application prospects in particle physics experiments due to its excellent timing resolution. The LGAD with a pixel size of 1.3 mm $\times$ 1.3 mm was used to…

Instrumentation and Detectors · Physics 2024-05-03 Weiyi Sun , Mengzhao Li , Tianyuan Zhang , Mei Zhao , Yunyun Fan , Shuqi Li , Yuan Feng , Xinhui Huang , Xuan Yang , Wei Wang , Zhijun Liang , Yuekun Heng

Optical gas detection in microsystems is limited by the short micron scale optical path length available. Recently, the concept of slow-light enhanced absorption has been proposed as a route to compensate for the short path length in…

Optics · Physics 2008-09-24 K. H. Jensen , M. N. Alam , B. Scherer , A. Lambrecht , N. A. Mortensen

The Micro-Pattern Gaseous Detectors offer excellent spatial and temporal resolution in harsh radiation environments of high-luminosity colliders. In this work, an attempt has been made to establish an algorithm for estimating the time…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sudeb Bhattacharya

A silicon microstrip detector (SSD) has been developed to have state of the art spatial resolution and a large sensitive area under stringent power constraints. The design incorporates three floating strips with their bias resistors…

We present a concept for an Advanced Compton Telescope (ACT) based on the use of pixelized gas micro-well detectors to form a three-dimensional electron track imager. A micro-well detector consists of an array of individual micro-patterned…

Astrophysics · Physics 2009-11-10 P. F. Bloser , S. D. Hunter , J. M. Ryan , M. L. McConnell , R. S. Miller , T. N. Jackson , B. Bai , S. Jung

We report on the construction and initial performance studies of two micromegas detector quadruplets with an area of 0.5 m$^2$. They serve as prototypes for the planned upgrade project of the ATLAS muon system. Their design is based on the…

The physical processes of charge collection and gas multiplication of a Micro Pixel Chamber (mu-PIC) were studied in detail using a three-dimensional simulation. The collection efficiencies of primary electrons and gas multiplication…

Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged…

Hydrogenated amorphous silicon (a-Si:H) has remarkable radiation resistance properties and can be deposited on a lot of different substrates. A-Si:H based particle detectors have been built since mid 1980s as planar p-i-n or Schottky diode…

The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~\mu\mathrm{m}$ and mesh hole pitch of $63,~78 ~\mu\mathrm{m}$…

Instrumentation and Detectors · Physics 2016-05-12 Purba Bhattacharya , Sudeb Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar , Paul Colas , David Attie

A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $\mu$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas…

A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…

Instrumentation and Detectors · Physics 2016-08-30 Dezső Varga , Gábor Nyitrai , Gergő Hamar , László Oláh