English
Related papers

Related papers: An effective method to read out large scintillator…

200 papers

Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per…

Instrumentation and Detectors · Physics 2015-10-13 Dmitri Denisov , Valery Evdokimov , Strahinja Lukić

We present and discuss the development and performance of a compact scintillating fiber (SciFi) detector for timing to be used in the Mu3e experiment at very high particle rates. The SciFi detector is read out with multichannel silicon…

Instrumentation and Detectors · Physics 2022-08-23 A. Bravar , A. Buonaura , S. Corrodi , A. Damyanova , Y. Demets , L. Gerritzen , Ch. Grab , C. Martin Perez , A. Papa

One contribution to the time resolution of a scintillation detector is the signal time spread due to path length variations of the detected photons from a point source. In an experimental study a rectangular scintillator was excited by…

In this paper we discuss a general approach to use SiPMs in different electrical configurations in combination with numerous scintillator materials for applications in nuclear instrumentation, such as calorimetry and timing. The "hybrid"…

Instrumentation and Detectors · Physics 2018-11-08 Lukas Nies , Hans-Georg Zaunick , Kai-Thomas Brinkmann

We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator…

Muon tomography (MT), based on atmospheric cosmic rays, is a promising technique suitable for nondestructive imaging of the internal structures of mountains. This method uses the measured flux distribution after attenuation, combined with…

Instrumentation and Detectors · Physics 2022-12-27 Bin Zhang , Zhe Wang , Shaomin Chen

Plastic scintillator detectors are used in high energy physics as well as for diagnostic imaging in medicine, beam monitoring on hadron therapy, muon tomography, dosimetry and many security applications. To combine particle tracking and…

A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…

Instrumentation and Detectors · Physics 2008-11-26 Henning Gast , Thomas Kirn , Gregorio Roper Yearwood , Stefan Schael

A muon telescope equipped with four Resistive Plate Chambers of 2 m$^{2}$ per plane was tested with the muon scattering tomography technique. The telescope was operated during several hours with high atomic number materials located at its…

Instrumentation and Detectors · Physics 2022-11-22 João Saraiva , Carlos Alemparte , Daniel Belver , Alberto Blanco , Juan Callón , Jose Collazo , Alfredo Iglesias , Luís Lopes

Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$…

Prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon…

Instrumentation and Detectors · Physics 2016-04-15 Dmitri Denisov , Valery Evdokimov , Strahinja Lukić

In the case of underground experiments for neutrino physics or rare event searches, the background caused by cosmic muons contributes significantly and therefore must be identified and rejected. We proposed and optimized a new detector…

Instrumentation and Detectors · Physics 2017-04-05 Y. P. Zhang , J. L. Xu , H. Q. Lu , P. Zhang , C. C. Zhang , C. G. Yang

We present light yield and uniformity measurements of square and hexagonal tiles read out with silicon photomultipliers via a Y11 wavelength-shifting fiber or directly from the side or from the center at the top face. All tiles are 3~mm…

Instrumentation and Detectors · Physics 2020-08-26 Gerald Eigen , Graham R. Lee

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This work presents a fabrication method based on additive…

Instrumentation and Detectors · Physics 2026-04-28 Chandler Moore , Juan Manfredi , Michael Febbraro , Daniel Rutstrom , Andrew Decker , Ryan Kemnitz , Thomas Ruland , Paul Hausladen

Prototype scintilator+WLS strips with SiPM readout for large muon detection systems were tested in the muon beam of the Fermilab Test Beam Facility. Light yield of up to 137 photoelectrons per muon per strip has been observed, as well as…

Instrumentation and Detectors · Physics 2017-01-03 Dmitri Denisov , Valery Evdokimov , Strahinja Lukić , Predrag Ujić

The light yield and the time resolution of different types of 3 m long scintillating bars instrumented with wavelength shifting fibres and read out by different models of silicon photomultipliers have been measured at a test beam at the T9…

SuperFGD, a highly granular scintillator detector, is under construction to reduce systematic uncertainties in the T2K experiment in order to improve the sensitivity to CP-violation in neutrino oscillations. SuperFGD will be comprised of…

Large spherical scintillation detectors are playing an increasingly important role in experimental neutrino physics studies. From the instrumental point of view the primary signal response of these set-ups is constituted by the time and…

Instrumentation and Detectors · Physics 2008-11-26 Paolo Lombardi , Gioacchino Ranucci

This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section…

We present Monte Carlo (MC) simulation results from a study of a compact plastic-scintillator detector suitable for imaging fast neutrons in the 1 -- 10 MeV energy range: the miniTimeCube (mTC). Originally designed for antineutrino…