English
Related papers

Related papers: A high resolution scintillating fiber tracker with…

200 papers

Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…

Instrumentation and Detectors · Physics 2025-02-12 Shiv K. Subedi , Simon R. Cherry , Yi Qiang , Peng Peng

Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the…

Over the last decade one of the most significant technological advances made in the field of radiation detectors for nuclear medicine was the development of Silicon Photomultipler (SiPM) sensors. At present a only small number of SiPM based…

Instrumentation and Detectors · Physics 2020-08-03 Jeremy M. C. Brown

The advent of silicon photomultipliers has enabled big advances in high energy physics instrumentation, for example by allowing the construction of extremely granular hadronic calorimeters with photon sensors integrated into small…

Instrumentation and Detectors · Physics 2019-08-13 Christian Soldner

We report on the energy, timing, and pulse-shape discrimination performance of cylindrical 5 cm diameter x 5 cm thick and 7 cm diameter x 7 cm thick {\it trans}-stilbene crystals read out with the passively summed output of three different…

Instrumentation and Detectors · Physics 2020-01-08 Melinda Sweany , Peter Marleau , Chris Allwork , Gene Kallenbach , Steven Hammon

A combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows an excellent performance in the `$K_{L}$ and $\mu$ detector (KLM)' of the Belle II experiment. In this study, we present the R&D…

Instrumentation and Detectors · Physics 2024-05-22 Hongyu Zhang , Xiyang Wang , Weihu Ma , Shiming Zou , Deqing Fang , Wanbing He , Xiaolong Wang , Zhen Wang , Rui Yuan , Qibin Zheng

The existing ATLAS Tracker will be at its functional limit for particle fluences of 10^15 neq/cm^2 (LHC). Thus for the upgrades at smaller radii like in the case of the planned Insertable B-Layer (IBL) and for increased LHC luminosities…

For a long time, scintillator detectors have suffered from relatively weak spatial resolution due to various influencing factors. Additionally, the high cost of photomultiplier tubes (PMTs) has limited the widespread adoption of…

Instrumentation and Detectors · Physics 2025-04-29 S. K. Lv , C. S. Dai , D. D. Hu , T. C. Zhong , W. F. Wu , X. J. Wang

For the first time secondary scintillation, generated within the holes of a thick gas electron multiplier (TGEM) immersed in liquid argon, has been observed and measured using a silicon photomultiplier device (SiPM). 250 electron-ion pairs,…

Instrumentation and Detectors · Physics 2009-11-13 P. K. Lightfoot , G. J. Barker , K. Mavrokoridis , Y. A. Ramachers , N. J. C. Spooner

Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They…

Instrumentation and Detectors · Physics 2020-01-29 V. Mikhaylov , F. Guber , A. Ivashkin , A. Kugler , V. Kushpil , S. Morozov , O. Svoboda , P. Tlusty

The advent of both multi-messenger and time-domain astrophysics over the last decade has seen a large interest in the development of small-scale, cheap, and robust gamma-ray detectors. This has been further encouraged by the availability of…

The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two…

The NeuLAND (New Large-Area Neutron Detector) plastic-scintillator-based time-of-flight detector for 0.1-1.6 GeV neutrons is currently under construction at the Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. In its…

Instrumentation and Detectors · Physics 2023-01-11 Thomas Hensel , David Weinberger , Daniel Bemmerer , Konstanze Boretzky , Igor Gašparić , Daniel Stach , Andreas Wagner , Kai Zuber

We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of…

Plastic scintillators are widely used for the detection of elementary particles, and 3D reconstruction of particle tracks is achieved by segmenting the detector into 3D granular structures. In this study, we present a novel prototype…

A novel concept to enhance the photo-detection efficiency (PDE) of silicon photomultipliers (SiPMs) has been applied and remarkable positive results can be reported. This concept uses arrays of microlenses to cover every second SiPM pixel…

As a prototype detector for the SHiP Surrounding Background Tagger (SBT), we constructed a cell (120 cm x 80 cm x 25 cm) made from corten steel that is filled with liquid scintillator (LS) composed of linear alkylbenzene (LAB) and…

The detector of TRopIcal DEep-sea Neutrino Telescope (TRIDENT) will use large-area silicon photomultiplier (SiPM) arrays combined with photomultiplier tubes to boost photon detection efficiency and pointing capability. An…

Instrumentation and Detectors · Physics 2025-02-06 M. X. Wang , Y. Liu , Y. Q. Tan , J. N. Tang , W. H. Wu , D. L. Xu , W. Zhi , Z. Z. Zhou

A highly granular hadronic calorimeter (HCAL) based on scintillator tiles with individual readout by silicon photomultipliers (SiPMs) has been constructed by the CALICE collaboration and has been tested extensively in particle beams at…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

A fibre detector with multianode PM readout for high rate applications was developed for the HERA-B spectometer to cover the area near the beampipe. Such a detector has to operate at particle rates up to 2*10**4 mm**(-2) s**(-1) and has to…

High Energy Physics - Experiment · Physics 2007-05-23 H. B. Dreis , F. Eisele , M. Hildebrandt , B. Schmidt , A. Sponsel , M. Ziegler