English

Development of a Scintillatring Fibre Detector for HERA-B

High Energy Physics - Experiment 2007-05-23 v1

Abstract

A fibre detector with multianode PM readout for high rate applications was developed for the HERA-B spectometer to cover the area near the beampipe. Such a detector has to operate at particle rates up to 2*10**4 mm**(-2) s**(-1) and has to tolerate a radiation dosis up to 1 Mrad/y. The light output of test detectors with different scintillating fibres was measured as well as the light transport through clear fibres to the PM as a function of radiation dosis and different conditions of irradiation. The geometry of the detector is described and results for a full size prototype are presented.

Keywords

Cite

@article{arxiv.hep-ex/9805004,
  title  = {Development of a Scintillatring Fibre Detector for HERA-B},
  author = {H. B. Dreis and F. Eisele and M. Hildebrandt and B. Schmidt and A. Sponsel and M. Ziegler},
  journal= {arXiv preprint arXiv:hep-ex/9805004},
  year   = {2007}
}

Comments

18 pages, 8 figures