Related papers: Final Size Planar Edgeless Silicon Detectors for t…
We report on the development of commercially fabricated multi-chroic antenna coupled Transition Edge Sensor (TES) bolometer arrays for Cosmic Microwave Background (CMB) polarimetry experiments. CMB polarimetry experiments have deployed…
Recent progress in active-edge technology of silicon sensors enables the development of large-area tiled silicon pixel detectors with small dead space between modules by utilizing edgeless sensors. Such technology has been proven in…
The TeV energy region is currently being explored by both the ATLAS and CMS experiments of the Large Hadron Collider and phenomena beyond the Standard Model are extensively searched for. Large fractions of the parameter space of many models…
To cope with the High Luminosity LHC harsh conditions, the ATLAS inner tracker has to be upgraded to meet requirements in terms of radiation hardness, pile up and geometrical acceptance. The active edge technology allows to reduce the…
Using 2.0 cm x 2.0 cm x 0.5 cm Cadmium Telluride (CdTe) substrates from the company Acrorad, we have fabricated detectors with planar cathode contacts and 8x8 anode pixels. We investigate the I-V characteristics and energy resolution of the…
A measurement of the production cross section for a top quark pair in association with a $Z$ boson ($t\bar{t}Z$) is presented in this PhD thesis. Final states with exactly three charged leptons (electrons or muons) are used, taking into…
In order to cope with increasing lifetime radiation damage expected at collider experiments, silicon sensors are becoming increasingly thin. To achieve adequate detection efficiency, the next generation of detectors may have to operate with…
The TOTEM experiment at the LHC is dedicated to the measurement of the total pp cross section and to the study of elastic scattering and of diffractive dissociation processes. TOTEM is here presented with a general overview on the main…
The process pp$\to\ell^+\ell^-$p$^{(*)}$, with $\ell^+\ell^-$ a muon or an electron pair produced at midrapidity with mass larger than 110 GeV, has been observed for the first time at the LHC in pp collisions at $\sqrt{s} =$ 13 TeV. One of…
The CMS-TOTEM Precision Proton Spectrometer (CT-PPS) is an approved project to add tracking and timing information at approximately $\pm$210~m from the interaction point around the CMS detector. It is designed to operate at high luminosity…
3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…
The development of CdZnTe detectors with an orthogpnal coplanar anode structure has important implications for future astrophysical instrumentation. As electron-only devices, like pixel detectors, coplanar anode strip detectors can be…
New physics is being explored with the Large Hadron Collider at CERN and with Intensity Frontier programs at Fermilab and KEK. The energy scale for new physics is known to be in the multi-TeV range, signaling the need for a future collider…
Transition-edge sensors (TESs) are capable of highly accurate single particle energy measurement. TESs have been used for a wide range of photon detection applications, particularly in astronomy, but very little consideration has been given…
Photon interactions at the LHC result in striking final states with much lower hadronic activity in the central detectors than for pp interactions. In addition, the elastic exchange of a photon leads to a proton scattered at almost…
We have developed a new design of a GEM-like detector with single-layer electrodes made of a resistive kapton. This detector can operate at gains close to 10E5 even in pure Ar and Ne and if transited to discharges at higher gains they, due…
Proton radiography is a new scatheless diagnostic tool, and which provides a potential development direction for advanced hydrotesting. Recently a low energy proton radiography system has been developed at CAEP. This system has been…
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental…
We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave…
We describe recent results from CMS and TOTEM on hard diffraction, diffractive jets and jet gap jet events. We also give the first sensitivities and limits on quartic anomalous couplings and axion-like particles at high mass using the LHC…