Related papers: A proposed DAQ system for a calorimeter at the Int…
The 4th Concept detector presently being designed for the International Linear Collider introduces several innovations in order to achieve the necessary experimental goal of a detecter that is 2-to-10 times better than the already excellent…
We present a brief summary of the International Linear Collider as documented in the 2013 Technical Design Report. The Technical Design Report has detailed descriptions of the accelerator baseline design for a 500 GeV e+e- linear collider,…
High energy physics experiments in KEK/Japan rush into over KHz trigger stage. Thus, we need a successor of the data acquisition(DAQ) system that replaces the CAMAC or FASTBUS systems. To meet these needs, we have developed a DAQ system…
Precision physics at future colliders requires highly granular calorimeters to support the Particle Flow Approach for event reconstruction. This article presents a review of about 10 - 15 years of R\&D, mainly conducted within the CALICE…
The CALICE collaboration has constructed highly granular electromagnetic and hadronic calorimeter prototypes to evaluate technologies for the use in detector systems at the future International Linear Collider. These calorimeters have been…
This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling…
ATLAS LAr calorimeter will perform its Phase-I upgrade during the long shut down (LS2) in 2018, a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multichannel high-speed ADCs…
The SiD Detector is one of two validated detector designs for the future International Linear Collider. SiD features a compact, cost-constrained design for precision Higgs couplings determination, and other measurements, and sensitivity to…
The Particle Flow Algorithms adopted for future $e^{+}e^{-}$ colliders detectors and phase-II CMS upgrade require very high granularity calorimeters to deconvolve the individual contributions of particles in jets. This is especially true…
This paper presents the status of Monte Carlo simulation of one of the luminosity detectors considered for the future e+e- International Linear Collider (ILC). The detector consists of a tungsten/silicon sandwich calorimeter with pad…
The SiD Detector is one of two detector designs for the future International Linear Collider (ILC) that were validated in 2012 SiD features a compact, cost-constrained design for precision Higgs and other measurements, and sensitivity to a…
A new design of a detector module of submillimeter thickness for an electromagnetic calorimeter is presented. It is aimed to be used in the luminometers LumiCal and BeamCal in future linear e$^{+}$e$^{-}$ collider experiments. The module…
The SiD collaboration is developing a Si-W sampling electromagnetic calorimeter, with anticipated application for the International Linear Collider. Assembling the modules for such a detector will involve special bonding technologies for…
We have developed a novel data acquisition system for measuring tracking parameters of a silicon detector in a particle beam. The system is based on a commercial Analog-to-Digital VME module and a PC Linux based Data Acquisition System.…
A Forward Calorimeter (FoCal) has been proposed as part of the ALICE upgrades for data taking from 2029 onwards. The FoCal will feature a sampling electromagnetic calorimeter segmented into 110 towers supplemented by a hadron calorimeter.…
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for…
An extended version of the CALICE silicon-tungsten ECAL was tested in November 2021 at the DESY beam test facility. With 15 active layers, it featured some with a thin PCB design, and a new compact DAQ system handling all layers in a common…
Detectors for experiments at International Linear Collider require utilities such as electricity and cooling water, as well as the space to locate the relevant service facilities. In this article, a possible design of caverns for utilities…
A forward electromagnetic calorimeter (FoCal) based on SiW technology is being considered as a possible upgrade to the ALICE detector. This device should in particular feature an extremely high granularity allowing gamma/pi0 discrimination…