Related papers: Readout of GEM Detectors Using the Medipix2 CMOS P…
This contribution investigates a prototype of a TPC readout with a highly pixelated CMOS ASIC, which is an option for charged particles tracking of the ILC. A triple GEM stack was joined with a TimePix and MediPix2 chip (pixel size of…
Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of $\mu$m were measured on the GEM plane along with…
In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the…
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $\mu$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas…
The Medipix4 chip is the latest member in the Medipix/Timepix family of hybrid pixel detector chips aimed at high-rate spectroscopic X-ray imaging using high-Z materials. It can be tiled on all 4 sides making it ideal for constructing…
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which…
The concept of a hybrid readout of a time projection chamber is presented. It combines a GEM-based amplification and a pad-based anode plane with a pixel chip as readout electronics. This way, a high granularity enabling to identify…
A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…
We report the design and characterization of a CMOS pixel direct charge sensor, Topmetal-II-, fabricated in a standard 0.35um CMOS Integrated Circuit process. The sensor utilizes exposed metal patches on top of each pixel to directly…
Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low…
We present measurements with a GEM based TPC prototypes and the TimePix CMOS ASIC as charge collecting anode. Tests with a small prototype were performed in a 5 GeV electron beam at DESY. Different GEM orientations and geometries were…
For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM…
The triple GEM detector is a micropattern gas detector which consists of a primary ionisation gap and three consecutive gas electron multiplier (GEM) foils. A printed circuit board with readout strips detects the current induced by the…
Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are…
The concept of a hybrid readout of a time projection chamber is presented. It combines a GEM-based amplification and a pad-based anode plane with a pixel chip as readout electronics. This way, a high granularity enabling to identify…
Monolithic CMOS pixel detectors have emerged as competitive contenders in the field of high-energy particle physics detectors. By utilizing commercial processes they offer high-volume production of such detectors. A series of prototypes has…
We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…
CEPC (Circular Electron and Positron Collider) is a large experiment facility proposed by Chinese particle physics community. One of its running option is being the Higgs factory. Calorimeter is the main part of this experiment to measure…
Hybrid pixel sensor technology such as the Medipix3 represents a unique tool for electron imaging. We have investigated its performance as a direct imaging detector using a Transmission Electron Microscope (TEM) which incorporated a…
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of…