Related papers: A triple-GEM telescope for the TOTEM experiment
A recently approved ten-year extension of the BESIII experiment (IHEP, Beijing) motivated an upgrade program for both the accelerator and the detector. In particular, the current inner drift chamber is suffering from aging and the proposal…
The ALICE Collaboration is planning a major upgrade of its central barrel detectors to be able to cope with the increased LHC luminosity beyond 2020. In order to record at an increased interaction rate of up to 50$\,$kHz in Pb$-$Pb…
The ALICE experiment at the Large Hadron Collider at CERN is upgrading its central tracking detector, the Time Projection Chamber (TPC). The installation is foreseen during the second long shutdown of the Large Hadron Collider. The upgrade…
A GEM detector with an effective area of 30*30 cm2 has been constructed using an improved self-stretch technique, which enables an easy and fast GEM assembling. The design and assembling of the detector is described. Results from tests of…
We demonstrate three-dimensional track reconstruction of electrons in a low pressure (50 Torr) optical TPC consisting of two glass GEMs with an ITO strip readout in CF4 and CF4/Ar mixtures. The reconstructed tracks show a variety of event…
The detection of photons produced during the avalanche development in gas chambers has been the subject of detailed studies in the past. The great progresses achieved in last years in the performance of micro-pattern gas detectors on one…
Presented here are first tests of a Gaseous Photomultiplier based on a cascade of Thick GEM structures intended for gamma-ray position reconstruction in liquid Argon. The detector has a MgF$_2$ window, transparent to VUV light, and a CsI…
In this work, a fast method of vertex reconstructing for incident ions in GEM detectors was proposed. As inspired by the Time Projection Chamber (TPC), the time information of the consecutive signal samples from Front End Electronics (FEE)…
Transmission electron microscopy (TEM) has reached ~ 50 picometer resolution in a high vacuum, enabling single-atom sensitive imaging of nanomaterials. Extending this capability to gaseous environments would allow for similar visualizations…
We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors…
Systematic studies on the gain and the energy resolution have been carried out varying the voltage across the GEM foils for both single mask and double mask triple GEM detector prototypes. Variation of the gain and the energy resolution…
The main aim of the study is to perform the long-term stability test of gain of the single mask triple GEM detector. A simple method is used for this long- term stability test using a radioactive X-ray source with high activity. The test is…
The Cylindrical GEM-Inner Tracker (CGEM-IT) is the upgrade of the internal tracking system of the BESIII experiment. It consists of three layers of cylindrically-shaped triple GEMs, with important innovations with respect to the existing…
From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these…
This contribution investigates a prototype of a TPC readout with a highly pixelated CMOS ASIC, which is an option for charged particles tracking of the ILC. A triple GEM stack was joined with a TimePix and MediPix2 chip (pixel size of…
Systematic investigations including both simulation and prototype tests have been done about the interpolating resistive readout structure with GEM (Gaseous Electron Multiplier) detector. From the simulation, we have a good knowledge of the…
We have previously reported on the construction and successful operation of the novel double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric…
The ALICE Collaboration is planning a major upgrade of its central barrel detectors to be able to cope with the increased LHC luminosity beyond 2020. For the TPC, this implies a replacement of the currently used gated MWPCs (Multi-Wire…
We report on discharge probability studies with a single Gas Electron Multiplier (GEM) under irradiation with alpha particles in Ar- and Ne-based gas mixtures. The discharge probability as a function of the GEM absolute gain is measured for…
This work is proposing and exploring the use of multichannel readout electronics, already used in quality assurance for gain uniformity studies, to measure the uniformity of the induction gap in GEM based detectors. The measurement will…