English
Related papers

Related papers: A two-phase argon avalanche detector operated in a…

200 papers

A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under…

Instrumentation and Detectors · Physics 2016-12-26 Yu-Ning Zhang , Qian Liu , Hong-Bang Liu , Yi-Gang Xie , Xiao-Rui Lyu , Shi Chen , Wen-Qian Huang , Dao-Jin Hong , Yang-Heng Zheng

Two-phase Cryogenic Avalanche Detectors (CRADs) with THGEM multipliers, optically read out with Geiger-mode APDs (GAPDs), were proposed as potential technique for charge recording in rare-event experiments. In this work we report on the…

Instrumentation and Detectors · Physics 2014-08-20 A. Bondar , A. Buzulutskov , A. Dolgov , L. Shekhtman , E. Shemyakina , A. Sokolov , A. Breskin , D. Thers

A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…

Physical principles of performance and main characteristics of a novel avalanche photodetector developed on the basis of MOS(metal-oxide-silicon) technology is presented. The photodetector contains a semitransparent gate electrode and a…

High Energy Physics - Experiment · Physics 2007-05-23 Z. Ya. Sadygov , M. K. Suleimanov , T. Yu. Bokova

New light particles may be produced in large numbers in the far-forward region at the LHC and then decay to dark matter, which can be detected through its scattering in far-forward experiments. We consider the example of invisibly-decaying…

High Energy Physics - Phenomenology · Physics 2021-04-28 Brian Batell , Jonathan L. Feng , Sebastian Trojanowski

We report the measurement of longitudinal electron diffusion coefficients in liquid argon for electric fields between 100 and 2000 V/cm with a gold photocathode as a bright electron source. The measurement principle, apparatus, and data…

For the SPECTRAP experiment at GSI, Germany, detectors with Single-Photon counting capability in the visible and near-infrared regime are required. For the wavelength region up to 1100 nm we investigate the performance of 2x2 mm^2 avalanche…

Instrumentation and Detectors · Physics 2012-03-06 R. Jöhren , R. Berendes , W. Buglak , D. Hampf , V. Hannen , J. Mader , W. Nörtershäuser , R. Sánchez , C. Weinheimer

We study the potentialities of a 50 liter liquid argon TPC prototype operated at the CERN WANF neutrino beam. We concentrate on the selection and reconstruction of quasi-elastic events and measure the cross section for this reaction.

High Energy Physics - Experiment · Physics 2007-05-23 A. Martinez de la Ossa

Large mass single-electron-resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CE$\nu$NS). Here, we present results from a novel 100 g…

Instrumentation and Detectors · Physics 2021-08-04 V. Iyer , N. Mirabolfathi , G. Agnolet , H. Chen , A. Jastram , F. Kadribasic , V. K. S. Kashyap , A. Kubik , M. Lee , R. Mahapatra , B. Mohanty , H. Neog , M. Platt

Systematic uncertainties in accelerator oscillation neutrino experiments arise mostly from nuclear models describing neutrino-nucleus interactions. To mitigate these uncertainties, we can study neutrino-nuclei interactions with detectors…

Instrumentation and Detectors · Physics 2023-10-31 R. M Amarinei , F. Sánchez , E. Roe , S. Bordoni , L. Giannessi , T Lux , E. Radicioni

The operation of gas detectors is often limited by secondary effects, originating from avalanche-induced photons and ions. Ion backflow is one of the effects limiting the operation of a gas detector at high flux, by giving rise to space…

We present a Photon-Assisted Cascaded Electron Multipliers (PACEM) which has a potential for ion back-flow blocking in gaseous radiation detectors: the avalanche from a first multiplication stage propagates to the successive one via its…

Instrumentation and Detectors · Physics 2009-11-11 J. F. C. A. Veloso , F. D. Amaro , J. M. F. dos Santos , A. Breskin , A. Lyashenko , R. Chechik

The operating principle and performances of the Multi-layer Thick Gaseous Electron Multiplier (M-THGEM) is presented. The M-THGEM is a novel hole-type gaseous electron multiplier produced by multi-layer printed circuit board technology; it…

Instrumentation and Detectors · Physics 2016-06-24 M. Cortesi , S. Rost , W. Mittig , Y. Ayyad Limonge , D. Bazin , J. Yurkon , A. Stolz

A study of the dynamics of the positive charges in liquid argon has been carried out in the context of the future massive time projection chambers proposed for dark matter and neutrino physics. Given their small mobility coefficient in…

Instrumentation and Detectors · Physics 2017-05-26 L. Romero , R. Santorelli , B. Montes

We discuss the operational principle and performance of new micro-pattern gaseous detectors based on the multi-layer Thick Gaseous Electron Multiplier (M-THGEM) concept coupled to a needle-like anode. The new gas avalanche structure aims at…

Instrumentation and Detectors · Physics 2019-08-08 Jaspreet Singh Randhawa , Marco Cortesi , Wolfgang Mittig , Thomas Wierzbicki , Alejandro Gomez

In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such…

Instrumentation and Detectors · Physics 2014-11-18 A. Blatter , A. Ereditato , C. -C. Hsu , S. Janos , I. Kreslo , M. Luethi , C. Rudolf von Rohr , M. Schenk , T. Strauss , M. S. Weber , M. Zeller

The Argon Dark Matter experiment is a ton-scale double phase argon Time Projection Chamber designed for direct Dark Matter searches. It combines the detection of scintillation light together with the ionisation charge in order to…

Low gain avalanche detectors (LGADs) deliver excellent timing resolution, which can mitigate mis-assignment of vertices associated with pileup at the High Luminosity LHC and other future hadron colliders. The most highly irradiated LGADs…

Instrumentation and Detectors · Physics 2024-01-01 Josef Sorenson , Martin Hoeferkamp , Gregor Kramberger , Sally Seidel , Jiahe Si

The Gas Electron Multiplier detectors with wire and metallic electrodes, with a gas filling in the gap between them were proposed and tested. The main advantage of these Gas Electron Multipliers compared to standard ones consists in their…

Instrumentation and Detectors · Physics 2010-12-22 B. M. Ovchinnikov , V. V. Parusov , Yu. B. Ovchinnikov

Commercial photon-counting modules based on actively quenched solid-state avalanche photodiode sensors are used in a wide variety of applications. Manufacturers characterize their detectors by specifying a small set of parameters, such as…

Quantum Physics · Physics 2017-09-12 Mario Stipčević , Bradley G. Christensen , Paul G. Kwiat , Daniel J. Gauthier
‹ Prev 1 8 9 10 Next ›