Related papers: Bulk Etch Rate Measurements and Calibrations of Pl…
We developed a new method for determining the bulk etch rate velocity based on both cone height and base diameter measurements of the etched tracks. This method is applied here for the calibration of CR39 and Makrofol nuclear track…
Several improvements were made for Nuclear Track Detectors (NTDs) used for environmental studies and for particle searches. A new method was used to determine the bulk etch rate of CR39 and Makrofol NTDs. It is based on the simultaneous…
The calibration of the CR39 and Makrofol Nuclear Track Detectors of the MoEDAL experiment at the CERN-LHC was performed by exposing stacks of detector foils to heavy ion beams with energies ranging from 340 MeV/nucleon to 150 GeV/nucleon.…
The nuclear track detector CR39 was calibrated with different ions of different energies. Due to the low detection threshold (Z/beta~6e) and the good charge resolution (sigma_Z ~ 0.2e for 6e < Z/beta <83e with 2 measurements), the detector…
We present the calibration of the Makrofol nuclear detector using Pb ions of 158 AGeV.
We report the measurement of the fragmentation cross sections in high-energy nucleus-nucleus collisions using the 158 A GeV Pb beam from the CERN-SPS. The fragments have charges changed from that of the incident projectile nucleus by…
We used Nuclear Track Detectors (NTD) CR39 and Makrofol for many purposes: i) Exposures at the SPS and at lower energy accelerator heavy ion beams for calibration purposes and for fragmentation studies. ii) Searches for GUT and Intermediate…
We report on the measurements of the total charge changing fragmentation cross sections in high-energy nucleus-nucleus collisions using Fe, Si and Pb incident ions. Several stacks of CR39 nuclear track detectors with different target…
We are investigating the total charge changing cross-section of 12C by using the CR39 nuclear track detector. Target sandwiched with CR39 of 5 cm x 5 cm area was irradiated with $^{12}$C ion at 55 MeV/n and 135 MeV/n at the Wakasa wan…
A new diagnosis method for high energy ions utilizing a single CR-39 detector mounted on plastic plates is demonstrated to identify the presence of the high energy component beyond the CR-39's detection threshold limit. On irradiation of…
A stack of CR39 (C12H18O7)n nuclear track detectors with a Cu target was exposed to a 158 A GeV lead ion beam at the CERN-SPS, in order to study the fragmentation properties of lead nuclei. Measurements of the total, break-up and pick-up…
New measurements of the total and partial fragmentation cross sections in the energy range 0.3-10 A GeV of Fe^{26+}, Si^{14+} and C^{6+} beams on polyethylene, CR39 and aluminum targets are presented. The exposures were made at Brookhaven…
In this paper we report a search for intermediate mass magnetic monopoles and nuclearites using CR39 and Makrofol Nuclear Track Detectors (NTDs) of the SLIM large area experiment, 440 m^2 exposed at the high altitude laboratory of…
We present new measurements of the total and partial fragmentation cross sections in the energy range 0.3-10 A GeV of 56Fe, 28Si and 12C beams on polyethylene, CR39 and aluminum targets. The exposures were made at BNL, USA and HIMAC, Japan.…
To improve the ability of particle identification of the RIBLL2 separator at the HIRFL-CSR complex, a new high-performance detector for measuring fragment starting time and position at the F1 dispersive plane has been constructed and…
Atomic masses of seven $T_z=-1$, $fp$-shell nuclei from $^{44}$V to $^{56}$Cu and two low-lying isomers, $^{44m}$V ($J^\pi=6^+$) and $^{52m}$Co ($J^\pi=2^+$), have been measured with relative precisions of $1-4\times 10^{-7}$ with…
This works presents results of activation-aided determination of threshold reaction rates in 92 209Bi, natPb, 197Au, 181Ta, 169Tm, natIn, 93Nb, 64Zn, 65Cu, 63Cu, 59Co, 19F, and 12C samples and in 121 27Al samples. All the samples were…
The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a…
The response of an array of plastic phoswich detectors to ions of $1\le Z\le 18$ has been measured from $E/A$=12 to 72 MeV. The detector response has been parameterized by a three parameter fit which includes both quenching and high energy…