Related papers: Semiconductor High-Energy Radiation Scintillation …
The Integrating Miniature Piggyback for Impulsive Solar Hard X-rays (IMPISH) is a solar X-ray spectrometer that features large-area scintillators, fast readout electronics, and good energy resolution in the hard X-ray band. IMPISH is a…
Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high…
We present the design and current status of SPLENDOR, a novel detector platform that combines narrow-gap semiconductor targets with low-noise charge readout to achieve sensitivity to dark matter energy deposits well below the eV scale.…
Scintillation, the process of converting high-energy radiation to detectable visible light, is pivotal in advanced technologies spanning from medical diagnostics to fundamental scientific research. Despite significant advancements toward…
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the…
High-frequency sine wave gating (SWG) InGaAs/InP single-photon detectors (SPDs) are widely used for synchronous near-infrared single-photon detection. For practical use, the size of SPD is one of the most concerning features for system…
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified…
A new instrument for high resolution imaging of fast-neutrons is presented here. It is designed for energy selective radiography in nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. The device presented here is based on hydrogenous…
For a long time, scintillator detectors have suffered from relatively weak spatial resolution due to various influencing factors. Additionally, the high cost of photomultiplier tubes (PMTs) has limited the widespread adoption of…
Fast emitting polymeric scintillators are requested in advanced applications where high-speed detectors with large signal-to-noise ratio are needed. However, their low density implies a weak stopping power of high energy radiations, thus a…
GAGG(Ce) is a novel scintillator with a fast response and high light output without a hygroscopic nature. It is expected to be a useful detector for charged particles at high-counting rates. However, the response of the GAGG(Ce)…
A few-micron thick structure that shows nearly 100% resonant polarized absorptance at a predefined midinfrared wavelength is designed and simulated. Like resonant-cavity enhanced photodetector structure, it contains a thin absorber enclosed…
Semiconductor emitter can possibly achieve sharp cutoff wavelength due to its intrinsic bandgap absorption and almost zero sub-bandgap emission without doping. A germanium wafer based selective emitter with front-side antireflection and…
A compact gamma-ray detector module was developed and characterized for spectroscopic applications across a wide energy range. The detector comprises a 4x4 array of silicon photomultipliers (SiPMs, Hamamatsu MPPC S13360-3050) coupled with…
One of the most promising approaches for the next generation of neutrino experiments is the realization of large hybrid Cherenkov/scintillation detectors made possible by recent innovations in photodetection technology and liquid…
The scintillating properties of active materials used in high energy and particle physics experiments play an important role regarding the performances of both calorimeters and experiments. Two scintillator materials, a scintillating glass…
In recent experiments, inorganic scintillators have been used to study the decays of exotic nuclei, providing an alternative to silicon detectors and enabling measurements that were previously impossible. However, proper use of these…
A method of scanning mid-IR-laser microscopy has recently been proposed for the investigation of large-scale electrically and recombination-active defects in semiconductors and non-destructive inspection of semiconductor materials and…
Conceiving the possibility of using plastic scintillator bars as robust detectors for antineutrino detection for the remote reactor monitoring and nuclear safeguard application we study expected basic performance by Monte Carlo simulation.…
This is a brief review of liquid scintillators, an important technology for detection of ionizing radiation. We will first review the basic mechanisms of light production in most organic liquid scintillators. For most practical detector…