English
Related papers

Related papers: Gamma Ray Spectroscopy with Scintillation Light in…

200 papers

Detection of photons with scintillating inorganic crystals in the high-energy range (> 0.1 MeV) will be discussed, making a comparison with other available methods. Energy resolutions up to 2 % at 662 keV and fast decay time of the order of…

Instrumentation and Detectors · Physics 2025-05-13 M. Bonesini

We have developed a compact Compton gamma-ray imager with a large field of view and a low channel-count that is capable of quickly localizing gamma-ray sources in the few hundred keV - several MeV range. The two detector planes (scatter and…

Instrumentation and Detectors · Physics 2015-06-18 A. M. L. MacLeod , P. J. Boyle , D. S. Hanna , P. R. B. Saull , L. E. Sinclair , H. C. J. Seywerd

Intense infrared (IR) light emission from liquid Ar-Xe mixtures has been observed using 12 keV electron-beam excitation. The emission peaks at a wavelength of 1.18 $\mu$m and the half-width of the emission band is 0.1 $\mu$m. Maximum…

Instrumentation and Detectors · Physics 2015-11-25 A. Neumeier , T. Dandl , T. Heindl , A. Himpsl , H. Hagn , M. Hofmann , L. Oberauer , W. Potzel , S. Roth , S. Schönert , J. Wieser , A. Ulrich

Liquid xenon detectors such as XENON10 and XENON100 obtain a significant fraction of their sensitivity to light (<10 GeV) particle dark matter by looking for nuclear recoils of only a few keV, just above the detector threshold. Yet in this…

Instrumentation and Methods for Astrophysics · Physics 2011-01-27 Peter Sorensen

New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating…

Scintillation light produced in liquid xenon (LXe) by alpha particles, electrons and gamma-rays was detected with a large area avalanche photodiode (LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a function of…

Instrumentation and Detectors · Physics 2009-11-11 K. Ni , E. Aprile , D. Day , K. L. Giboni , J. A. M. Lopes , P. Majewski , M. Yamashita

The scintillation efficiency of liquid xenon for nuclear recoils has been measured to be nearly constant in the recoil energy range from 140 keV down to 5 keV. The average ratio of the efficiency for recoils to that for gamma-rays is found…

Instrumentation and Detectors · Physics 2009-11-11 V. Chepel , V. Solovov , F. Neves , A. Pereira , P. J. Mendes , C. P. Silva , A. Lindote , J. Pinto da Cunha , M. I. Lopes , S. Kossionides

A detector using liquid Xenon in the scintillation mode is studied for Positron Emission Tomography (PET). The specific design aims at taking full advantage of the liquid Xenon properties. It does feature a promising insensitive to any…

PET is a functional imaging technique based on detection of annihilation photons following beta decay producing positrons. In this paper, we present the concept of a new PET system for preclinical applications consisting of a ring of twelve…

Instrumentation and Detectors · Physics 2015-03-19 A. Miceli , P. Amaudruz , F. Benard , D. A. Bryman , L. Kurchaninov , J. P. Martin , A. Muennich , F. Retiere , T. J. Ruth , V. Sossi , A. J. Stoessl

We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a…

Instrumentation and Detectors · Physics 2015-10-28 L. Arazi , A. E. C. Coimbra , E. Erdal , I. Israelashvili , M. L. Rappaport , S. Shchemelinin , D. Vartsky , J. M. F. dos Santos , A. Breskin

First imaging results in liquid xenon of a Liquid Hole Multiplier (LHM) coupled to a Quad-Silicon Photomultiplier (SiPM) array are presented. Ionization electrons deposited in the noble liquid by 5.5 MeV alpha particles, are collected into…

Instrumentation and Detectors · Physics 2019-02-20 E. Erdal , A. Tesi , D. Vartsky , S. Bressler , L. Arazi , A. Breskin

Xenon-doped liquid argon has been proposed as a good alternative to pure liquid argon in scintillation detectors. In this study, we report on the measurement of the time profile of scintillation light emitted from xenon-doped liquid argon…

Instrumentation and Detectors · Physics 2021-02-23 Cristiano Galbiati , Xinran Li , Jingyu Luo , Daniel R. Marlow , Hanguo Wang , Yi Wang

A light-yield calibration of an NE 213A organic liquid scintillator detector has been performed using both monoenergetic and polyenergetic gamma-ray sources. Scintillation light was detected in a photomultiplier tube, and the corresponding…

Scintillation properties of the new Tl2LaCl5: xCe3+ where x = 0, 0.5, 1 and 10 mole % (TLC: Ce3+) single crystals are presented. Two zones vertical Bridgman technique is used for the growth of this scintillation material. High Z-number (79)…

Materials Science · Physics 2017-04-05 H. J. Kim , Gul Rooh , Sunghwan Kim

In the present paper, we report on our developments of liquid xenon detectors for medical imaging, positron emission tomography and single photon imaging, in particular. The results of the studies of several photon detectors…

Instrumentation and Detectors · Physics 2017-08-23 V. Chepel , M. I. Lopes , V. Solovov , R. Ferreira Marques , A. J. P. L. Policarpo

PETALO (Positron Emission TOF Apparatus with Liquid xenOn) is a project that uses liquid xenon as a scintillation medium, silicon photomultipliers as a readout and fast electronics to provide a significant improvement in PET-TOF technology.…

Instrumentation and Detectors · Physics 2023-11-17 Nerea Salor Iguiñiz

LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics, based on a liquid xenon time projection chamber with charge and light readout. The energy and direction of an incident gamma-ray is reconstructed from the…

Astrophysics · Physics 2009-10-31 U. Oberlack , E. Aprile , A. Curioni , K. Giboni

This work investigates the capability of TMA ((CH3)3N) molecules to shift the wavelength of Xe VUV emission (160-188 nm) to a longer, more manageable, wavelength (260-350 nm). Light emitted from a Xe lamp was passed through a gas chamber…

In gamma ray imaging, a scintillation crystal is typically used to convert the gamma radiation into visible light. Photosensors are used to transform this light into measurable signals. Several types of photosensors are currently in use…

Ton-scale liquid xenon detectors operated in two-phase mode are proposed and being constructed recently to explore the favored parameter space for the Weakly Interacting Massive Particles (WIMPs) dark matter. To achieve a better light…

Instrumentation and Detectors · Physics 2014-05-13 Y Wei , Q Lin , X Xiao , K Ni