Related papers: Beam Profile Measurements and Simulations of the P…
Imaging biological molecules in the gas-phase requires novel sample delivery methods, which generally have to be characterized and optimized to produce high-density particle beams. A non-destructive characterization method of the transverse…
The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…
Measurement of stray light in a complex optical system can be a complex task. We developed a method to measure coherent stray light inside an assembled device, determining all stray light sources and their relative contribution. The method…
The wavefront measurement of a light beam is a complex task, which often requires a series of spatially resolved intensity measurements. For instance, a detector array may be used to measure the local phase gradient in the transverse plane…
We describe an apparatus used to measure the triple-correlation term (\D \hat{\sigma}_n\cdot p_e\times p_\nu) in the beta-decay of polarized neutrons. The \D-coefficient is sensitive to possible violations of time reversal invariance. The…
With electron beam durations down to femtoseconds and sub-femtoseconds achievable in current state-of-the-art accelerators, longitudinal bunch length diagnostics with resolution at the attosecond level are required. In this paper, we…
The International Linear Collider is a planned electron-positron linear collider with its positron source producing positrons by aiming undulator radiation onto a rotating target. The resulting, highly divergent positron beam requires…
Test beam measurements at the test beam facilities of DESY have been conducted to characterise the performance of the EUDET-type beam telescopes originally developed within the EUDET project. The beam telescopes are equipped with six sensor…
Linear collider designs foresee some bends of about 5-10 mrad. The spin precession angle of one TeV electrons on 10 mrad bend is 23.2 rad and it changes proportional to the energy. Measurement of the spin direction using Compton scattering…
A compact beam-profile monitor was constructed using a linear contact image sensor attached to a plastic scintillator and tested using a 230 MeV proton beam. The results indicate that the beam distribution can be obtained in real-time, and…
The study of elastic bremsstrahlung and electron tagging in electron-proton or ion collisions is gaining importance with the planned construction of several experimental facilities focused on deep-inelastic scattering (DIS) measurements.…
The International Linear Collider (ILC) is a future electron/positron collider at the energy frontier. Its physics goals are clearly focused on precision measurements at the electroweak scale and beyond. Beam energy and beam polarisation…
Laser beam quality is a key parameter for both industry and science. However, the most common measure, the M2 parameter, requires numerous intensity spatial-profiles for its determination. This is particularly inconvenient for modelling the…
Electron beam probe (EBP) is a new principle detector, which makes use of a low-intensity and low-energy electron beam to measure the transverse profile, bunch shape, beam neutralization and beam wake field of an intense beam with small…
Liquid xenon (LXe) is a very attractive material as a detection medium for ionization detectors due to its high density, high atomic number, and low energy required to produce electron-ion pairs. Therefore it has been used in several…
Detectors planned for use at the Large Hadron Collider will operate in a radiation field produced by beam collisions. To predict the radiation damage to the components of the detectors, prototype devices are irradiated at test beam…
Transition-edge sensors (TESs) are capable of highly accurate single particle energy measurement. TESs have been used for a wide range of photon detection applications, particularly in astronomy, but very little consideration has been given…
A simple yet precise optical technique for measuring the ambipolar carrier mobility in semiconductors is presented. Using tightly focused Gaussian laser beams in a photo-reflectance system, the modulated reflectance signal is measured as a…
We describe a study of high-energy Compton beam polarimeters for the future e+e- linear collider machine TESLA. A segment of the beam delivery system has been identified, which is aligned with the e+e- collision axis and which has a…
An instrument has been developed for precision controlled exposures of electronic devices and material samples in particle beams. The instrument provides simultaneously a real time record of the profile of the beam and the fluence received.…