English
Related papers

Related papers: Performance of three-photon PET imaging: Monte Car…

200 papers

Study of certain angular correlations in the three-photon annihilations of the triplet state of positronium, the electron-positron bound state, may be used as a probe of potential CP and CPT-violating effects in the leptonic sector. We…

Instrumentation and Detectors · Physics 2020-06-02 Aleksander Gajos

This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration…

The purpose of this work is to develop viable procedures for verifying the applicability of personalized dosimetry in computed tomography (CT) using Monte Carlo-based simulations. Mobile equipment together with customized software was…

This paper presents a novel image reconstruction pipeline for three-gamma (3-{\gamma}) positron emission tomography (PET) aimed at improving spatial resolution and reducing noise in nuclear medicine; the proposed Direct3{\gamma} pipeline…

Medical Physics · Physics 2025-06-23 Youness Mellak , Alexandre Bousse , Thibaut Merlin , Debora Giovagnoli , Dimitris Visvikis

Compact gamma cameras with a square-shaped monolithic scintillator crystal and an array of silicon photomultipliers (SiPMs) are actively being developed for applications in areas such as small animal imaging, cancer diagnostics and…

Medical Physics · Physics 2017-04-26 A. Morozov , F. Alves , J. Marcos , R. Martins , L. Pereira , V. Solovov , V. Chepel

A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs…

Measured response functions and low photon yield spectra of silicon photomultipliers (SiPM) were compared to multi-photoelectron pulse-height distributions generated by a Monte Carlo model. Characteristic parameters for SiPM were derived.…

Nuclear Experiment · Physics 2008-11-26 S. Sanchez Majos , P. Achenbach , J. Pochodzalla

PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements…

Photon-number resolving detectors with hundreds of pixels are now readily available, while the characterization of these detectors using detector tomography is computationally intensive. Here, we present a modified detector tomography model…

Quantum Physics · Physics 2023-11-22 Dong-Sheng Liu , Jia-Qi Wang , Chang-Ling Zou , Xi-Feng Ren , Guang-Can Guo

In gamma ray imaging, a scintillation crystal is typically used to convert the gamma radiation into visible light. Photosensors are used to transform this light into measurable signals. Several types of photosensors are currently in use…

Positron Emission Tomography scan images are extensively used in radiotherapy planning, clinical diagnosis, assessment of growth and treatment of a tumor. These all rely on fidelity and speed of detection and delineation algorithm. Despite…

Medical Physics · Physics 2017-10-25 Yeman B. Hagos , Vu H. Minh , Saed Khawaldeh , Usama Pervaiz , Tajwar A. Aleef

We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on…

Recent studies of positron emission tomography (PET) devices have shown that the detection of polarization-correlated annihilation quanta can potentially reduce the background and creation of false lines of response (LORs) leading to…

Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental…

A triple-GEM detector with two-dimensional readout is developed. The detector provides high position resolution for powder diffraction experiments at synchrotron radiation. Spatial resolution of the detector is measured in the lab using a…

Instrumentation and Detectors · Physics 2017-04-12 Y. L. Zhang , H. R. Qi , Z. W. Wen , H. Y. Wang , Q. Ouyang , Y. B. Chen , J. Zhang , B. T. Hu

Many optimization techniques have been invented to reduce the noise that is inherent in Monte Carlo radiative transfer simulations. As the typical detectors used in Monte Carlo simulations do not take into account all the information…

Astrophysics · Physics 2009-11-13 Maarten Baes

Monte Carlo Simulation (MCS) is a state-of-the-art technique in designing sophisticated apparatus for various applications in science and technology. We adopted MCS based on GEANT (GEometry ANd Tracking) in order to design a simple…

Medical Physics · Physics 2010-06-30 Nagendra Nath Mondal

In the present work we describe the design, construction, and testing of the optical prototype developed for the BOLDPET project, with the objective of creating a PET detection module with high spatial and time resolution. The BOLDPET…

Positron Emission Tomography (PET) scan images are one of the bio medical imaging techniques similar to that of MRI scan images but PET scan images are helpful in finding the development of tumors.The PET scan images requires expertise in…

Neural and Evolutionary Computing · Computer Science 2013-02-27 A. Meena , K. Raja