Related papers: 100 ps time-of-flight resolution of Dielectric Res…
Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of…
The HARP system of resistive plate chambers (RPCs) was designed to perform particle identification by the measurement of the difference in the time-of-flight of different particles. In previous papers an apparent discrepancy was shown…
The applications of Resistive Plate Chambers (RPCs) have recently been extended by the development of counters with time resolution below 100 ps sigma for minimum ionising particles. Applications to HEP experiments have already taken place…
A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A…
Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…
The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the…
In this work we describe some recent results concerning the application of Resistive Plate Chambers operated in avalanche mode at atmospheric pressure for high-resolution time-of-flight measurements. A combination of multiple, mechanically…
The ALICE Time-Of-Flight (TOF) detector at LHC is based on the Multigap Resistive Plate Chambers (MRPCs). The TOF performance during LHC Run 2 is here reported. Particular attention is given to the improved time resolution reached by TOF…
A four-gap glass RPC with 0.3mm gap size was tested with hadron beam as a time-of-flight detector having a time resolution of ~ 100ps. A thickness of the detector together with front-end electronics is ~ 12mm. Results on time resolution…
The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…
We have developed multi-gap resistive plate chambers (MRPCs) with 2.5 x 200 cm2 readout strips for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. These chambers consist of 2 stacks and 5 gas gaps per stack, in…
Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…
For precise start time determination a Beam Fragmentation T$_0$ Counter (BFTC) is under development for the Time-of-Flight Wall of the Compressed Baryonic Matter Spectrometer (CBM) at the Facility for Antiproton and Ion Research (FAIR) at…
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…
In order to test the performance of detector/prototype in environment of laboratory, we design and build a larger area ($90\times52$ $cm^2$) test platform of cosmic ray based on well-designed Multi-gap Resistive Plate Chamber (MRPC) with an…
A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the…
A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an…
A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…
A challenging goal of 20 ps for the total time resolution of the Multi-gap Resistive Plate Chambers (MRPCs) system has been recently addressed by high energy physics experiments. In order to meet this requirement, one should have a deeper…
Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…