English
Related papers

Related papers: IDeF-X ASIC for Cd(Zn)Te spectro-imaging systems

200 papers

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of…

Future experiments of nuclear and particle physics are moving towards the high luminosity regime, in order to access suppressed processes like rare B decays or exotic charmonium resonances. In this scenario, high rate capability is a key…

Instrumentation and Detectors · Physics 2015-02-18 M. Cardinali , O. Corell , M. I. Ferretti Bondy , M. Hoek , W. Lauth , C. Rosner , C. Sfienti , M. Thiel

The LUXE experiment aims at studying high-field QED in electron-laser and photon-laser interactions, with the 16.5 GeV electron beam of the European XFEL and a laser beam with power of up to 350 TW. The experiment will measure the spectra…

High Energy Physics - Experiment · Physics 2022-10-19 Veta Ghenescu

As an in-house instrument developmental activity at ARIES, the 4Kx4K CCD Imager is designed and developed as a first-light instrument for the axial port of the 3.6m DOT. The f/9 beam of the telescope having a plate-scale of ~ 6.4 arc-sec/mm…

Instrumentation and Methods for Astrophysics · Physics 2017-11-16 S. B. Pandey , R. K. S. Yadav , Nandish Nanjappa , Shobhit Yadav , B. Krishna Reddey , Sanjeet Sahu , R. Srinivasan

In order to achieve the driver function for several types of scientific CCD detector from E2V Co Ltd, and decreasing the size of electronics of CCD detector system, an Application-specified Integrated Circuit (ASIC) was designed. It…

Instrumentation and Detectors · Physics 2018-06-04 Jie Gao , Dong-xu Yang , Yi Feng , Guang-yu Zhang , Wen-qing Qu , Jian-min Wang , Hong-fei Zhang , Jian Wang

Cluster counting dN/dx is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good pion-kaon separation over a broad momentum range is…

Instrumentation and Detectors · Physics 2026-05-21 Jiajin Ge , Chihao Li , Can Suslu , Yuxiang Guo , Emmett Salzer , Tiesheng Dai , Jianming Qian , Bing Zhou , Junjie Zhu

The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$\Phi$NE collider at LNF,…

The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES…

Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $\mu$eV mass range with…

The Large High Altitude Air Shower Observatory (LHAASO) is designed for high energy gamma ray and cosmic ray detection. A Water Cherenkov Detector Array which is sensitive to gamma ray showers above a few hundred GeV is proposed to survey…

Instrumentation and Detectors · Physics 2016-03-14 Jianfeng Liu , Lei Zhao , Li Yu , Yu Liang , Jiajun Qin , Yunfang Yang , Weihao Wu , Shubin Liu , Qi An

The Advanced X-ray Imaging Satellite (AXIS) is a NASA probe class mission concept designed to deliver arcsecond resolution with an effective area ten times that of Chandra (at launch). The AXIS focal plane features an MIT Lincoln Laboratory…

For the purpose of withstanding very high radiation doses, silicon pixel sensors with a 3D electrode geometry are being developed. Detectors of this kind are highly interesting for harch radiation environments such as expected in the High…

The present article introduces a novel ASIC architecture, designed in the context of the ATLAS Tile Calorimeter upgrade program for the High-Luminosity phase of the Large Hadron Collider at CERN. The architecture is based on…

Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now…

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to…

Instrumentation and Detectors · Physics 2021-06-02 T. Guruswamy , L. Gades , A. Miceli , U. Patel , O. Quaranta

Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E >= 5keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent…

In recent years, the performance of Scientifc Complementary Metal Oxide Semiconductor (sCMOS) sensors has been improved signifcantly. Compared with CCD sensors, sCMOS sensors have various advantages, making them potentially better devices…

Instrumentation and Methods for Astrophysics · Physics 2022-10-05 Qinyu Wu , Zhenqing Jia , Wenxin Wang , Zhixing Ling , Chen Zhang , Shuangnan Zhang , Weimin Yuan

In this paper, we propose a novel Automatic and Scalable Face Detector (ASFD), which is based on a combination of neural architecture search techniques as well as a new loss design. First, we propose an automatic feature enhance module…

Computer Vision and Pattern Recognition · Computer Science 2020-04-01 Bin Zhang , Jian Li , Yabiao Wang , Ying Tai , Chengjie Wang , Jilin Li , Feiyue Huang , Yili Xia , Wenjiang Pei , Rongrong Ji

A monolithic silicon pixel ASIC prototype, produced in 2024 as part of the Horizon 2020 MONOLITH ERC Advanced project, was tested with a 120 GeV/c pion beam. The ASIC features a matrix of hexagonal pixels with a 100 \mu m pitch, read by…

A CdTe double-sided strip detector (CdTe-DSD) is an ideal device for imaging and spectroscopic measure- ments in the hard X-ray range above 10 keV. Recent development enables us to realize an imager with a detection area of ~10 cm${^2}$. An…