Related papers: Phase boundary detection for dilution refrigerator…
This work aims to demonstrate that two arrays of Lumped Element Kinetic Inductance Detectors (LEKIDs), when employed in filled array configuration and separated by an external linear polarizer oriented at 45 degrees, can achieve the…
The capacitance of the charge collection node of a sensor system is an important parameter for the design of the analog front-end electronics. The analog front-end of high-granularity sensors like for example hybrid pixel detectors need to…
This paper demonstrates the use of voltage noise thermometry, with a cross-correlation technique, as a dissipation-free method of thermometry inside a CMOS integrated circuit (IC). We show that this technique exhibits broad agreement with…
Precise temperature monitoring -- to the level of a few milli-Kelvin -- is essential for the operation of large-scale cryostats requiring a recirculation system. In particular, the performance of Liquid Argon Time Projection Chambers --…
A major challenge in operating multi-qubit quantum processors is to mitigate multi-qubit coherent errors. For superconducting circuits, besides crosstalk originating from imperfect isolation of control lines, dispersive coupling between…
A new simple entanglement measurement method is proposed for the bright EPR beams generated from a non-degenerate optical parametric amplifier operating at deamplification. Due to the output signal and idler modes are frequency degenerate…
Using only elementary calculus we prove that the balanced homodyne detector measures the quadrature phase amplitude of a signal. More precisely, after the measurement of photon numbers $l$, the collapse of the composite state of a strong…
We experimentally demonstrate background-free, hyperfine-level-selective measurements of individual Cs atoms by simultaneous cooling to $5.3~\mu\rm K$ and imaging on the $6s_{1/2}\rightarrow 5d_{5/2}$ electric-quadrupole transition. We…
An improved phase retrieval method based Hilbert transform is introduced to quantitatively calculate the phase distribution from distorted fringe pattern. Also phase measurement deflectomety are widely used in specular type samples. The…
Primary power standards in the microwave domain are realized using a calorimetric technique, usually identified with the used measurement system, i.e., the microcalorimeter. It is adjusted for measurement of power ratios with a relative…
We present an application of a quadrature phase interferometer to the measurement of the angular position of a parallel laser beam with interferometric precision. In our experimental realization we reach a resolution of 6.8e-10 rad (1.4e-4…
We propose a method of measuring diffusion of the relative phase between two Bose-Einstein condensates occupying different nuclear or spin hyperfine states coupled by a two-photon transition via an intermediate level. Due to the macroscopic…
In this paper, the capacitance of a parallel plate air-gap rectangular capacitor, and a unit cube capacitor have been calculated. Because of its generality and simplicity, the method of moments (MOM) Technique is utilized. In order to…
The Laboratory of Metrology in Electrical Standards of Inmetro (Lampe) has built, in 2010, a transformer which is able to perform inductive voltage divider ratio calibrations using the bootstrap method. This transformer was idealized…
Heat flow control is essential for widespread applications of heating, cooling, energy conversion and utilization. Here we demonstrate the first observation of temperature-gated thermal rectification in vanadium dioxide beams, in which an…
Linear Hall sensors are a cost-effective alternative to optical encoders for measuring the rotor positions of actuators, with the main challenge being that they exhibit position-dependent inaccuracies resulting from manufacturing…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
Silicon double paddle osillators (DPO) have been successfully used for measuring the elastic properties of amorphous films down to 10 mK (see for example \cite{Fefferman16,Liu14}). Until now, our group has used a wet dilution refrigerator…
Recent experiments in cosmology, particularly those aimed at detecting the faint, redshifted, global 21 cm hydrogen line (depth < ~200 mK, z > 7.5), have imposed stringent new requirements on radiometer calibration. In this work, we present…
We demonstrate experimentally that a hybrid single-electron transistor with superconducting leads and a normal-metal island can be refrigerated by an alternating voltage applied to the gate electrode. The simultaneous measurement of the dc…