English
Related papers

Related papers: Complex Impedance as a Diagnostic Tool for Charact…

200 papers

We theoretically investigate the temperature-to-phase conversion (TPC) process occurring in dc superconducting quantum interferometers based on superconductor--normal metal--superconductor (SNS) mesoscopic Josephson junctions. In…

Superconductivity · Physics 2018-05-21 P. Virtanen , A. Ronzani , F. Giazotto

The responsivity and noise of a voltage-biased superconducting transition-edge sensor depends strongly on the details of its thermal model, and the simplest theory for TES response assumes a single heat capacity connected to the heat bath.…

Superconductivity · Physics 2012-10-26 Ilari J. Maasilta

We have developed a completely lithographic antenna-coupled bolometer for CMB polarimetry. The necessary components of a millimeter wave radiometer -- a beam forming element, a band defining filter, and the TES detectors -- are fabricated…

The next generation of bolometric experiments searching for rave events, in particular for the neutrino-less double beta decay, needs fast, high-sensitivity and easy-to-scale cryogenic light detectors. The CALDER project (2014-2020)…

Since the invention of the bolometer, its main design principles relied on efficient light absorption into a low-heat-capacity material and its exceptional thermal isolation from the environment. While the reduced thermal coupling to its…

Mesoscale and Nanoscale Physics · Physics 2018-09-26 D. K. Efetov , R. -J. Shiue , Y. Gao , B. Skinner , E. Walsh , H. Choi , J. Zheng , C. Tan , G. Grosso , C. Peng , J. Hone , K. C. Fong , D. Englund

Industry 4.0 drives the demand for cost-efficient and reliable process data and condition monitoring. Therefore, visualizing the state of tribological contacts becomes important, as they are regularly found in the center of many…

Signal Processing · Electrical Eng. & Systems 2024-11-07 Steffen Puchtler , Julius van der Kuip , Florian Michael Becker-Dombrowsky , Eckhard Kirchner

We demonstrate the capabilities of a high temperature measurement set-up recently developed at our institute. It is dedicated to the characterization of semiconductor devices and test structures in the temperature range from room…

General Physics · Physics 2008-01-08 P. Borthen , G. Wachutka

The paper describes the realization process of the high frequency power standard based on a twin broadband microcalorimeter designed for effective efficiency measurement of coaxial power sensors with indirect heating thermocouples. The…

Instrumentation and Detectors · Physics 2021-03-09 Emil Vremera , Luciano Brunetti , Luca Oberto , Marco Sellone

Transition-edge sensors (TESs) are used as very sensitive thermometers in microcalorimeters aimed at detection of different wavelengths. In particular, for soft X-ray astrophysics, science goals require very high resolution…

Instrumentation and Detectors · Physics 2021-02-19 E. Taralli , C. Pobes , P. Khosropanah , L. Fabrega , A. Camon , L. Gottardi , K. Nagayoshi , M. Ridder , M. Bruijn , J. R. Gao

This paper presents a study of accuracy issues in thermal modeling of high power LED modules on system level. Both physical as well as numerical accuracy issues are addressed. Incorrect physical assumptions may result in seemingly correct,…

Materials Science · Physics 2007-09-13 D. Benoy

The next generation of ultra-low-noise cryogenic detectors for space science applications require continued exploration of materials characteristics at low temperatures. The low noise and good energy sensitivity of current Transition Edge…

Mesoscale and Nanoscale Physics · Physics 2011-02-01 D. J. Goldie , D. M. Glowacka , K. Rostem† , S. Withington

We describe the design, construction, calibration, and operation of a relatively simple differential capacitive dilatometer suitable for measurements of thermal expansion and magnetostriction from 300 K to below 1 K with a low-temperature…

Capacitance measurement is a useful technique in studying quantum devices, as it directly probes the local particle charging properties, i.e. the system compressibility. Here we report one approach which can measure capacitance from mK to…

Mesoscale and Nanoscale Physics · Physics 2022-12-29 Lili Zhao , Wenlu Lin , Xing Fan , Yuanjun Song , Hong Lu , Yang Liu

The CALICE collaboration is developing an engineering prototype of an analog hadron calorimeter for a future linear collider detector. The prototype has to prove the feasibility of building a realistic detector with fully integrated…

Instrumentation and Detectors · Physics 2019-08-13 Oskar Hartbrich , Mark Terwort

We have measured the interlayer thermal conductivity of crystals of the organic semiconductor rubrene, using ac-calorimetry. Since ac-calorimetry is most commonly used for measurements of the heat capacity, we include a discussion of its…

Materials Science · Physics 2015-06-15 H. Zhang , J. W. Brill

The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated…

Instrumentation and Detectors · Physics 2022-11-24 Ivan Smiljanic , Ivanka Bozovic Jelisavcic , Goran Kacarevic , Natasa Vukasinovic , Ivana Vidakovic , Vladimir Rekovic

We present a scheme and demonstrate measurements of a Coulomb blockade thermometer (CBT) in a microwave transmission setup. The sensor is embedded in an $LCR$ resonator, where $R$ is determined by the conductance of the junction array of…

Mesoscale and Nanoscale Physics · Physics 2021-11-30 Florian Blanchet , Yu-Cheng Chang , Bayan Karimi , Joonas T. Peltonen , Jukka P. Pekola

Hidden defects affecting the interface in a composite slab are evaluated from thermal data collected on the upper side of the specimen. First we restrict the problem to the upper component of the object. Then we investigate heat transfer…

Applied Physics · Physics 2019-10-11 Gabriele Inglese , Roberto Olmi

We report a study of the complex AC impedance of CVD grown graphene. We measure the explicit frequency dependence of the complex impedance and conductance over the microwave and terahertz range of frequencies using our recently developed…

Materials Science · Physics 2015-05-28 W. Liu , R. Valdés Aguilar , Y. Hao , R. S. Ruoff , N. P. Armitage

Bolometers are cryogenic calorimeters which feature excellent energy resolution, low energy threshold, high detection efficiency, flexibility in choice of materials, particle identification capability if operated as hybrid devices. After…

Instrumentation and Detectors · Physics 2018-04-04 Fabio Bellini
‹ Prev 1 4 5 6 7 8 10 Next ›