Related papers: Booster Synchrotron Frequency Below Transition
The kinetic energy of an atom recoiling due to absorption of a photon was measured as a frequency using an interferometric technique called ``contrast interferometry''. Optical standing wave pulses were used as atom-optical elements to…
The Shanghai Synchrotron Radiation Facility (SSRF) contains a 3.5-GeV storage ring serving as a national X-ray synchrotron radiation user facility characterized by a low emittance and a low coupling. The stability and quality of the…
Partial discharge (PD) incidents can occur in critical components of high-speed rail electric systems, such as transformers and switchgears, due to localized insulation defects that cannot withstand electric stress, leading to potential…
An asynchronous accelerator is described, in which the principle of its operation permits the active longitudinal bunch compression of accelerated proton beams, to overcome the space charge limitation effects of intense bunches. It is shown…
Autocorrelation of electromagnetic fields emitted by high-power microwave sources makes it possible to determine the phase diffusion coefficient $D$. The value of $D$ imposes significant constraints on synchronization of several HPM…
Weak transitions in the (2,0) overtone band of the HD molecule at $\lambda = 1.38 \, \mu$m were measured in saturated absorption using the technique of noise-immune cavity-enhanced optical heterodyne molecular spectroscopy. Narrow…
Slow extraction of beam from synchrotrons or storage rings as required by many fixed target experiments is performed by controlled excitation and feeding of a structural lattice resonance. Due to the sensitive nature of this resonant…
We present the design, fabrication and measured performance of a hierarchical sinuous-antenna phased array coupled to transition-edge-sensor (TES) bolometers for measurements of the cosmic microwave background (CMB). To efficiently cover a…
A multispeckle technique for efficiently measuring correctly ensemble-averaged intensity autocorrelation functions of scattered light from non-ergodic and/or non-stationary systems is described. The method employs a CCD camera as a…
We describe a technique for mapping the spatial variation of static electric, static magnetic, and rf magnetic fields using a pulsed atomic or molecular beam. The method is demonstrated using a beam designed to measure the electric dipole…
Spectral Doppler ultrasound imaging allows visualizing blood flow by estimating its velocity distribution over time. Duplex ultrasound is a modality in which an ultrasound system is used for displaying simultaneously both B-mode images and…
An experimental scheme is introduced to measure multiple parameters that are encoded in the phase quadrature of a light beam. Using a modal description and a spectrally-resolved homodyne detection, it is shown that all of the information is…
The recent introduction of coherent optical communications has created a compelling need for ultra-fast phase-sensitive measurement techniques operating at milliwatt peak power levels and in time scales ranging from sub-picoseconds to…
Heart and respiration rate measurement using Doppler radar is a non-contact and non-obstructive way for remote thorough-clothing monitoring of vital signs. The modulated back-scattered radar signal in the presence of high noise and…
Synchronization is a fundamental phenomenon in dynamical systems, occurring in a wide range of contexts such as mechanical, chemical, biological, and social systems. In this work, we explore a novel manifestation of synchronization in…
A number of modern millimeter, sub-millimeter, and far-infrared detectors are read out using superconducting microwave (1-10GHz) resonators. The main detector technologies are Transition Edge Sensors, read out using Microwave SQUID…
Using coherent phase states, parameterized phase state distributions for a single-mode radiation field are introduced and their integral relation to the phase-parameterized field-strength distributions is studied. The integral kernel is…
For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer…
Vibration-based condition monitoring techniques are commonly used to detect and diagnose failures of rolling bearings. Accuracy and delay in detecting and diagnosing different types of failures are the main performance measures in condition…
The demand from industry to produce accurate acceleration measurements down to ever lower frequencies and with ever lower noise is increasing. Different vibration transducers are used today for many different purposes within this area, like…