Related papers: Optimization and performance of an optical cardio-…
The design and operation of a homemade low cost vibrating sample magnetometer is described here. The sensitivity of this instrument is better than 10-2 emu and found to be very efficient for the measurement of magnetization of most of the…
Optically pumped magnetometers (OPMs) are revolutionising the task of magnetic-field sensing due to their extremely high sensitivity combined with technological improvements in miniaturisation which have led to compact and portable devices.…
We introduce a wide-field magneto-optical microscope to probe magnetization dynamics with femtosecond temporal and sub-micrometer spatial resolution. We carefully calibrate the non-linear dependency between the magnetization of the sample…
We propose to use an optical cavity to enhance the sensitivity of magnetometers relying on the detection of the spin state of high-density nitrogen-vacancy ensembles in diamond using infrared optical absorption. The role of the cavity is to…
This review article discusses current technological advances in biomedical devices,emphasizing cardiovascular and ophthalmic application diagnostic,monitoring, and prosthetic instruments and systems. The scope encompasses various aspects,…
In this paper, we presented the design and development of a new integrated device for measuring heart rate using fingertip to improve estimating the heart rate. As heart related diseases are increasing day by day, the need for an accurate…
We have demonstrated a remote magnetometer based on sodium atoms in the Earth's mesosphere, at a 106-kilometer distance from our instrument. A 1.33-watt laser illuminated the atoms, and the magnetic field was inferred from back-scattered…
Objective- Heart rate monitoring using wrist type Photoplethysmographic (PPG) signals is getting popularity because of construction simplicity and low cost of wearable devices. The task becomes very difficult due to the presence of various…
In this work we propose, and experimentally demonstrate, the use of a self-oscillating all-optical atomic magnetometer for magnetic induction measurements. Given the potential for miniaturization of atomic magnetometers, and their extreme…
Optically pumped magnetometers are ultra-sensitive devices, but this sensitivity can significantly degrade due to heading errors, whereby a change in the angle between the pumping laser and the magnetic field translates to a change in the…
We demonstrate a pump-probe strobe light spectroscopy for sensitive detection of magneto-optical dynamics in the context of hybrid magnonics. The technique uses a combinatorial microwave-optical pump-probe scheme, leveraging both the…
Nitrogen-vacancy (N-V) center in diamond provides a robust, solid-state platform for magnetic field measurements at room temperature. To harness its potential in inspecting inaccessible regions, here we present a compact endoscopic…
A multi-channel atomic magnetometer operating in an unshielded environment is described and characterised. The magnetometer is based on D1 optical pumping and D2 polarimetry of Cs vapour contained in gas-buffered cells. Several technical…
Diamond defect centers are promising solid state magnetometers. Single centers allow for high spatial resolution field imaging but are limited in their magnetic field sensitivity to around 10 nT/Hz^(1/2) at room-temperature. Using defect…
Ensembles of nitrogen vacancy centres (NVCs) in diamond can be employed for sensitive magnetometry. In this work we present a fiber-coupled NVC magnetometer with an unshielded sensitivity of (30 $\pm$ 10) pT/$\sqrt{\textrm{Hz}}$ in a (10 -…
We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed $^{87}$Rb scalar atomic magnetometer. This approach enables simultaneous measurements of the total magnetic field and its two polar…
We propose and demonstrate a radio-frequency atomic magnetometer with sub-Doppler laser cooled rubidium-87. With a simple and compact design, our system demonstrates a sensitivity of $330~pT/\sqrt{Hz}$ in an unshielded environment, thus…
Scalar optically-pumped magnetometers (OPMs) are being developed in small packages with high sensitivities. The high common-mode rejection ratio of these sensors allows for detection of very small signals in the presence of large background…
Damage in infrastructure is often hidden until it becomes costly or dangerous. Common examples include corrosion under insulation, early fatigue damage in steel, corrosion of embedded reinforcement, and abnormal current flow in batteries…
We carry out an experimental feasibility study of a magnetic field sensor based on the kinetic inductance of the high-$T_\mathrm{c}$ superconductor yttrium barium copper oxide. We pattern thin superconducting films into radio-frequency…