Related papers: Modelling and Measurement of Charge Transfer in Mu…
We report on measurements of charge transfer in GEM structures in high magnetic fields. These were performed in the framework of the R&D work for a Time Projection Chamber at a future Linear Collider. A small test chamber has been installed…
We have developed a gating foil for the time projection chamber envisaged as a central tracker for the international linear collider experiment. It has a structure similar to the Gas Electron Multiplier (GEM) with a higher optical aperture…
The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future…
In this paper, a detailed investigation has been carried out to understand the physics behind GEM charging-up and its effects on gain. Experiments have been performed on both double and triple GEM with the help of 55Fe X-ray source and a…
GEM are widely used as amplification stages in gaseous detectors exposed to high rates. The GEM consists of a polyimide foil which is coated by two thin copper layers. Charges collected into the holes or created during the amplification…
The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future…
Gas electron multipliers (GEM) detectors are gaseous detectors widely used for tracking and imaging applications due to their good position resolution, high efficiency at high irradiation rates, among other factors. In the present work,…
Time Projection Chamber (TPC) has been chosen as the main tracking system in several high-flux and high repetition rate experiments. These include on-going experiments such as ALICE and future experiments such as PANDA at FAIR and ILC.…
A Time Projection Chamber (TPC) using micro-pattern gas detectors is planned as the main tracking device for a detector at the next Linear Collider. A novel support structure for Gas Electron Multipliers (GEMs), which minimizes the material…
The Gas Electron Multiplier (GEM) detectors are widely used in high-energy physics (HEP) experiments as tracking devices because of their excellent position resolution and to handle high particle rates capability. Charging-up effect is a…
Gas Electron Multipliers (GEM) are among the more prominent Micro-Pattern Gaseous Detectors (MPGDs) and widely used in high energy particle physics experiments and various related applications. Adoption of different production techniques…
Gas Electron Multiplier (GEM) is a cutting edge Micro Pattern Gaseous detector (MPGD) technology suitable as tracking device in high rate Heavy-Ion (HI) experiments for their good spatial resolution and most importantly high rate handling…
Systematic studies on the GEM foil material are performed to measure the moisture diffusion rate and saturation level. These studies are important because the presence of this compound inside the detector's foil can possibly change its…
The Gas Electron Multiplier (GEM) has become a widely used technology for high-rate particle physics experiments like COMPASS, LHCb and are being used as the readout system for the upcoming upgrade version of other experiments such as ALICE…
Characteristics of triple GEM detector have been studied systematically. The variation of the effective gain and energy resolution of GEM with variation of the applied voltage has been measured with Fe55 X-ray source for different gas…
Controlled etching of copper electrodes in Gas Electron Multiplier foils allows a reduction of the material budget by more than a factor of two for a triple-GEM detector. Detectors making use of thinned foils provide performances similar to…
A large volume time projection chamber (TPC) has been proposed as main tracking device for a detector at a future linear e+e- collider. Gas electron multipliers (GEMs) are studied as potential replacement of the conventional wire based gas…
Modern time projection chambers are increasingly based on micro pattern gas detector readout systems. In this paper a self-supporting method used to mount Gas Electron Multiplier foils is presented. It is based on light weight ceramic…
Gas Electron Multiplier (GEM) is one of the mostly used gaseous detectors in the High Energy Physics (HEP) experiments. GEMs are widely used as tracking devices due to their high-rate handling capability and good position resolution. An…
Systematic studies on the gain and the energy resolution have been carried out varying the voltage across the GEM foils for both single mask and double mask triple GEM detector prototypes. Variation of the gain and the energy resolution…