English
Related papers

Related papers: Position-Sensitive Detector with Depth-of-Interact…

200 papers

We present the model of an ultrasensitive mid-infrared (mid-IR) photodetector operating in the mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) domains consisting of a hybrid heterostructure made of nanopatterned graphene…

Mesoscale and Nanoscale Physics · Physics 2021-03-19 Muhammad Waqas Shabbir , Sayan Chandra , Michael N. Leuenberger

Point-like broadband ultrasound detection can significantly increase the resolution of ultrasonography and optoacoustic (photoacoustic) imaging, yet current ultrasound detectors cannot be miniaturised sufficiently. Piezoelectric transducers…

The aim of this paper is to fully characterize the new multi-anode photomultiplier tube R11265-103-M64, produced by Hamamatsu. Its high effective active area (77%), its pixel size, the low dark signal rate and the capability to detect…

Instrumentation and Detectors · Physics 2015-06-19 L. Cadamuro , M. Calvi , L. Cassina , A. Giachero , C. Gotti , B. Khanji , M. Maino , C. Matteuzzi , G. Pessina

The characteristics and performance of a Dual Position Sensitive Multi-Wire Proportional Counter (DPS-MWPC) used to measure the scattering angle, interaction position on the target and the velocity of reaction products, detected in the…

We measured the thickness of an insensitive surface layer of a PIN photodiode, Hamamatsu S3590-06, used in the Tokyo Axion Helioscope. We made alpha-particles impinge on the PIN photodiode in various incidence angles and measured the pulse…

Instrumentation and Detectors · Physics 2009-11-11 Y. Akimoto , Y. Inoue , M. Minowa

Objective: This paper introduces a novel PET imaging methodology called 3-dimensional positron imaging (3D{\pi}), which integrates total-body (TB) coverage, time-of-flight (TOF) technology, ultra-low dose imaging capabilities, and…

This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of…

Instrumentation and Detectors · Physics 2021-07-07 M. Jadhav , W. Armstrong , I. Cloet , S. Joosten , S. M. Mazza , J. Metcalfe , Z. -E. Meziani , H. F. -W. Sadrozinski , B. Schumm , A. Seiden

We report the results of the performance characterization of a prototype wavefront sensor for millimetric adaptive optics (MAO) installed on the Nobeyama 45 m radio telescope. MAO is a key component to realize a future large-aperture…

Instrumentation and Methods for Astrophysics · Physics 2022-07-18 Satoya Nakano , Yoichi Tamura , Akio Taniguchi , Sachiko Okumura , Ryohei Kawabe , Nozomi Okada , Tomoko Nakamura , Yuhei Fukasaku

Conventional silicon photomultipliers (SiPMs) are well established as light detectors with single-photon-detection capability and used throughout high energy physics, medical, and commercial applications. The possibility to produce single…

Silicon photomultiplier (SiPM), a new type of photosensor, is considered a substitute for traditional photomultiplier tube (PMT) in the next generation of dark matter and neutrino detectors, especially in noble gas detectors like liquid…

Instrumentation and Detectors · Physics 2023-05-31 T. A. Wang , C. Guo , X. H. Liang , L. Wang , M. Y. Guan , C. G. Yang , J. C. Liu , F. Y. Lin

In this paper, we present the design and preliminary performance evaluation of a new heavy-ion detector for direct measurements of heavy {\Lambda} hypernuclei lifetime. The detector employs the previously developed 10 picosecond resolution…

We demonstrate the capabilities of a highly parallel, active pixel detector for large-area, mass spectrometric imaging of biological tissue sections. A bare Timepix assembly (512x512 pixels) is combined with chevron microchannel plates on…

Instrumentation and Detectors · Physics 2013-05-24 Julia H. Jungmann , Donald F. Smith , Luke MacAleese , Ivo Klinkert , Jan Visser , Ron M. A. Heeren

We report on the construction of a UHV compatible 40 mm active diameter detector based on micro channel plates and assembled directly on the feed-throughs of a DN63CF flange. It is based on the charge division technique and uses a standard…

Instrumentation and Detectors · Physics 2016-01-20 S. Lupone , S. Damoy , A. Husseen , N. Briand , M. Debiossac , S. Tall , P. Roncin

The Probe for Luminosity Measurement detector is a novel luminometer designed to monitor the luminosity and beam conditions of the Large Hadron Collider at the interaction point of the LHCb experiment, starting from Run 3. The detector is…

Instrumentation and Detectors · Physics 2026-05-19 A. Bellavista , A. Carbone , V. Chaumat , F. Ferrari , T. Nguyen-Trung , V. Puill , L. Toscano , A. Villa

0.2 um fully-depleted SOI technology has been developed a for X-ray pixel detectors. To improve the detector performance, some advanced process technologies are developing continuously. To utilize the high resistivity FZ-SOI, slow ramp up…

Instrumentation and Detectors · Physics 2015-11-18 Masao Okihara , Hiroki Kasai , Noriyuki Miura , Naoya Kuriyama , Yoshiki Nagatomo

Purpose: To develop and evaluate DosimeTron, an agentic AI system for automated patient-specific MC internal radiation dosimetry in PET/CT examinations. Materials and Methods: In this retrospective study, DosimeTron was evaluated on a…

Medical Physics · Physics 2026-04-09 Eleftherios Tzanis , Michail E. Klontzas , Antonios Tzortzakakis

The Institute for Astronomy and Astrophysics in T\"ubingen (IAAT) has a long-term experience in developing and building space-qualified imaging and photon counting microchannel-plate (MCP) detectors, which are sensitive in the ultraviolet…

The angular coverage extension of the KLOE-2 electromagnetic calorimeter, from a polar angle of 20$^{\circ}$ down to $8^{\circ}$, will increase the multiphoton detection capability of the experiment enhancing the search reach for rare kaon,…

Instrumentation and Detectors · Physics 2010-05-27 M. Cordelli , F. Happacher , M. Martini , S. Miscetti , I. Sarra , M. Schioppa , S. Stucci , G. Xu

A new prototype of large area Multi-gap Resistive Plate Chamber (MRPC) with long readout strips was built. This Long-strip Multi-gap Resistive Plate Chamber (LMRPC) is double stacked and has ten 250 $\mu$m-thick gas gaps. Signals are read…

Instrumentation and Detectors · Physics 2015-05-20 Yongjie sun , Cheng Li , Zebo Tang , Lailin Xu , Tianxiang Chen , Ming Shao