Positron Emission Tomography (PET) using time-of-flight information, which can greatly improve the quality of the reconstructed image, has recently become an exciting topic. In this work, 3.2mm*3.2mm*25mm finger-like LYSO crystals were used…

Instrumentation and Detectors · Physics 2015-07-17 Liu Jun-Hui , Xu Jiong-Hui , Cheng Feng-Feng , Li Dao-Wu , Zhang Zhi-Ming , Wang Bao-Yi , Wei Long

The main challenges posed by the design of future Positron Emission Tomography machines are the improvement of the spatial and timing resolution and the combined operation with magnetic resonance. The Micro Pixel Photon Counter by Hamamatsu…

Medical Physics · Physics 2008-05-06 N. D'Ascenzo , E. Garutti , M. Goettlich , H. C. Schultz-Coulon , A. Tadday

Presice measurements of the photons conversion points in the scintillators are required to achieve a high spatial resolution of the PET system. I have developed a new method of reconstruction of the depth-of-interaction information for PET…

Instrumentation and Detectors · Physics 2018-05-18 Andrei Yu. Semenov

A 3-D position sensitive neutron detector is being developed based on a plastic scintillator array. A double side SiPM readout is used to determine the depth of interaction (DOI) in each scintillator unit. In the preliminary test, the DOI…

Instrumentation and Detectors · Physics 2019-07-11 Yang Tian , Yidong Fu , Yulan Li , Yuanjing Li

Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…

Instrumentation and Detectors · Physics 2022-11-17 Florian Mueller , Stephan Naunheim , Yannick Kuhl , David Schug , Torsten Solf , Volkmar Schulz

We report on the measurements performed using a 22Na source on a detector element for an MRI-compatible TOF-PET endorectal prostate probe, with Depth-Of-Interaction sensitivity. It is made from a LYSO scintillator crystal, wrapped with…

Instrumentation and Detectors · Physics 2015-06-11 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO)…

Instrumentation and Detectors · Physics 2024-06-28 A. Galindo-Tellez , V. Sharyy , C. -H. Sung , M. Follin , L. Cappellugola , S. Curtoni , M. Dupont , C. Morel , D. Breton , J. Maalmi , D. Yvon

Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and…

Instrumentation and Detectors · Physics 2019-09-19 J. M. C. Brown , S. E. Brunner , D. R. Schaart

Objective. This study investigates the best achievable performance of a brain-dedicated PET system with high resolution and sensitivity by evaluating different detector configurations, while maintaining a practical system design suitable…

Medical Physics · Physics 2026-02-26 Yuemeng Feng , Lisa Blackberg , Arkadiusz Sitek , Hamid Sabet

We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative…

Instrumentation and Detectors · Physics 2021-04-08 L. Bläckberg , S. Sajedi , G. El Fakhri , H. Sabet

Depth-of-interaction (DOI) encoding is an effective strategy for reducing parallax error and preserving spatial resolution in positron emission tomography (PET), particularly in compact small-animal scanners. To enable efficient…

Medical Physics · Physics 2026-03-10 Satzhan Sitmukhambetov , Junwei Du , Mingwu Jin , Yujie Chi

Small animal Positron Emission Tomography (PET) is dedicated to small animal imaging, which requires high position and energy precision, as well as good flexibility and efficiency of the electronics. This paper presents the design of a…

Instrumentation and Detectors · Physics 2019-09-27 Jiaming Lu , Lei Zhao , Kairen Chen , Peipei Deng , Bowen Li , Shubin Liu , Qi An

We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…

Instrumentation and Detectors · Physics 2018-05-30 Sylvain Lupone , Pierre Soulisse , Philippe Roncin

Objective: Image reconstruction in high resolution PET scanners with depth of interaction (DOI) capability is computationally challenging due to the high sampling in detector and image space. This study evaluates the use of a virtual…

Preclinical research and organ-dedicated applications require high-resolution positron emission tomography (PET) detectors to visualize small structures and understand biological processes at a finer level of detail. Current commercial…

This work summarizes the design, construction, initial performance evaluation and pilot clinical results of the IMAS system, a long axial field of view (FOV), also known as total-body (TB-), positron emission tomography (PET) prototype…

Position sensitive detectors (PSDs) offer possibility to track single active marker's two (or three) degrees of freedom (DoF) position with a high accuracy, while having a fast response time with high update frequency and low latency, all…

Robotics · Computer Science 2022-01-12 Young-Ho Kim , Ankur Kapoor , Tommaso Mansi , Ali Kamen

A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…

Instrumentation and Detectors · Physics 2015-06-03 L. Gruber , G. S. M. Ahmed , S. E. Brunner , P. Bühler , J. Marton , K. Suzuki

The TT-PET collaboration is developing a small animal TOF-PET scanner based on silicon detectors featuring 30 ps RMS time resolution and intended to be inserted in an existing MRI scanner. The TT-PET scanner makes use of a stack of layers…

This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration…