A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…

Instrumentation and Detectors · Physics 2017-09-20 B. B. Wiggins , Varinderjit Singh , J. Vadas , J. Huston , T. K. Steinbach , S. Hudan , R. T. deSouza

Compact X-rays detectors made of 1/2" or 1" :LaBr3:Ce crystals of cubic shape with SiPM array readout have been developed for the FAMU experiment at RIKEN-RAL. The aim is a precise measurement of the proton Zemach radius with incoming…

Instrumentation and Detectors · Physics 2022-11-10 M. Bonesini , R. Benocci , R. Bertoni , A. Menegolli , M. Prata , M. Rossella , R. Rossini

The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved…

Multiwire and microstrip porous detectors have been developed and investigated for DC operation. The multiwire porous detector consists of anode wires, an Al cathode and a gap between them filled with porous CsI. The microstrip porous…

Instrumentation and Detectors · Physics 2007-05-23 M. P. Lorikyan

This study demonstrates the feasibility of a novel fabrication technique for high spatial resolution CsI: Tl scintillation detectors tailored for single photon emission computed tomography (SPECT) systems. Building upon our previously…

Medical Physics · Physics 2026-02-16 Xi Zhang , Arkadiusz Sitek , Lisa Blackberg , Matthew Kupinski , Lars Furenlid , Hamid Sabet

Hyperion-IID is a positron emission tomography (PET) insert which allows simultaneous operation in a clinical magnetic resonance imaging (MRI) scanner. To read out the scintillation light of the employed LYSO crystal arrays with a pitch of…

A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at…

A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs…

Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…

Instrumentation and Detectors · Physics 2025-02-12 Shiv K. Subedi , Simon R. Cherry , Yi Qiang , Peng Peng

A new, inexpensive polarimetric unit has been constructed for the Dominion Astrophysical Observatory (DAO) 1.8-m Plaskett telescope. It is implemented as a plug-in module for the telescope's existing Cassegrain spectrograph, and enables…

Instrumentation and Methods for Astrophysics · Physics 2015-06-04 D. Monin , D. Bohlender , T. Hardy , L. Saddlemyer , M. Fletcher

Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$…

The planned luminosity increase at the Large Hadron Collider in the coming years has triggered interest in the use of the particles' time of arrival as additional information in specialized detectors to mitigate the impact of pile-up. The…

We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing…

Instrumentation and Detectors · Physics 2009-11-13 O. Jagutzki , V. Dangendorf , R. Lauck , A. Czasch , J. Milnes

Associated Particle Imaging (API) is a nuclear technique that allows for the nondestructive determination of 3D isotopic distributions. The technique is based on the detection of the alpha particles associated with the neutron emitted in…

Instrumentation and Detectors · Physics 2018-11-22 Mauricio Ayllon Unzueta , Will Mixter , Zachary Croft , John Joseph , Bernhard Ludewigt , Arun Persaud

The Hamamatsu R12699-406-M2 is a $2\times2$ multi-anode 2-inch photomultiplier tube that offers a compact form factor, low intrinsic radioactivity, and high photocathode coverage. These characteristics make it a promising candidate for…

Instrumentation and Detectors · Physics 2025-12-02 M. Adrover , L. Baudis , A. Bismark , A. P. Colijn , J. J. Cuenca-García , M. P. Decowski , M. Flierman , T. den Hollander

The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$)…

The aim of this work is to show the potential capabilities of monolithic crystals coupled to large SiPM arrays, to be considered as detector blocks for PET scanners enabling Time Of Flight (TOF) capabilities. Monolithic blocks allow one to…

We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects,…

Micro-channel plate (MCP)-based photodetectors are capable of picosecond level time resolution and sub-mm level position resolution, which makes them a perfect candidate for the next generation large area photodetectors. The large-area…

Instrumentation and Detectors · Physics 2016-04-27 Jingbo Wang , Karen Byrum , Marcel Demarteau , Jeffrey Elam , Anil Mane , Edward May , Robert Wagner , Dean Walters , Junqi Xie , Lei Xia , Huyue Zhao

Total-Body PET (TB-PET) scanners represent a significant advancement in medical diagnostics, exemplified by the uEXPLORER, the world's first TB-PET system with an axial span of 194 cm, which exhibits exceptional sensitivity and spatial…

Instrumentation and Detectors · Physics 2025-04-10 D. Choudhary , S. Nag