English
Related papers

Related papers: Impedance Measurement Setup for Higher-Order Mode …

200 papers

The wire method is a more rapid and less costly method to measure impedances of RF components compared to methods using a beam. A setup using a single displaced wire to excite and measure transverse resonant modes in accelerating structures…

Accelerator Physics · Physics 2008-11-26 N. Baboi , G. B. Bowden , R. M. Jones , S. G. Tantawi , J. R. Lewandowski

Dipole wakefields in NLC (Next Linear Collider) structures have been measured with ASSET [1] and well predicted by a circuit model [2]. However, the experimental technique is both time-consuming and expensive. Here, we report on kick factor…

Accelerator Physics · Physics 2007-05-23 R. M. Jones , N. Baboi , N. M. Kroll

The coaxial wire method provides an experimental way of measuring wake fields without the need for a particle beam. A special setup has been designed and is in the process of being fabricated at SLAC to measure the loss factors and…

Accelerator Physics · Physics 2007-05-23 N. Baboi , R. M. Jones , G. B. Bowden , V. Dolgashev , S. G. Tantawi , J. W. Wang

Both longitudinal and transverse coupling impedance for some critical components need to be measured for accelerator design. The twin wires method is widely used to measure longitudinal and transverse impedance on the bench. A mode error is…

Accelerator Physics · Physics 2014-10-14 Huang Liang-Sheng , Yoshiro Irie , Liu Yu-Dong , Wang Sheng

The injector linacs of the JLC/NLC project include the prelinac, the e+ drive linac, the $e- booster, and the $e+ booster. The first three will be S-band machines, the last one, an L-band machine. We have demonstrated that by using detuning…

Accelerator Physics · Physics 2007-05-23 Karl L. F. Bane , Zenghai Li

An electron/positron linear collider with a center-of-mass energy between 0.5 and 1 TeV would be an important complement to the physics program of the LHC in the next decade. The Next Linear Collider (NLC) is being designed by a US…

Accelerator Physics · Physics 2009-11-06 T. O. Raubenheimer

The injector linacs of the JLC/NLC comprise the e+ booster, the e- drive linac, the e+ booster, and the two prelinacs. These four systems together transport the two types of beams from the 80 MeV point at the end of their respective…

Accelerator Physics · Physics 2007-05-23 K. L. F. Bane , Z. Li

Coaxial wire measurements have provided a simple and effective way to measure the beam coupling impedance of accelerator structures for a number of years. It has been known how to measure the longitudinal and dipolar transverse impedance…

Accelerator Physics · Physics 2011-10-11 Hugo Day , Fritz Caspers , Elias Metral , Roger Jones

In the NLC (Next Linear Collider) small misalignments in each of the individual accelerator structures (or the accelerator cells) will give rise to wakefields which kick the beam from its electrical axis. This wakefield can cause BBU (Beam…

Accelerator Physics · Physics 2009-03-12 R. M. Jones , N. M. Kroll , R. H. Miller , T. O. Raubenheimer , G. V. Stupakov

The coaxial wire method is a common and appreciated technique to assess the beam coupling impedance of an accelerator element from scattering parameters. Nevertheless, the results obtained from wire measurements could be inaccurate due to…

Accelerator Physics · Physics 2024-06-17 Antuono Chiara , Zannini Carlo , Mostacci Andrea , Migliorati Mauro

Following successful design and fabrication of damped detuned structures, the R&D for the accelerating structures of the NLC/JLC linear collider project proceeded to studies of Rounded Damped Detuned Structure with curved cross section of…

High Energy Physics - Experiment · Physics 2007-05-23 T. Higo , Y. Funahashi , Y. Higashi , N. Hitomi , T. Suzuki , K. Takata , T. Takatomi , N. Toge , Y. Watanabe , Z. Li , R. H. Miller , J. W. Wang

A method is presented for characterizing the emittance dilution and dynamic aperture for an arbitrary closed lattice that includes guide field magnet errors, multipole errors and misalignments. This method, developed and tested at the…

Accelerator Physics · Physics 2015-06-17 James Shanks , Dave Rubin , David Sagan

The fast extraction kicker system is one of the most important accelerator components, whose inner structure will be the main source of the impedance in the RCS. It is necessary to understand the kicker impedance before its installation…

Accelerator Physics · Physics 2016-08-03 Liangsheng Huang , Sheng Wang , Yudong Liu , Yong Li , Renhong Liu , Ouzheng Xiao

This paper describes a comprehensive experimental study on viability and prospects for the measurement of electroweak observables in $e^{+}e^{-}\rightarrow b\bar{b}$ and $e^{+}e^{-}\rightarrow c\bar{c}$ processes at the International Linear…

High Energy Physics - Experiment · Physics 2023-12-20 A. Irles , R. Pöschl , F. Richard

The single stretched-wire method is commonly used to measure the magnetic field strength and magnetic axis in an accelerator magnet. The integrated voltage at the connection terminals of the wire is a measure for the flux linked with the…

Accelerator Physics · Physics 2020-06-18 Stephan Russenschuck

Speed is a major concern for high density VLSI networks. In this paper the closed form delay model for current mode signalling in VLSI interconnects has been proposed with resistive load termination. RLC interconnect line is modelled using…

Emerging Technologies · Computer Science 2014-12-30 Sunil Jadav , Munish Vashistah , Rajeevan Chandel

Recent experiments at SLAC [1,2] and CERN [3] have revealed evidence of significant deformation in the form of "pitting" of the cells of the 1.8m series of structures DDS/RDDS (Damped Detuned Structure/Rounded Damped Detuned Structure).…

Accelerator Physics · Physics 2008-11-26 R. M. Jones , N. M. Kroll , T. Higo , Z. Li , R. H. Miller , T. O. Raubenheimer , J. W. Wang

This paper outlines the RF design of the CLIC (Compact Linear Collider) 30 GHz main linac accelerating structure and gives the resulting longitudinal and transverse mode properties. The critical requirement for multibunch operation, that…

Accelerator Physics · Physics 2008-11-26 I. Wilson , W. Wuensch