English
Related papers

Related papers: Low-Energy Electron-Beam Diagnostics Based on the …

200 papers

We propose to use the near-threshold electron scattering data for atoms to guide the reliable experimental determination of their electron affinities (EAs), extracted using the Wigner Threshold Law, from laser photodetachment threshold…

Atomic Physics · Physics 2014-03-05 Zineb Felfli , Alfred Z. Msezane

The polarization and orbital angular momentum properties of light are of great importance in optical science and technology in the fields of high precision optical measurements and high capacity and high speed optical communications. Here…

The redshifted 21cm signal of neutral hydrogen from the epoch of reionization (EoR) is extremely weak and its first detection is therefore expected to be statistical with first-generation low-frequency radio interferometers. In this letter…

Cosmology and Nongalactic Astrophysics · Physics 2015-06-11 Qian Zheng , Xiang-ping Wu , Jun-hua Gu , Jingying Wang , Haiguang Xu

The traditional Thomson scattering diagnostic is based on measurement of the wavelength spectrum of scattered light, where electron temperature measurements are inferred from thermal broadening of the scattered laser light. At sufficiently…

Plasma Physics · Physics 2015-06-17 E. Parke , V. V. Mirnov , D. J. Den Hartog

The ELISE test facility at IPP Garching hosts a RF H-/D- ion source and an acceleration system. Its target is to demonstrate the performance foreseen for the ITER NBI system in terms of extracted current density (H/D), fraction of…

Plasma Physics · Physics 2022-11-08 M. Barbisan , F. Bonomo , U. Fantz , D. Wünderlich

The coherent reflectivity of a dense, relativistic, ultra-thin electron layer is derived analytically for an obliquely incident probe beam. Results are obtained by two-fold Lorentz transformation. For the analytical treatment, a plane…

Plasma Physics · Physics 2009-11-13 Hui-Chun Wu , Jürgen Meyer-ter-Vehn

Optical transition-edge sensors have shown energy resolution for resolving the number of incident photons at the telecommunication wavelength. Higher energy resolution is required for biological imaging and microscope spectroscopy. In this…

Instrumentation and Detectors · Physics 2022-07-27 Kaori Hattori , Toshio Konno , Yoshitaka Miura , Sachiko Takasu , Daiji Fukuda

We propose a method based on optically detected magnetic resonance (ODMR) to measure the decoherence time $T_{2}$ of a single electron spin in a semiconductor quantum dot. The electron spin resonance (ESR) of a single excess electron on a…

Mesoscale and Nanoscale Physics · Physics 2007-05-23 Oliver Gywat , Hans-Andreas Engel , Daniel Loss , R. J. Epstein , F. M. Mendoza , D. D. Awschalom

We study the electron-impact induced ionization of O$_{2}$ from threshold to 120 eV using the electron spectroscopy method. Our approach is simple in concept and embodies the ion source with a collision chamber and a mass spectrometer with…

Atomic Physics · Physics 2021-04-23 R. A. Lomsadze , M. R. Gochitashvili , R. Ya. Kezerashvili , M. Schulz

If the weak equivalence principle (WEP) is broken, the measured values of the parametrized post-Newtonian parameter $\gamma$ from photons with left- and right-handed circular polarizations should differ slightly, leading to the arrival-time…

High Energy Astrophysical Phenomena · Physics 2019-05-27 Jun-Jie Wei , Xue-Feng Wu

Electron microscopy prevalently uses energy-dispersive x-ray spectroscopy (EDS) and electron energy loss spectroscopy (EELS) for elemental analysis. EDS and EELS energy resolutions are commonly between 30-100 eV or 0.01-1 eV, respectively.…

Electrical Impedance Tomography (EIT) is a non-invasive imaging modality that has earned significant attention for its potential in real-time monitoring of various physiological parameters. Despite its promise, the sensitivity and…

Medical Physics · Physics 2024-06-06 Georgii Kormakov , Nikolay Koshev

A design of an efficient monochromatic electron source for Inverse Photoemission Spectroscopy (IPES) apparatus is described. The electron source consists of a BaO cathode, a focus electrostatic lens, a hemispherical deflection monochromator…

Instrumentation and Detectors · Physics 2014-01-13 Geng Dongping , Yang Yingguo , Liu Shuhu , Hong Caihao , Gao Xingyu

Transport of fast electron in overdense plasmas is of key importance in high energy density physics. However, it is challenging to diagnose the fast electron transport in experiments. In this article, we study coherent transition radiation…

Positron Emission Tomography (PET) is a medical imaging modality that utilizes positron-emitting isotopes, such as Ga-68 and F-18, for many diagnostic purposes. The positron annihilates with an electron from the surrounding area, creating…

Recent studies of secondary electron (SE) emission in scanning transmission electron microscopes suggest that material's properties such as electrical conductivity, connectivity, and work function can be probed with atomic scale resolution…

Materials Science · Physics 2023-11-01 Ondrej Dyck , Jawaher Almutlaq , Jacob L. Swett , Andrew R. Lupini , Dirk Englund , Stephen Jesse

We present a method of testing for the presence of energy dependent dispersion in transient features of a light curve. It is based on minimising the Kolmogorov distance between two cumulative event distribution functions. The unbinned and…

Instrumentation and Methods for Astrophysics · Physics 2015-06-11 Michael Daniel , Ulisses Barres de Almeida

A new method for measuring the electron temperature of the plasma in GOL-NB facility is proposed. The proposed method is based on measuring the ratio of intensities of spectral lines emitted by fast atoms injected into the plasma. The beams…

Plasma Physics · Physics 2023-07-31 S. Polosatkin

The International Linear Collider (ILC) is a future electron/positron collider at the energy frontier. Its physics goals are clearly focused on precision measurements at the electroweak scale and beyond. Beam energy and beam polarisation…

Instrumentation and Detectors · Physics 2015-06-22 Benedikt Vormwald

Multi-pass transmission electron microscopy (MPTEM) has been proposed as a way to reduce damage to radiation-sensitive materials. For the field of cryo-electron microscopy (cryo-EM), this would significantly reduce the number of projections…

‹ Prev 1 8 9 10 Next ›