English
Related papers

Related papers: Study of ion feedback in multi-GEM structures

200 papers

A thick gas electron multiplier (THGEM) chamber with an effective readout area of 10$\times$10 cm$^{2}$ and a 11.3 mm ionization gap has been tested along with two regular gas electron multiplier (GEM) chambers in a cosmic ray test system.…

Instrumentation and Detectors · Physics 2015-03-23 S. Yang , S. Das , B. Buck , C. Li , T. Ljubicic , R. Majka , M. Shao , N. Smirnov , G. Visser , Z. Xu , Y. Zhou

A general solution to the positive ion feedback problem in Hybrid Photon Detectors (HPD), photo multipliers (PM) and other similar detectors was found in the insertion of a permanent electrostatic potential barrier which prevents drift of…

Instrumentation and Detectors · Physics 2009-10-31 Daniel Ferenc , Dario Hrupec , Eckart Lorenz

Given their small mobility coefficient in liquid argon with respect to the electrons, the ions spend a considerably longer time in the active volume. We studied the effects of the positive ion current in a liquid argon time projection…

Instrumentation and Detectors · Physics 2018-05-09 R. Santorelli , S. di Luise , E. Sanchez Garcia , P. Garcia Abia , T. Lux , V. Pesudo , L. Romero

Gas-based time projection chambers (TPCs) have been shown to be highly sensitive X-ray polarimeters having excellent quantum efficiency while at the same time achieving large modulation factors. To observe polarization of the prompt X-ray…

Instrumentation and Methods for Astrophysics · Physics 2013-08-06 Z. Prieskorn , J. E. Hill , P. E. Kaaret , J. K. Black , K. Jahoda

A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under…

Instrumentation and Detectors · Physics 2016-12-26 Yu-Ning Zhang , Qian Liu , Hong-Bang Liu , Yi-Gang Xie , Xiao-Rui Lyu , Shi Chen , Wen-Qian Huang , Dao-Jin Hong , Yang-Heng Zheng

Air-ionization chambers have been used in radiotherapy and particle therapy for decades. However, fundamental parameters in action in the detector responses are sparsely studied. In this work we aimed to measure the electronic attachment,…

Instrumentation and Detectors · Physics 2016-09-14 Guillaume Boissonnat , Jean-Marc Fontbonne , Jean Colin , Aurelien Remadi , Samuel Salvador

The LCTPC collaboration is developing a time projection chamber (TPC) for a future linear collider. In the ILD concept for an ILC detector a TPC is foreseen as main tracking device. In order to get measurable signals on the anode, the…

Instrumentation and Detectors · Physics 2009-02-02 Lea Hallermann , Jeannine Beck

We describe a concept for a NASA SMEX Mission in which Gas Electron Multiplier (GEM) detectors, developed at CERN, are adapted for use in X-ray astronomy. These detectors can be used to obtain moderately large detector area and…

Based on a real-time measurement of the motion of a single ion in a Paul trap, we demonstrate its electro-mechanical cooling below the Doppler limit by homodyne feedback control (cold damping). The feedback cooling results are well…

We review latest progress in gaseous photomultipliers (GPM) combining solid photocathodes and various types of novel electron multipliers. Cascaded gaseous electron multipliers (GEM) coated with CsI photocathodes can efficiently replace…

Instrumentation and Detectors · Physics 2009-11-13 R. Chechik , A. Breskin

In this work we show the operation and results of an X-ray fluorescence imaging system using a cascade of three gas electron multipliers (GEM) and a pinhole assembly. The detector operates in Ar/CO$_2$ (90/10) at atmospheric pressure, with…

Instrumentation and Detectors · Physics 2019-06-26 Geovane G. A. de Souza , Hugo Natal da Luz

We present avalanche gain and associated resolution measurements recorded with a $^4$He:CO$_2$ (70:30) gas mixture and pure SF$_6$, a Negative Ion (NI) gas. SF$_6$ is of particular interest to the directional dark matter detection…

Instrumentation and Detectors · Physics 2022-06-22 T. N. Thorpe , S. E. Vahsen

The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector…

The Negative Ion Drift (NID) gas SF$_6$ has favourable properties for track reconstruction in directional Dark Matter (DM) searches utilising low pressure gaseous Time Projection Chambers (TPCs). However, the electronegative nature of the…

Instrumentation and Detectors · Physics 2023-11-20 A. G. McLean , N. J. C. Spooner , T. Crane , C. Eldridge , A. C. Ezeribe , R. R. Marcelo Gregorio , A. Scarff

The idea of implementing electroluminescence-based amplification through transparent multi-hole structures (FAT-GEMs) has been entertained for some time. Arguably, for such a technology to be attractive it should perform at least at a level…

We experimentally demonstrate dressed multi-wave mixing (MWM) and the reflection of the probe beam due to electromagnetically induced absorption (EIA) grating can coexist in a five-level atomic ensemble. The reflection is derived from the…

A high momentum resolution is required for the precision measurement of Higgs boson at the International Linear Collider (ILC) using the recoil mass technique. The International Large Detector (ILD) is designed to meet this requirement by…

Instrumentation and Detectors · Physics 2020-02-28 Yumi Aoki

Visual investigation of a Single Mask (SM) Gas Electron Multiplier (GEM) foil, showing small resistance~($\sim$ 40 k$\Omega$), is performed manually using an optical microscope. The GEM foil is scanned and the different imperfections in the…

Instrumentation and Detectors · Physics 2024-01-25 S. Chatterjee , A. Sen , S. Das , S. Biswas

The time-dependent gain variation of detectors incorporating Thick Gas Electron Multipliers (THGEM) electrodes was studied in the context of charging-up processes of the electrode's insulating surfaces. An experimental study was performed…

Instrumentation and Detectors · Physics 2018-03-28 M. Pitt , P. M. M. Correia , S. Bressler , A. E. C. Coimbra , D. Shaked Renous , C. D. R. Azevedo , J. F. C. A. Veloso , A. Breskin

Data from the Large Electron Positron collider (LEP) at CERN on hadron production in gamma-gamma interactions exceed the predictions of the standard model by an order of magnitude at the highest observed transverse momenta in three…

High Energy Physics - Phenomenology · Physics 2009-08-20 Philip Yock