Related papers: PLC Based Upgrades for the CAMD Linac and Storage …
We integrated an injector linac control system to the SPring-8 standard system on September 2000. As a result of this integration, the SPring-8 accelerator complex was controlled by one unified system. Because the linac was continuously…
As an accelerator control system survives over several years, it is often the case that new subsystems are introduced into the original control system. The control system for the KEK electron/positron injector-linac has been using Unix…
Most of the devices in the SLAC control system are accessed via interface modules in ~450 CAMAC crates. Low-cost controllers in these crates communicate via a SLAC-proprietary bit-serial protocol with 77 satellite control computers…
The LCLS began operations in 2009, utilizing SLAC's normal-conducting (NC) LINAC, which features control equipment dating back to the 1960s and 1980s. The Linac Electronics Modernization Plan (LEMP) aims to replace the legacy control…
We will use EPICS toolkit [1] to build a prototype for upgrading BEPC control system. The purposes are for the following three aspects: (1) Setup a network based distributed control system with EPICS. (2) Study some front-end control…
Implementation and commissioning of the EPICS based control system for the ISAC radioactive beam facility was completed. The target ion source, mass separator, and low-energy beam-lines started beam production for experiments. In parallel,…
The injection control system of Hefei Light Source (HLS) storage ring is a subsystem of the upgraded HLS control system, which is based upon EPICS. Three programmable logic controllers (PLCs) are used as device controllers, which control…
External contractors are developing the local cooling and vacuum control systems for the Spallation Neutron Source (SNS) linac. Soon these systems will be integrated into the facility-wide controls system. Allen-Bradley Logix5000 series…
The EPICS based control system of the ISAC radioactive beam facility supervises several sub-systems, which are controlled by PLCs. Most of the devices are protected by non-trivial interlocks, which are implemented with ladder-logic…
The Source Development Lab (SDL) at BNL consists of a 230 MeV electron linac and a 10 m long wiggler for short wavelength Free Electronic Laser (FEL) development. The original control system [1] was based on the one in use at the National…
A pipeline CAMAC controller with PC/104-Plus single board computer has been developed. The architecture of the pipeline CAMAC controller is completely different from that of traditional CAMAC controller. The pipeline CAMAC controller…
At the end of the Large Hadron Collider's Run 2, CERN's Proton Injector Linac 2, commissioned in 1978, delivered its final beam in December 2018. For Run 3, from March 2021, a new H$^{-}$ will take over the role: Linac4. The machine has…
The PEP-II storage rings at SLAC each have 3492 'buckets' into which electrons and positrons can be injected into the high- and low-energy rings. Equipment to measure the currents of all the individual buckets was originally provided by the…
Details on Final design for Cryogenic Electrical & Controls System for Fermilab' s next-gen particle accelerator PIP-II. Electrical Controls System includes instrumentation and controls of Cryogenics Distribution System and Cryomodules.…
The control system of the VEPP-4 facility was designed more than fifteen years ago and based on the home-developed CAMAC-embedded minicomputers Odrenok [1]. Five years ago, all computers were connected via Ethernet network. This step…
The Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory, a third-generation synchrotron light source operational since 1992, is undergoing a comprehensive upgrade of its storage ring RF control system. The legacy Horner PLC…
The linear accelerator (LINAC) at the Los Alamos Neu-tron Science Center (LANSCE) consists of Pre-buncher, Main-Buncher, low-energy beam transport (LEBT), four 201.25-MHz Drift Tube Linacs (DTLs) and forty-four 805-MHz Coupled Cavity Linacs…
KEKB completed all of the technical milestones, and had offered important insights into the flavor structure of elementary particles, especially the CP violation. The accelerator control system at KEKB and injector linac was initiated by a…
This report concerns the present status of VEPP-5 control system. The control system hardware consists of CAMAC blocks, a set of crate controllers based on INMOS transputers and ICL-1900 architecture processor Odrenok, and Pentium-based…
In this paper, a complete industrial validation of a recently published scheme for on-line adaptation of the control updating period in Model Predictive Control is proposed. The industrial process that serves in the validation is a…