English
Related papers

Related papers: Beam Diagnostics Systems For The National Ignition…

200 papers

We describe the design, operation, and first results of a photometric calibration project, called DICE (Direct Illumination Calibration Experiment), aiming at achieving precise instrumental calibration of optical telescopes. The heart of…

A Time of Flight monitoring system has been developed for BES3. The light source is a 442-443 nm laser diode, which is stable and provides a pulse width as narrow as 50 ps and a peak power as large as 2.6 W. Two optical-fiber bundles with a…

Instrumentation and Detectors · Physics 2008-11-26 F. A. Harris , J. W. Kennedy , Q. Liu , L. Nguyen , S. L. Olsen , M. Rosen , C. P. Shen , G. S. Varner , Y. K. Heng , Z. J. Sun , K. J. Zhu , Q. An , C. Q. Feng , S. B. Liu

The NIO1 experiment hosts a flexible RF H- ion source, developed by INFN-LNL and Consorzio RFX to improve the present concepts for the production and acceleration of negative ions. The source is also used to benchmark the instrumentation…

Plasma Physics · Physics 2022-11-09 M. Barbisan , B. Zaniol , M. Cavenago , G. Serianni , R. Pasqualotto

Visible-light long baseline interferometry holds the promise of advancing a number of important applications in fundamental astronomy, including the direct measurement of the angular diameters and oblateness of stars, and the direct…

The velocity of a ~3 GeV neutrino beam is measured by comparing detection times at the Near and Far detectors of the MINOS experiment, separated by 734 km. A total of 473 Far Detector neutrino events was used to measure (v-c)/c = 5.1 +/-…

High Energy Physics - Experiment · Physics 2008-11-26 MINOS Collaboration , P. Adamson

We demonstrate a narrow-linewidth 780 nm laser system with up to 40 W power and a frequency modulation bandwidth of 230 MHz. Efficient overlap on nonlinear optical elements combines two pairs of phase-locked frequency components into a…

In experimental nuclear physics (NP), high-precision electromagnetic calorimetry typically requires a good energy resolution and linear photosensor response on the level of (1-2)% over a full dynamic range of the detector. The beam of…

Instrumentation and Detectors · Physics 2025-10-22 Vladimir V. Berdnikov , Alexander Somov

We report the first measurement with no approximations of the full field of tightly focused vector beams (NA up to $1.23$) across areas of $\sim 9-49\,\lambda ^2$. Prior to focusing, the structured laser light has a linear or circular…

Optics · Physics 2021-07-20 Isael A. Herrera-Hernández , Pedro A. Quinto-Su

We describe an ultrafast time resolved pump-probe spectroscopy setup aimed at studying the switching of nanophotonic structures. Both fs pump and probe pulses can be independently tuned over broad frequency range between 3850 and 21050…

Optics · Physics 2010-11-02 Tijmen G. Euser , Philip J. Harding , Willem L. Vos

The NLC extraction line provides a secondary focal point with a low beta function and 2 cm dispersion which can be used for measurement of the beam energy spectrum. In this study, tracking simulations were performed to transport the 0.5 TeV…

Accelerator Physics · Physics 2008-11-26 Y. Nosochkov , T. O. Raubenheimer

An intense 146 MeV/c pion beam was stopped inside a scintillating fiber detector made out of 12 planes with 16 pixels each, where every pixel consists out of 8 times 8 scintillating fibers of 500 mkm diameter dense packed. The detector was…

Instrumentation and Detectors · Physics 2009-10-31 J. Baehr , R. Nahnhauer , S. Nerreter , R. Shanidze

Focused ion beams (FIBs) are widely used in nanofabrication for applications such as circuit repair, ultra-thin lamella preparation, strain engineering, and quantum device prototyping. Although the lateral spread of the ion beam is often…

Instrumentation and Detectors · Physics 2025-11-04 M. G. Masteghin , Z. P. Aslam , A. P. Brown , M. J. Whiting , S. K. Clowes , R. P. Webb , D. C. Cox

The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such…

Accelerator Physics · Physics 2018-03-06 R. Thurman-Keup , M. Alvarez , J. Fitzgerald , C. Lundberg , P. Prieto , J. Zagel , W. Blokland

To meet the stringent time calibration requirements for the Belle II experiment upgrade, particularly for its large-size KL and Muon Detector comprising tens of thousands of scintillator channels with time resolutions better than 100 ps, we…

Instrumentation and Detectors · Physics 2026-02-23 Ziyu Liu , Xiyang Wang , Shiming Zou , Xiaolong Wang , Junhao Yin , Minggang Zhao

A proton irradiation site for silicon detectors has been developed and commissioned at the Bonn Isochronous Cyclotron. The accelerator provides 14 MeV proton beams of up to 1 $\mu$A at beam widths of a few mm to the setup. Devices Under…

Instrumentation and Detectors · Physics 2024-05-07 Pascal Wolf , Dennis Sauerland , Reinhard Beck , Jochen Dingfelder

A laserwire transverse electron beam size measurement system has been developed and operated at the Accelerator Test Facility 2 (ATF2) at KEK. Special electron beam optics were developed to create an approximately 1 x 100 {\mu}m (vertical x…

Today's high-intensity laser facilities produce short pulses can, in tight focus, reach peak intensities of $10^{22}\,\mathrm{Wcm}^{-2}$ and, in long focus, wakefield-accelerate electrons to GeV energies. The radiation-reaction--dominated…

Plasma Physics · Physics 2015-06-25 T. G. Blackburn

The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams (< 5 MeV/A) the…

Instrumentation and Detectors · Physics 2016-10-12 J. Vadas , Varinderjit Singh , G. Visser , A. Alexander , S. Hudan , J. Huston , B. B. Wiggins , A. Chbihi , M. Famiano , M. M. Bischak , R. T. deSouza

Ultra-high dose rate electron sources require dose rate independent dosimeters and a calibrated dose control system for accurate delivery. In this study, we developed a single-pulse dose monitoring and a real-time dose-based control system…