English

A beam-driven proton irradiation setup for precision radiation damage tests of silicon detectors

Instrumentation and Detectors 2024-05-07 v3

Abstract

A proton irradiation site for silicon detectors has been developed and commissioned at the Bonn Isochronous Cyclotron. The accelerator provides 14 MeV proton beams of up to 1 μ\muA at beam widths of a few mm to the setup. Devices Under Test (DUTs) are irradiated inside a cooled, thermally-insulated box at \le-20{\deg}C, while being moved through the beam in a row-based scan pattern to achieve uniform fluence distributions. Custom-made diagnostics allow for beam-based, on- and offline dosimetry, enabling a beam-driven irradiation routine which produces uniform fluence distributions with standard deviations 1% \ll 1 \% . Dedicated irradiations of thin titanium foils are performed to compare the commonly-used dosimetry via metallic foil activation to the beam-based approach. Within the error margins, both methods are in agreement, whereas the beam-based technique yields lower uncertainties of typically 2% \le 2 \% . Simulations indicate a reduction of the initial proton energy to 12.28(6) MeV on the DUT. Characterization of six, 150 μ\mum-thin, passive LFoundry sensors before and after irradiation yield a proton hardness factor of κp=3.71(11)\kappa_\text{p}=3.71(11), which is in agreement with expectations, allowing to irradiate up to 1016neq/cm210^{16} \text{n}_{eq} / \text{cm}^2 within a few hours.

Keywords

Cite

@article{arxiv.2404.11192,
  title  = {A beam-driven proton irradiation setup for precision radiation damage tests of silicon detectors},
  author = {Pascal Wolf and Dennis Sauerland and Reinhard Beck and Jochen Dingfelder},
  journal= {arXiv preprint arXiv:2404.11192},
  year   = {2024}
}