Related papers: Parameters for a 30 GeV Undulator Test Facility in…
A high-brilliance ($\sim10^{24}$~photon.s$^{-1}$.mm$^{-2}$.mrd$^{-2}$/0.1\%) gamma-ray source experiment is currently being planned at Fermilab ($E_\gamma\simeq 1.1$~MeV)~[1]. The source implements a high-repetition-rate inverse Compton…
We discuss plans for the E302 instability-efficiency experiment, starting in 2024 at the recently upgraded FACET-II facility at SLAC National Accelerator Laboratory. The beam-breakup instability will be the main area of study for the E302…
The disassembly of the Unilac prestripper linac of the Wideroe type took place at the beginning of 1999. An increase of more than two orders of magnitude in particle number for the most heavy elements in the SIS had to be gained. Since that…
The Fermilab Side-Coupled Linac accelerates H-beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster…
To realize and test advanced accelerator concepts and hardware, a beamline is being reconfigured in the Linac Extension Area (LEA) of APS linac. A photo-cathode RF gun installed at the beginning of the APS linac will provide a low emittance…
Submitted as input for discussions on a possible low emittance muon accumulator at 50 TeV. I present a scheme to obtain high quality positive and negative muon beams in terms of low emittance, high charge and high energy using an…
In NSC KIPT linac, a neutron source based on a subcritical assembly driven by a 100MeV/100kW electron linear accelerator is under design and development. The linear accelerator needs a new high current electron gun. In this paper, the…
In the last ten years the use of proton beams in radiation therapy has become a clinical tool for treatment of deep-seated tumours. LIBO is a RF compact and low cost proton linear accelerator (SCL type) for hadrontherapy. It is conceived by…
It is difficult for us to measure the Booster ring impedance up to the GHz range due to the instrumentation limit. Since the de-bunching process in the Linac to Booster transfer is determined by the complex impedance of the Booster ring,…
A new ion source will be prepared for the CYCLONE30 commercial cyclotron with a much advanced performance compared with the previous one. The newly designed ion source has a very large transparency without deteriorating the beam optics,…
The RF part of the new high current injector-linac HSI consists of five cavities with the new operating frequency of 36 MHz instead of 27 MHz of the removed Wideroe type injector. The calculated power requirements of the cavities including…
The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining…
High harmonic generation by an undulator is a key issue for extending the photon energy range of synchrotron light sources. In this work, we propose a biharmonic planar undulator operating in the low-K regime (K<1) to enhance high-harmonic…
In the framework of the Eupraxia Design Study an advanced accelerator facility EUPRAXIA@SPARC_LAB has been proposed to be realized at Frascati (Italy) Laboratories of INFN. Two advanced acceleration schemes will be applied, namely an…
To date, linear accelerators (linacs) as electron sources used to produce ionizing radiation for industrial purposes have been limited to less than 100 kW. When the electron beam is used directly, this is sufficient for most potential…
PIP-II is the Fermilab's flagship project for providing powerful, high-intensity proton beams to the laboratory's experiments. The heart of PIP-II is an 800-MeV superconducting linac accelerator. It will be located in a new tunnel with new…
A series of Silicon crystal undulator samples were produced based on the approach presented in PRL 90 (2003) 034801, with the periods of undulation from 0.1 mm to 1 mm, and the number of periods on the order of 10. The samples were…
3D Silicon sensors fabricated at FBK-irst with the Double-side Double Type Column (DDTC) approach and columnar electrodes only partially etched through p-type substrates were tested in laboratory and in a 1.35 Tesla magnetic field with a…
Alignment of the ILC main linac will be more critical than for any currently existing accelerators due to its long length and the ultra low emittance required. There are several techniques for measuring the ILC reference network; in this…
Although accelerator technology has matured sufficiently, state-of-the-art X-ray linacs for radiotherapy and cargo-scanning capture merely 30-50% of the electrons from a thermionic cathode, requiring a higher cathode current and leaving…