English
Related papers

Related papers: A Large Area Timing RPC

200 papers

Low radioactive material screening is becoming essential for rare event search experiments, such as neutrinoless double beta decay and dark matter searches in underground laboratories. A gaseous time projection chamber (TPC) can be used for…

Instrumentation and Detectors · Physics 2022-08-08 Haiyan Du , Chengbo Du , Ke Han , Shengming He , Liqiang Liu , Yue Meng , Shaobo Wang , Tao Zhang , Wenming Zhang , Li Zhao , Jifang Zhou

In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…

The Resistive Plate Chamber (RPC) is widely used in experiments of high energy physics as trigger detector as its good time resolution and high efficiency. In the traditional layout of RPC, the graphite layers are indispensable parts. The…

Instrumentation and Detectors · Physics 2021-08-31 Quanyin Li , Xiangyu Xie , Zhengwei Xue , Jiajin Ge , Yongjie Sun

A strip-readout parallel-plate avalanche counter (SR-PPAC) has been developed aiming at the high detection efficiency and good position resolution in high-intensity heavy-ion measurements. The performance was evaluated using 115 MeV/u…

A new Time Projection Chamber (TPC) is currently under development for the sPHENIX experiment at RHIC. The TPC will be read out using multistage GEM detectors on each end and will be divided into approximately 40 pad layers in radius. Each…

Instrumentation and Detectors · Physics 2018-08-15 B. Azmoun , P. Garg , T. K. Hemmick , M. Hohlmann , A. Kiselev , M. L. Purschke , C. Woody , A. Zhang

Keeping in mind the requirements of high rate capable, cost effective, large area detectors to be used in future high energy physics experiments, commercially available bakelite plates having moderate bulk resistivity are used to build an…

Instrumentation and Detectors · Physics 2024-01-25 Arindam Sen , Sayak Chatterjee , Shreya Roy , Saikat Biswas , Supriya Das

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

High Energy Physics - Experiment · Physics 2009-11-10 Kentaro Miuchi , Hidetoshi Kubo , Tsutomu Nagayoshi , Atsuhiko Ochi , Reiko Orito , Atsushi Takada , Toru Tanimori , Masaru Ueno

A prototype of Multi-Wire Proportional Chambers (MWPC) has been fabricated for the study of its various characteristics. The detector contains gold-coated tungsten wires (20 $\mu m$ diameter) on the anode frame, with a pitch of 2.8 mm. The…

Instrumentation and Detectors · Physics 2021-10-06 Rajendra Nath Patra , R. N. Singaraju , S. Biswas , T. K. Nayak , Y. P. Viyogi

The Resistive Plate Chambers (RPC) are low-cost charged-particle detectors with good timing resolution and potentially good spatial resolution. Using RPC as gamma detector provides an opportunity for application in positron emission…

Instrumentation and Detectors · Physics 2014-02-20 Zhou Weizheng , Shao Ming , Li Cheng , Chen Hongfang , Sun Yongjie , Chen Tianxiang

Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…

Instrumentation and Detectors · Physics 2024-01-25 A. Sen , S. Chatterjee , S. Das , S. Biswas

The ALICE Time-Of-Flight (TOF) detector at LHC is based on the Multigap Resistive Plate Chambers (MRPCs). The TOF performance during LHC Run 2 is here reported. Particular attention is given to the improved time resolution reached by TOF…

Instrumentation and Detectors · Physics 2019-07-24 Francesca Carnesecchi

Resistive Plate Chamber (RPC) is a type of gaseous detector having excellent time and position resolutions. VECC is involved in the R\&D of indigenously developed bakelite RPCs. The largest size of bakelite RPC developed in India is 100 cm…

Instrumentation and Detectors · Physics 2016-03-17 R. Ganai , K. Agarwal , A. Roy , B. Muduli , S. Chattopadhyay , Z. Ahammed , G. Das , S. Ramnarayan

A large (240 cm $\times$ 120 cm $\times$ 0.2 cm) oil-free High Pressure Laminate (HPL), commonly referred as "bakelite", Resistive Plate Chamber (RPC) has been developed at VECC-Kolkata using locally available P-302 OLTC grade HPL. The…

Instrumentation and Detectors · Physics 2016-05-25 Rajesh Ganai , Arindam Roy , Kshitij Agarwal , Zubayer Ahammed , Subikash Choudhury , Subhasis Chattopadhyay

During Phase-2 of the LHC, known as the High Luminosity LHC (HL-LHC), the accelerator will increase its instantaneous luminosity to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$, delivering an integrated luminosity of 3000 fb$^{-1}$ over 10 years…

Instrumentation and Detectors · Physics 2020-07-24 Priyanka Kumari

A prototype multiwire proportional chamber (MWPC) was developed to demonstrate the feasibility of constructing a radiopure time projection chamber with MWPC track readout to assay materials for alpha- and beta-emitting surface contaminants…

Instrumentation and Detectors · Physics 2015-06-16 Z. Ahmed , M. A. Bowles , R. Bunker , S. R. Golwala , D. R. Grant , M. Kos , R. H. Nelson , A. Rider , R. W. Schnee , D. Sotolongo , B. Wang , A. Zahn

A comparative measurement of timing properties of magnetic-resistant fine mesh R7761-70 and ordinary fast R2083 photomultipliers is presented together with preliminary results on the operation of R7761-70 PMs in magnetic field up to 1100…

Instrumentation and Detectors · Physics 2009-05-29 V. Kuznetsov , A. Ni , H. S. Dho , J. Jang , A. Kim , W. Kim

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of…

Instrumentation and Detectors · Physics 2021-07-19 R. Abbott , A. Abreu , F. Addesa , M. Alhusseini , T. Anderson , Y. Andreev , A. Apresyan , R. Arcidiacono , M. Arenton , E. Auffray , D. Bastos , L. A. T. Bauerdick , R. Bellan , M. Bellato , A. Benaglia , M. Benettoni , R. Bertoni , M. Besancon , S. Bharthuar , A. Bornheim , E. Brücken , J. N. Butler , C. Campagnari , M. Campana , R. Carlin , P. Carniti , N. Cartiglia , M. Casarsa , O. Cerri , P. Checchia , H. Chen , S. Chidzik , F. Chlebana , F. Cossutti , M. Costa , B. Cox , I. Dafinei , F. De Guio , P. Debbins , D. del Re , A. Dermenev , E. Di Marco , K. Dilsiz , K. F. Di Petrillo , G. Dissertori , S. Dogra , U. Dosselli , I. Dutta , F. Caleb , C. Fernandez Madrazo , M. Fernandez , M. Ferrero , Z. Flowers , W. Funk , M. Gallinaro , S. Ganjour , M. Gardner , F. Geurts , A. Ghezzi , S. Gninenko , F. Golf , J. Gonzalez , C. Gotti , L. Gray , F. Guilloux , S. Gundacker , E. Hazen , S. Hedia , A. Heering , R. Heller , T. Isidori , R. Isocrate , R. Jaramillo , M. Joyce , K. Kaadze , A. Karneyeu , H. Kim , J. King , G. Kopp , M. Korjik , O. K. Koseyan , A. Kozyrev , N. Kratochwil , M. Lazarovits , A. Ledovskoy , H. Lee , J. Lee , A. Li , S. Li , W. Li , T. Liu , N. Lu , M. Lucchini , W. Lustermann , C. Madrid , M. Malberti , I. Mandjavize , J. Mao , Y. Maravin , D. Marlow , B. Marsh , P. Martinez del Arbol , B. Marzocchi , R. Mazza , C. McMahon , V. Mechinsky , P. Meridiani , A. Mestvirishvili , N. Minafra , A. Mohammadi , F. Monti , C. S. Moon , R. Mulargia , M. Murray , Y. Musienko , J. Nachtman , S. Nargelas , L. Narvaez , O. Neogi , C. Neu , T. Niknejad , M. Obertino , H. Ogul , G. Oh , I. Ojalvo , Y. Onel , G. Organtini , T. Orimoto , J. Ott , I. Ovtin , M. Paganoni , F. Pandolfi , R. Paramatti , A. Peck , C. Perez , G. Pessina , C. Pena , S. Pigazzini , O. Radchenko , N. Redaelli , D. Rigoni , E. Robutti , C. Rogan , R. Rossin , C. Rovelli , C. Royon , M. Ö. Sahin , W. Sands , F. Santanastasio , U. Sarica , I. Schmidt , R. Schmitz , J. Sheplock , J. C. Silva , F. Siviero , L. Soffi , V. Sola , G. Sorrentino , M. Spiropulu , D. Spitzbart , A. G. Stahl Leiton , A. Staiano , D. Stuart , I. Suarez , T. Tabarelli de Fatis , G. Tamulaitis , Y. Tang , B. Tannenwald , R. Taylor , E. Tiras , M. Titov , S. Tkaczyk , D. Tlisov , I. Tlisova , M. Tornago , M. Tosi , R. Tramontano , J. Trevor , C. G. Tully , B. Ujvari , J. Varela , S. Ventura , I. Vila , T. Wamorkar , C. Wang , X. Wang , M. Wayne , J. Wetzel , S. White , D. Winn , S. Wu , S. Xie , Z. Ye , G. B. Yu , G. Zhang , L. Zhang , Y. Zhang , Z. Zhang , R. Zhu

A large volume Time Projection Chamber (TPC) has been proposed as main tracking device at the International Linear Collider (ILC). Gas electron multipliers (GEMs) are studied as potential replacement of the conventional wire based gas…

Instrumentation and Detectors · Physics 2007-05-23 Peter Wienemann

We report on the development of a large-volume, wide field-of-view time projection chamber (TPC) for X-ray polarimetry, featuring a triple-GEM amplification stage and optical readout. Originally developed within the CYGNO program for…

Several high energy physics and neutrino physics experiments worldwide require large-size RPCs to cover wide acceptances. The muon tracking systems in the Iron calorimeter (ICAL) in the INO experiment, India and the near detector in DUNE at…

‹ Prev 1 3 4 5 6 7 10 Next ›