English
Related papers

Related papers: Beam Profile Monitors in the Nlcta

200 papers

The NLC extraction line provides a secondary focal point with a low beta function and 2 cm dispersion which can be used for measurement of the beam energy spectrum. In this study, tracking simulations were performed to transport the 0.5 TeV…

Accelerator Physics · Physics 2008-11-26 Y. Nosochkov , T. O. Raubenheimer

An electron lens is planned for the Fermilab Integrable Optics Test Accelerator as a nonlinear element for integrable dynamics, as an electron cooler, and as an electron trap to study space-charge compensation in rings. We present the main…

Accelerator Physics · Physics 2015-11-17 Daniel Noll , Giulio Stancari

Fine pixel CCD (FPCCD) is an option for the sensor used for the ILC vertex detector to reduce the pixel occupancy due to the high background rate near the interaction point. In this paper, we report on the R&D status of FPCCD sensors and…

Instrumentation and Detectors · Physics 2010-07-16 Yasuhiro Sugimoto , Hirokazu Ikeda , Kennosuke Itagaki , Akiya Miyamoto , Yousuke Takubo , Hitoshi Yamamoto

A conceptual program to use NLC beams for test beams and fixed target physics is described. Primary undisrupted polarized beams would be the most simple to use, but for NLC, the disrupted beams are of good enough quality that they could…

Accelerator Physics · Physics 2009-11-07 Lewis Keller , Rainer Pitthan , Sayed Rokni , Kathleen Thompson , Yury Kolomenski

The MTA beam line has been specifically designed to facilitate measurements of the Fermilab Linac beam emittance and properties utilizing a long, 10m, element-free straight. Linac beam is extracted downstream of the 400-MeV electrostatic…

Accelerator Physics · Physics 2012-09-26 C. Johnstone

The beam-profile diagnostics station prototype for the superconducting rf electron linac being constructed at Fermilab at the New Muon Lab has been tested. The station uses intercepting radiation converter screens for the low-power beam…

Accelerator Physics · Physics 2012-08-22 A. Lumpkin , R. Flora , A. S. Johnson , J. Ruan , J. Santucci , V. Scarpine , Y. -E. Sun , R. Thurman-Keup , M. Church , M. Wendt

Laser plasma accelerators have the potential to reduce the size of future linacs for high energy physics by more than an order of magnitude, due to their high gradient. Research is in progress at current facilities, including the BELLA…

Accelerator Physics · Physics 2013-10-01 C. G. R. Geddes , J. -L. Vay , C. B. Schroeder , E. Esarey , W. P. Leemans

This study focuses on implementing a real-time control system for a particle accelerator facility that performs high energy physics experiments. A critical operating parameter in this facility is beam loss, which is the fraction of…

Non-Intrusive Load Monitoring (NILM) identifies the operating status and energy consumption of each electrical device in the circuit by analyzing the electrical signals at the bus, which is of great significance for smart power management.…

Machine Learning · Computer Science 2025-06-10 Olimjon Toirov , Wei Yu

This article develops the applicability of non-linear processing techniques such as Compressed Sensing (CS), Principal Component Analysis (PCA), Iterative Adaptive Approach (IAA) and Multiple-input-multiple-output (MIMO) for the purpose of…

Signal Processing · Electrical Eng. & Systems 2023-03-27 Mohit Kumar , Keith Kelly

The state of charge (SoC) and the rate of charging/discharging current are the vital parameters associated with a battery by which its accurate runtime can be estimated. This paper aims to design a controller which comprises of a…

Signal Processing · Electrical Eng. & Systems 2020-05-26 P. Dinesh , K. Kumar Teja , Shashank Singh , Selvan M. P. , Moorthi S

Imaging systems have been an integral part of many beam monitors since the early days of accelerator diagnostics. The main application remains the observation of scintillating screens during commissioning, alignment and routine operation…

Accelerator Physics · Physics 2020-05-12 B. Walasek-Hoehne , K. Hoehne , R. Singh

Fault injections are increasingly used to attack/test secure applications. In this paper, we define formal models of runtime monitors that can detect fault injections that result in test inversion attacks and arbitrary jumps in the control…

Cryptography and Security · Computer Science 2019-09-23 Ali Kassem , Yliès Falcone

Beam loss (BLM) and beam current monitors (BCM) are ubiquitous at particle accelerator around the world. These simple devices provide non-invasive high level beam measurements, but give no insight into the detailed 6D (x,y,z,px,py,pz) beam…

Accelerator Physics · Physics 2025-02-27 Alexander Scheinker , Alan Williams

NOvA is a long-baseline neutrino oscillation experiment. It uses the NuMI beam from Fermilab and two sampling calorimeter detectors located off-axis from the beam. The NOvA experiment measures the rate of electron-neutrino appearance in the…

Instrumentation and Detectors · Physics 2017-10-12 Biswaranjan Behera

In this report the test beam requirements for the vertex detector and the tracking detector for ILC are discussed. It focuses on the infrastructure needs of the different subsystems. In the second part of this summary the ideas about future…

Instrumentation and Detectors · Physics 2009-01-16 Ingrid-Maria Gregor

A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre / \textit{Heidelberg Ionenstrahl Therapiezentrum} (HIT) in 2016 to determine its beam property reconstruction performance and…

Instrumentation and Detectors · Physics 2018-06-27 B. D. Leverington , M. Dziewiecki , L. Renner , R. Runze

One of the optimization goals of a particle accelerator is to reach the highest possible beam peak current. For that to happen the electron bunch propagating through the accelerator should be kept relatively short along the direction of its…

Instrumentation and Detectors · Physics 2018-06-28 Aleksander Mielczarek , Dariusz Makowski , Andrzej Napieralski , Christopher Gerth , Bernd Steffen

Many types of neutron spectrometer use a conventional primary spectrometer consisting of some collimator, a crystal monochromator and a second collimator. Conventional resolution descriptions use instrument parameter values to deduce the…

Instrumentation and Detectors · Physics 2016-06-21 Leo D. Cussen