English
Related papers

Related papers: Beam Profile Monitors in the Nlcta

200 papers

A 'plasma lens' might be used to enhance the luminosity of future linear colliders. However, its utility for this purpose depends largely on the potential backgrounds that may be induced by the insertion of such a device in the interaction…

High Energy Physics - Experiment · Physics 2009-11-07 Achim W. Weidemann , Pisin Chen , Cho-Kuen Ng

We outline the design of beam experiments for the electron linac at the Fermilab Accelerator Science and Technology (FAST) facility and for the Integrable Optics Test Accelerator (IOTA), based on synchrotron light emitted by the electrons…

Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. However, if…

Instrumentation and Detectors · Physics 2011-10-17 R. Thurman-Keup , H. W. K. Cheung , A. Hahn , P. Hurh , E. Lorman , C. Lundberg , T. Meyer , D. Miller , S. Pordes , A. Valishev

An instrument has been developed for precision controlled exposures of electronic devices and material samples in particle beams. The instrument provides simultaneously a real time record of the profile of the beam and the fluence received.…

Instrumentation and Detectors · Physics 2020-12-03 M. R. Hoeferkamp , J. S. T. Wickramasinghe , A. Grummer , I. Rajen , S. Seidel

The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such…

Accelerator Physics · Physics 2015-11-09 R. Thurman-Keup , M. Alvarez , J. Fitzgerald , C. Lundberg , P. Prieto , M. Roberts , J. Zagel , W. Blokland

Neutron beam monitors with high efficiency, low gamma sensitivity, high time and space resolution are required in neutron beam experiments to continuously diagnose the delivered beam. In this work, commercially available neutron beam…

Instrumentation and Detectors · Physics 2017-10-04 F. Issa , A. Khaplanov , R. Hall-Wilton , I. Llamas , M. Dalseth Riktor , S. R. Brattheim , H. Perrey

Ionization profile monitors (IPMs) are used in the Fermilab Main Injector (MI) to monitor injection lattice matching by measuring turn-by-turn sigmas at injection and to measure transverse emittance of the beam during the acceleration…

A new detector is being developed at the National Superconducting Cyclotron Laboratory (NSCL) to measure low energy charged-particles from beta-delayed particle emission. These low energy particles are very important for nuclear…

Instrumentation and Detectors · Physics 2016-06-27 D. Perez-Loureiro , C. Wrede

Beam diagnostics and instrumentation are an essential part of any kind of accelerator. There is a large variety of parameters to be measured for observation of particle beams with the precision required to tune, operate, and improve the…

Accelerator Physics · Physics 2020-05-19 Gero Kube

Beam position monitors (BPMs) are indispensable components of modern particle accelerators, providing real-time diagnostics to ensure precise beam control, stability, and quality. As accelerators such as the International Linear Collider…

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…

The Integrable Optics Test Accelerator (IOTA) at the Fermilab Accelerator Science & Technology (FAST) Facility is beginning operations, with an experimental program aimed at developing technology to enable future high intensity particle…

Accelerator Physics · Physics 2019-03-15 Ben Freemire , Jeffrey Eldred

At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional…

Accelerator Physics · Physics 2016-12-20 A. L. Edelen , S. G. Biedron , S. V. Milton , J. P. Edelen

A scintillating-fiber beam profile detector has been designed, built and tested, for the monitoring of the position and size of the electron beam of the DAFNE, the recently commissioned electron beam-test facility at the Frascati LNF. A…

Instrumentation and Detectors · Physics 2007-05-23 M. Anelli , B. Buonomo , G. Mazzitelli , P. Valente

At the international linear collider, measurement of the beam profile at the interaction point is a key issue to achieve high luminosity. We report a simulation study on a new beam profile monitor, called the pair monitor, which uses the…

Instrumentation and Detectors · Physics 2015-05-13 Kazutoshi Ito , Akiya Miyamoto , Tadashi Nagamine , Toshiaki Tauchi , Hitoshi Yamamoto , Yosuke Takubo , Yutaro Sato

In superconducting linear accelerators (linacs), accurately monitoring beam dynamics is essential for minimizing beam losses and ensuring stable operations. However, destructive diagnostics must be avoided in superconducting sections to…

The beam calorimeter, located in the very forward and backward region of the next generation electron-positron linear accelerator, will be an important apparatus to search for or identify new particles beyond Standard Model. One of its key…

Instrumentation and Detectors · Physics 2009-02-19 S. -X. Huang , M. -C. Chang , M. -Z. Wang

The transverse emittance of a charged particle beam is an important figure of merit for many accelerator applications, such as ultra-fast electron diffraction, free electron lasers and the operation of new compact accelerator concepts in…

Accelerator Physics · Physics 2022-09-21 F. Mayet , M. Hachmann , K. Floettmann , F. Burkart , H. Dinter , W. Kuropka , T. Vinatier , R. Assmann

Feedback systems are essential for stable operation of a linear collider, providing a cost-effective method for relaxing tight tolerances. In the Stanford Linear Collider (SLC), feedback controls beam parameters such as trajectory, energy,…

Accelerator Physics · Physics 2016-11-17 L. Hendrickson , P. Grossberg , T. Himel , M. Minty , N. Phinney , P. Raimondi , T. Raubenheimer , H. Shoaee , P. Tenenbaum

We report the initial considerations of using linearly polarized optical transition radiation (OTR) to characterize the electron beams of laser plasma accelerators (LPAs) such as at the Univ. of Texas at Austin. The two LPAs operate at 100…

Accelerator Physics · Physics 2018-05-14 A. H. Lumpkin , D. W. Rule , M. C. Downer