Related papers: A working with a Silicon Position Sensitive Detect…
Determination of the path taken by a quantum particle leads to a suppression of interference and to a classical behavior. We employ here a quantum 'which path' detector to perform accurate path determination in a…
Searches for signals of new physics in particle physics are usually done by training a supervised classifier to separate a signal model from the known Standard Model physics (also called the background model). However, even when the signal…
We present results on the reconstructed image resolution of a position sensitive radiation instrument (COCAE) based on extensive simulation studies. The reconstructed image resolution has been investigated in a wide range of incident photon…
Silicon-based photonic biosensors, such as microring resonators and Mach-Zehnder interferometers, offer significant potential for the detection of analytes at low concentrations. To enhance response time and improve the limit of detection…
A method is proposed and experimentally explored for in-situ calibration of complex transmission data for superconducting microwave resonators. This cryogenic calibration method accounts for the instrumental transmission response between…
Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector's resolution is larger than the energy of a single photon, a…
To test and calibrate various detectors in nuclear and high energy physics experiments, a general purposed calibration instrument has been developed. All information including timing, amplitude and charge of signals can be directly obtained…
We describe DSiD, a fast simulation Delphes detector for the International Linear Collider (ILC) based on the full simulation performance of the SiD detector. SiD is one of two detectors described in the ILC Technical Design Report (TDR).…
The Linear Collider TPC collaboration constructed a Large Prototype TPC (LPTPC) which is now installed at the EUDET facility, in DESY. The SiLC-collaboration (Silicon for the Linear Collider) will install position sensitive silicon strip…
The BABAR Silicon Vertex Tracker (SVT) is a five-layer double-sided silicon detector designed to provide precise measurements of the position and direction of primary tracks, and to fully reconstruct low-momentum tracks produced in e+e-…
Simulation studies and spectroscopic measurements are presented regarding the development of a pixel multilayer CdTe detector under development in the context of the COCAE project. The instrument will be used for the localization and…
This study provides a computationally effective deconvolution algorithm capable to reconstruct piled-up events in scintillating detector systems with high count rate where fully digitized waveforms are available. A fixed-point iteration…
This work presents a suite of measurement techniques for characterizing the dielectric loss tangent across a wide frequency range from $\sim$1 GHz to 150 GHz using the same test chip. In the first method, we fit data from a microwave…
Silicon detectors typically require an insensitive area around their periphery to accommodate guard rings, which help maintain the electric field uniformity around edge pixels and isolate the high leakage current from the physical edges of…
The physics aims at the proposed future high-energy linear $e^+e^-$ collider CLIC pose challenging demands on the performance of the detector system. In particular, the vertex and tracking detectors have to combine a spatial resolution of a…
Pipelined analog-to-digital converters (ADCs) are fundamental components of various signal processing systems requiring high sampling rates and a high linearity. Over the past years, calibration techniques have been intensively investigated…
The Silicon Electron Multiplier (SiEM) sensor is a novel sensor concept that enables charge multiplication by high electric fields generated by embedded metal electrodes within the sensor bulk. Metal assisted chemical etching (MacEtch) in…
Excellent jet energy measurement is important at the International Linear Collider (ILC) because most of interesting physics processes decay into multi-jet final states. We employ a particle flow method to reconstruct particles, hence…
A mechanical electroscope based on a change in the resonant frequency of a cantilever one micron in size in the presence of charge has recently been fabricated. We derive the decoherence rate of a charge superposition during measurement…
We demonstrate a direct-detection phase retrieval receiver based on silicon photonics. The receiver implements strong dispersion and delay lines on a compact chip. We retrieve the full field of a 30-GBd QPSK signal without a carrier or…